37-023-20134

Well Details

Well ID: 37-023-20134
Loading map...
Country: United States
State: Pennsylvania
County: Cameron
Municipality: Shippen Township
Operator Name: SAMSON EXPLORATION LLC
Well Pad ID: 149006
Farm/Lease Name: PARDEE & CURTIN LUMBER CO
License Status: Plugged and Abandoned
Spud Date: 2010-11-23
Permit Date: 2010-09-02
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.445322
Longitude: -78.226964

For data sources see[1][2][3]

Well History

Date Event
2010-09-02 New Permit Application
2010-11-23 Performed Spud Operation
2011-01-31 Drilling Completion
2011-09-19 Deviated
2016-04-14 Inactive Well Request Granted
2017-07-12 Begin Plugging
2017-11-14 Finished Plugging

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-09-02 2011-09-02 6,678 4,871,748

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 InFlo 250 Baker Hughes Surfactant Surfactants 80.00 0.00113000
2-Butoxyethanol 111-76-2 20.00 0.00028000
Sand, White, 40/70 Baker Hughes Proppant Quartz 14808-60-7 100.00 8.28
Alpha 1427 Baker Hughes Biocide Didecyl dimethyl ammonium chloride 7173-51-5 10.00 0.00114000
Water 7732-18-5 60.00 0.00681000
Glutaraldehyde 111-30-8 30.00 0.00341000
Ethanol 64-17-5 5.00 0.00057000
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 7.00 0.00079000
CI-14 Baker Hughes Corrosion Inhibitor Propargyl alcohol 107-19-7 5.00 0.00006000
Fatty Acids 10.00 0.00012000
Methanol 67-56-1 100.00 0.00122000
Olefin 5.00 0.00006000
Polyoxyalkylenes 30.00 0.00036000
Ferrotrol 300L Baker Hughes Iron Control Citric acid 77-92-9 70.00 0.00739000
Scaletrol 720 Baker Hughes Scale Inhibitor Diethylene glycol 111-46-6 5.00 0.00102000
Ethylene glycol 107-21-1 45.00 0.00920000
Hydrochloric Acid 5.1-7.5 Baker Hughes Acidizing Water 7732-18-5 93.00 1.50
Hydrochloric acid 7647-01-0 8.00 0.12
Water Operator Carrier Water 7732-18-5 100.00 87.21
FRW-18 Baker Hughes Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Sand, White, 100 mesh Baker Hughes Proppant Quartz 14808-60-7 100.00 2.80

