37-033-26199

Well Details

Well ID: 37-033-26199
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Bloom Township
Operator Name: VEC ENERGY LLC
Well Pad ID:
Farm/Lease Name: LANAGER 3
License Status: ACTIVE
Spud Date:
Permit Date: 2006-09-21
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.035125
Longitude: -78.650811

For data sources see[1][2][3]

Well History

Date Event
2006-09-21 New Permit Application
2006-12-07 Performed Spud Operation
2006-12-12 Drilling Completion
2006-12-26 Perforation
2007-08-31 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2006 VICTORY ENERGY CORP 0.00 0 0.00 0 0.00 0
2007 VICTORY ENERGY CORP 2215 235 0.00 0 0.00 0
2008 VICTORY ENERGY CORP 1049.57 104 0.00 0 0.00 0
2009 VICTORY ENERGY CORP 1721.54 177 0.00 0 0.00 0
2010 VICTORY ENERGY CORP 1,893.18 326 0.00 0 0.00 0
2011 VICTORY ENERGY CORP 1,830.38 311 0.00 0 0.00 0
2012 VICTORY ENERGY CORP 1,303.14 249 0.00 0 0.00 0
2013 VICTORY ENERGY CORP 1,282.50 319 0.00 0 0.00 0
2014 VICTORY ENERGY CORP 1,189.91 346 0.00 0 0.00 0
2015 VICTORY ENERGY CORP 1,313.09 326 0.00 0 0.00 0
2016 VICTORY ENERGY CORP 1,082.43 351 0.00 0 0.00 0
2017 VICTORY ENERGY CORP 1,331.00 326 0.00 0 0.00 0
2018 VEC ENERGY LLC 708.00 365 0.00 0 0.00 0
2019 VEC ENERGY LLC 236.00 363 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2008 VICTORY ENERGY CORP Brine 80.00 Bbl Brine or Industrial Waste Treatment Plt PA0095273
2009 VICTORY ENERGY CORP Brine 360.00 Bbl Road Spreading
2010 VICTORY ENERGY CORP Produced Fluid 100.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2010 VICTORY ENERGY CORP Produced Fluid 240.00 Bbl Road Spreading
2012 VICTORY ENERGY CORP Produced Fluid 190.00 Bbl Road Spreading
2013 VICTORY ENERGY CORP Produced Fluid 100.00 Bbl Road Spreading
2015 VICTORY ENERGY CORP Produced Fluid 100.00 Bbl Road Spreading

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2571706 Primary Facility 2017-03-15 Routine/Complete Inspection No Violations Noted Site inspection of a conventional gas well that is identified in the Department's EFACTS database as having been spudded but not previously inspected by the Department. The Lanager #3 well was spudded on 12/7/2006. The wellhead plumbing and production configuration is essentially identical for the (3) wells on the Lanager lease inspected today.
    Well API/Permit # posted on wellhead tag.  Production gas is directed via a 2" line off the 4 1/2" production casing string and then sequentially through a standard production fluids separator unit, line drip, and orifice meter/chart recorder to the 2" gathering pipeline riser.  A tubing string (~1") is hung inside the production casing string, and a gasoline powered pump jack is rigged to the tubing head for removal of excess downhole fluids. Pump jack unit is mounted on concrete base pads, and spotted inside a cyclone fence enclosure. Tubing fluids discharge is plumbed via 2" piping directly off the tubing head to (2) 100 bbl. poly fluids tanks, that are manif

For data sources see[7]

References