37-015-23306

Well Details

Well ID: 37-015-23306
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Leroy Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 146000
Farm/Lease Name: YODER UNIT 3H
License Status:
Spud Date:
Permit Date: 2017-03-16
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.679064
Longitude: -76.675158

For data sources see[1][2][3]

Well History

Date Event
2017-03-16 New Permit Application
2017-04-28 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-10-16 2017-10-22 7,109 5,987,860 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Unislick ST-50 CESI Chemical Friction Reducer Listed Below
Ethoxylated (C10-16) alcohols 68002-97-1 35 0.00006000 35
Acetophenone 98-86-2 1 0.00001000 1
Thiourea 62-56-6 1 0.00001000 1
Ammonium acetate 631-61-8 13 0.00838 4835
Crystallilne silica 14808-60-7 100 13.0604 7,532,300.0
Ethanol, 2,2',2"-nitrilotris-,
tris(dihydrogen phosphate) (ester), sodium salt
68171-29-9 30 0.00168 971
Ethylene glycol 107-21-1 30 0.00168 971
Quaternary ammonium compound 68424-85-1 10 0.00256 1475
Alcohols, C12-16, ethoxylated 68551-12-2 5 0.00322 1860
Water 7732-18-5 100 86.6415 49,968,700.0
Glutaraldehyde 111-30-8 5 0.00128 738
Ethanol 64-17-5 5 0.00128 738
Formaldehyde 50-00-0 1 0.00001000 1
Methanol 67-56-1 5 0.00001000 5
Water 7732-18-5 80 0.02047 11803
Alcohols, C12-14, ethoxylated 68439-50-9 5 0.00322 1860
Distillate, petroleum, hydrotreated, light 64742-47-8 30 0.01935 11158
Diethylene glycol mono-n-butyl ether 112-34-5 60 0.0001 59
Water 7732-18-5 85 0.1719 99137
Alcohols, (C10-16), ethoxylated 68002-97-1 5 0.00322 1860
Hydrochloric acid 7647-01-0 15 0.03033 17495
Water 7732-18-5 40 0.00225 1295
Unihib G GeoSafe Acid Inhibitor Listed Below
SCAL16484A Nalco Champion Scale Inhibitor Listed Below
Hydrochloric Acid PVS Acidizing Listed Below
Sand Sargent/Unimin Proppant Listed Below
BIOC11139A Nalco Champion Biocide Listed Below
Water Chief Oil & Gas Carrier/Base Fluid Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 CHIEF OIL & GAS LLC 358,428.11 58 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 1,186,707.94 363 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 718,157.02 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 CHIEF OIL & GAS LLC Produced Fluid 3,903.72 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Unused Fracturing Fluid Waste 180.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 CHIEF OIL & GAS LLC Drill Cuttings 783.31 Tons LANDFILL 301358
2017 CHIEF OIL & GAS LLC Produced Fluid 60.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 CHIEF OIL & GAS LLC Produced Fluid 3,560.40 Bbl REUSE (AT WELL PAD)
2018 CHIEF OIL & GAS LLC Produced Fluid 180.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 CHIEF OIL & GAS LLC Produced Fluid 1,042.95 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2594931 Primary Facility 2017-05-16 Routine/Complete Inspection No Violations Noted
2610376 Primary Facility 2017-07-05 Routine/Complete Inspection No Violations Noted Drilling of the 3H well will be complete tonight. The drill of the 2H will begin shortly thereafter. All substances within secondary containment. No leaks or spills detected. No violations. Precision Rig 569 on site.
2649786 Primary Facility 2017-10-18 Incident- Response to Accident or Event No Violations Noted I arrived at the site in response to a spill notification received Tuesday 10/17 at 16:00 hrs. Chief reported that approximately 1 barrel of fracwater/brine with friction reducer was spilled to the pad when a valve cover failed on the missile. I met Justin Myers and Chris Marsh when I was on-site. We looked at the area where the spill had occurred, and they informed me that Kellon Balum of Chief arrived soon after the spill and stopped the frac. They observed fluid coming out from under the liner, so Kellon had the equipment removed from the area, the containment pulled back, and immediately began removing the affected soil. Chris estimated that 2.5-3 cubic yards of soil had been removed, and pointed out the pile of soil on containment. Kellon assisted the excavation by screening the soil for TDS and had the excavation continue until the soil reached background levels (100-200 ppm). Once he determined that the release had been removed, he noted several holes in the liner that had been pulled back. Th
2660021 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted I met Floyd Roberts of Chief when I arrived. Workover rig on location to drill out plugs. Some small puddles were present in the area of the spill reported on 10/17; conductivity of these puddles was low (from .098 to .9 mS/cm). Some of the foam berms had been removed in antraffic area on the containment; although I didn't note any chemicals or waste in this area, I recommended to Floyd that he assess whether or not the berms should be put back in place.
2676433 Primary Facility 2018-01-02 Incident- Response to Accident or Event Pending Well is shut in due to a fire in one of the GPU units on 12/29/2017.

The GPU for the 2H and 3H wells were removed from the well pad as well as containment, to allow access to further investigate the fire.

All wells on the pad were temp shut in at time of inspection.

All annulus vents are vented to polly tank on location.

For data sources see[8]