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 J W OPERATING CO 0.00 0 0.00 0 0.00 0
2011 J W OPERATING CO 0.00 0 0.00 0 0.00 0
2012 ENDEAVOUR OPERATING CORP 0.00 0 0.00 0 0.00 0
2013 ENDEAVOUR OPERATING CORP 0.00 0 0.00 0 0.00 0
2014 SAMSON EXPLORATION LLC 0.00 0 0.00 0 0.00 0
2015 SAMSON EXPLORATION LLC 0.00 0 0.00 0 0.00 0
2016 SAMSON EXPLORATION LLC 0.00 0 0.00 0 0.00 0
2017 SAMSON EXPLORATION LLC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 J W OPERATING CO Fracing Fluid Waste 19,317.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 J W OPERATING CO Produced Fluid 0.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2017 SAMSON EXPLORATION LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1922980 Primary Facility 2010-10-27 Compliance Evaluation No Violations Noted
1926487 Primary Facility 2010-11-09 Compliance Evaluation No Violations Noted
1928116 Primary Facility 2010-11-17 Follow-up Inspection No Violations Noted
1931535 Primary Facility 2010-11-30 Drilling/Alteration Viol(s) Noted & Immediately Corrected
1933500 Primary Facility 2010-12-08 Drilling/Alteration No Violations Noted
1934400 Primary Facility 2010-12-15 Drilling/Alteration No Violations Noted
1938284 Primary Facility 2010-12-21 Drilling/Alteration No Violations Noted
1940039 Primary Facility 2010-12-31 Drilling/Alteration No Violations Noted
1975426 Primary Facility 2011-05-24 Compliance Evaluation No Violations Noted
1989504 Primary Facility 2011-07-20 Compliance Evaluation No Violations Noted
2073222 Primary Facility 2012-06-05 Routine/Complete Inspection Pending
2074807 Primary Facility 2012-06-11 Follow-up Inspection Violation(s) Noted
2085685 Primary Facility 2012-07-24 Follow-up Inspection No Violations Noted
2104677 Primary Facility 2012-10-03 Routine/Complete Inspection No Violations Noted
2116044 Primary Facility 2012-11-15 Routine/Complete Inspection No Violations Noted
2116046 Primary Facility 2012-11-15 Routine/Complete Inspection No Violations Noted
2134466 Primary Facility 2013-01-30 Routine/Complete Inspection No Violations Noted
2269409 Primary Facility 2014-05-07 Routine/Complete Inspection No Violations Noted
2321270 Primary Facility 2014-11-12 Routine/Complete Inspection No Violations Noted
2339711 Primary Facility 2015-01-23 Routine/Complete Inspection No Violations Noted At the time of inspection cloudy sky, snow cover and 25 degrees F.
2344068 Primary Facility 2015-02-12 Routine/Complete Inspection No Violations Noted At the time of inspection sunny sky, ~20” snow cover and ~30° F.
2346405 Primary Facility 2015-02-24 Routine/Complete Inspection No Violations Noted
2351153 Primary Facility 2015-03-10 Routine/Complete Inspection No Violations Noted
2352091 Primary Facility 2015-03-16 Routine/Complete Inspection No Violations Noted
2373912 Primary Facility 2015-05-28 Routine/Complete Inspection No Violations Noted
2386646 Primary Facility 2015-07-08 Routine/Complete Inspection No Violations Noted
2407241 Primary Facility 2015-09-03 Routine/Complete Inspection No Violations Noted
2465954 Primary Facility 2016-03-16 Routine/Complete Inspection No Violations Noted
2583964 Primary Facility 2017-04-12 Routine/Complete Inspection No Violations Noted On April 12, 2017 I conducted I routine (pre-plugging) inspection on Samson’s 2H, 3H, 12H, 13H, and C5 on the Pardee and Curtin Lumber Co. lease in Cameron county with Jerry Worsham of Samson to check pressures on the wells before plugging to evaluate how each well will need to be addressed in a proposed plugging procedure. The 12H and 13H had no major issues observed during the inspection. The 2H and 3H were bubbling in the cellar (violations pending post-plugging evaluation). No violations were noted on the C5, which was bubbling last inspection turned out to be an open vent that was underwater for backside of production casing. I put a gauge on the vent; no pressure, less than a trace of flow.
2616551 Primary Facility 2017-07-18 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of the Pardee C-12H conducted July 18, 2017 at 11:30 am. Rig is on location for plugging ops. CIBP and cement plug set in production casing. Production casing not recoverable. They perf’d at 1600’ and pressured up to 2500 PSI, could not get injection. Tried again at 1590’, 1580’, could not inject. Talked to operator about plan going forward. They’ll set a balanced plug across the perfs, then perforate at 1140’ and try to get injection rate. If successful they’ll pump a straight well-lock resin squeeze at this interval.
2624251 Primary Facility 2017-08-09 Plugging(Includes Plugged/Mined Through) Pending Inspection of the Pardee 2H conducted August 9, 2017 at 11 am. Rig is on location for plugging ops. The rig could not get injection behind production casing, even after last attempt to break circulation around packer set between sets of perfs. Packer is currently stuck in production casing. After they fish the packer out they will proceed to mill window across shoe and set balanced plug out to formation. I checked the 12H and 13H, the two wells the plugging rig skidded from. The 12H was venting gas, inflated balloon and exceeded 5” manometer water differential reading. The 13H was open to balloon, no inflation or flow observed.
2629289 Primary Facility 2017-08-23 Plugging(Includes Plugged/Mined Through) No Violations Noted Backside of production csg is venting after plugging ops. Installed 160# gauge, waited 30 min, saw no buildup on gauge. Pressure exceeds limit of manometer w/ 10" water differential
2635857 Primary Facility 2017-09-13 Plugging(Includes Plugged/Mined Through) Pending Well is capped, 9x5 annulus is open and venting. There was audible bubbling in the vent pipe. Altair 5x Gas meter confirms 100% methane.
2638966 Primary Facility 2017-09-19 Routine/Complete Inspection No Violations Noted Routine site inspection of Samson Exploration Pardee Curtain Pad E on September 19, 2017. No one was onsite during my inspection. The four wells on this pad have been recently plugged. The wells remain in an observation phase. The wells are not deemed plugged officially until the Department issues a plugging certificate. Well 023-21034 has some bubbling occurring within the well cellar (see picture). Joe Gaboff with the Department is over seeing the plugging operation and I will be referring the issue to Mr. Gaboff for further investigation.

Miscellaneous equipment from the plugging operation remains onsite. Some of the BMPs for site restoration have been installed.

2639976 Primary Facility 2017-09-25 Plugging(Includes Plugged/Mined Through) Pending Cellar full of water. Backside of production casing open and venting below water, bubbling. Rig is on other pad, operator intends to return to this well to remediate and complete P&A.
2663581 Primary Facility 2017-11-22 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine inspection of 4 plugged wells. Rig off location following remediation of the #12 to address annular venting. At the time of inspection this well had a 2" candy cane. No venting was observed, and there was no gas was detected with an altair 5x gas meter at the vent. The other 3 wells all had vent pipes as well, and no gas was detected. No obvious concerns were observed.
2663585 Primary Facility 2017-11-21 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine inspection of 4 plugged wells. Rig off location following remediation of the #12 to address annular venting. At the time of inspection this well had a 2" candy cane. No venting was observed, and there was no gas was detected with an altair 5x gas meter at the vent. The other 3 wells all had vent pipes as well, and no gas was detected. No obvious concerns were observed.
2670218 Primary Facility 2017-12-08 Administrative/File Review No Violations Noted December 13, 2017: Certificate of Well Plugging for the Pardee and Curtin Lumber Co C-12H (023-20134) received, reviewed, signed, and sent to file.
2696017 Primary Facility 2018-02-20 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine inspection of (4) plugged wells on pad. All four wells had 2" candy cane vent pipes erected as well monuments. No obvious integrity issues were observed.

All four wells need to be marked with permit number in accordance with 25 PA Code Chapter 78.97

2721410 Primary Facility 2018-04-23 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine inspection of four plugged unconventional wells on the Pardee and Curtin Lumber C12 pad was conducted April 23, 2018. At the time of inspection, the 12H, 13H, 2H and 3H all had 2" candy cane vent pipes with marker sign erected as a plugged well monument. No visible or audible flow was observed at the vents. All casings are below grade and the pad is reclaimed. No obvious major issues were onserved at this time.
2745010 Primary Facility 2018-05-29 Routine/Complete Inspection No Violations Noted Routine site inspection at Pardee & Curtin Pad E on May 22, 2018 with Michale Race and Joe Kunst of ARM Group and Steve Trujilo of Samson. Samson requested an inspection to evaluate the vegetation status and whether the site meets the requirements for a notice of termination. A few bare spots were observed with little vegetation, but overall the site meets 70% vegetative cover. All run-off from the site is being directed towards the wetland as designed by the restoration plans. I recommend, pulling the skin off the compost sock and spreading the mulch prior to submitting the notice of termination for ESX10-023-0001. The Department recommends submitting as built drawings with the notice of termination.

All four Marcellus wells have been plugged. Each well monument is tagged. A

No violations noted.

2759701 Primary Facility 2018-08-01 Routine/Complete Inspection No Violations Noted On behalf of Samson Exploration, ARM Group Inc. has submitted a notice of termination (NOT) for Pardee Curtin CO C-12 (Well Pad E) covered under ESX10-023-0001. The Department received this NOT on July 16, 2018.

On August 1, 2018 Department representative Sue Herzing conducted a restoration inspection at the above listed site with Steve Trujilo of Samson Exploration and Joe Kunst of ARM Group. The well pad has been restored back to approximate original contours. All run-off from the site is being directed towards the wetland. We walked throughout the restored well pad during the site inspection. Overall the site exceeds 70% uniform, perennial, vegetative cover. All temporary E&S controls have been removed.

Four Marcellus wells have been plugged (023-20134, 023-20135, 023-20185, and 023-20186). Each well is represented by a tagged well monument. Post plugging site restoration reports have been submitted for the above listed wells.

Per this inspection, I hereby approve the NOT for ESX10-023-0001 and the p

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1931535 600618 11/30/2010 2010-11-30 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety
2074807 641326 06/11/2012 2012-06-11 401CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
2074807 641327 06/11/2012 2012-06-11 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
641326 284677 NOV - Notice of Violation Comply/Closed 2012-11-19
641326 290641 CACP - Consent Assessment of Civil Penalty Comply/Closed 2012-11-19 2012-11-19 $27,059.00 $27,059.00
641327 284677 NOV - Notice of Violation Comply/Closed 2012-11-19
641327 290641 CACP - Consent Assessment of Civil Penalty Comply/Closed 2012-11-19 2012-11-19 $27,059.00 $27,059.00

For data sources see[8]

References