37-015-21566

Well Details

Well ID: 37-015-21566
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Windham Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 149562
Farm/Lease Name: WHEATON 05 223 01 W 1H
License Status:
Spud Date:
Permit Date: 2011-03-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.964997
Longitude: -76.279994

For data sources see[1][2][3]

Well History

Date Event
2011-03-10 New Permit Application
2011-03-29 Performed Spud Operation
2012-03-20 Perforation
2012-12-05 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-03-20 2012-03-20 4,896 2,996,078

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FEAC-20 Trican Well Service Iron Control Citric acid 77-92-9 30.00 0.00009000
Acetic acid 64-19-7 50.00 0.00016000
BIOCLEAR 5000 Trican Well Service Biocide Polyethylene glycol 25322-68-3 70.00 0.02
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 10.00 0.00338000
GFR-1D Trican Well Service Friction Reducer Anionic Water Soluble Polymer 100.00 0.01
AI-7NR Trican Well Service Acid Inhibitor Propargyl alcohol 107-19-7 1.00 0.00
FRAC WATER Talisman Energy Frac Water Water 7732-18-5 100.00 99.93
GFR-1 Trican Well Service Friction Reducer NON-HAZARDOUS 100.00 0.03
FRAC SAND Trican Well Service Frac Proppant Quartz 14808-60-7 100.00 17.30
Hydrochloric Acid 3.5 Trican Well Service Acid Spearhead Water 7732-18-5 96.50 0.06
Hydrochloric acid 7647-01-0 3.50 0.00233000
LSI-21 Trican Well Service Scale Inhibitor NON-HAZARDOUS 100.00 0.05

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2012 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2013 REPSOL OIL & GAS USA LLC 219,563.70 111 0.00 0 0.00 0
2014 REPSOL OIL & GAS USA LLC 355,129.00 359 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 251,934.80 351 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 220,107.30 366 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 188,483.60 365 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 164,143.80 364 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 167,036.50 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 REPSOL OIL & GAS USA LLC Drill Cuttings 122.00 Tons LANDFILL NY31346244
2011 REPSOL OIL & GAS USA LLC Drill Cuttings 30.00 Tons LANDFILL NY # 02S17
2011 REPSOL OIL & GAS USA LLC Drill Cuttings 102.00 Tons LANDFILL 8-0728-0004/013
2011 REPSOL OIL & GAS USA LLC Drilling Fluid Waste 194.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 7,124.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 REPSOL OIL & GAS USA LLC Produced Fluid 920.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 REPSOL OIL & GAS USA LLC Produced Fluid 524.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 REPSOL OIL & GAS USA LLC Produced Fluid 1,339.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 REPSOL OIL & GAS USA LLC Produced Fluid 1,112.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 REPSOL OIL & GAS USA LLC Produced Fluid 475.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 REPSOL OIL & GAS USA LLC Produced Fluid 3,229.93 Bbl REUSE OTHER THAN ROAD SPREADING
2014 REPSOL OIL & GAS USA LLC Produced Fluid 632.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 REPSOL OIL & GAS USA LLC Produced Fluid 1,593.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 REPSOL OIL & GAS USA LLC Produced Fluid 1,043.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 REPSOL OIL & GAS USA LLC Produced Fluid 475.00 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Produced Fluid 410.00 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 REPSOL OIL & GAS USA LLC Produced Fluid 200.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1960141 Primary Facility 2011-03-24 Routine/Complete Inspection No Violations Noted
2013386 Primary Facility 2011-10-24 Routine/Complete Inspection Pending No Well tag. Cellar filled with water. No visible bubbling. No gauges on annuli.
2156099 Primary Facility 2013-04-11 Routine/Complete Inspection No Violations Noted
2592052 Primary Facility 2017-05-02 Routine/Complete Inspection No Violations Noted On May 2, 2017, at 1130 hrs., the Department conducted a routine inspection at the Respol Oil and Gas Wheaton W 05-223 well site in Windham Township, Bradford County. The Department was represented by Andrew Hobbins, Water Quality Specialist. Nobody was present for Repsol. While on site, Rich Herbstrit, Oil and Gas Inspector, arrived to conduct his own inspection.

The E&S plan, site sign, and weekly inspection logs were on site and available for review. The slopes of the pad were well vegetated. No erosion issues were observed.

One well was in production during the inspection. The well was labeled and no bubbling was observed in the well cellar. One production tank and one GPU was observed on site. Both the production tank and the GPU were in secondary containment. The containment structures were in good condition. Water within the containment structures was low in specific conductivity. There was no staining observed on the well pad surface. All puddles on the pad were low in specific conductivity.

The w

2779027 Primary Facility 2018-09-13 Site Restoration No Violations Noted The DEP conducted a RESTORATION inspection of the Repsol Wheaton (05-223) W Pad in Windham Twp, Bradford County on 9/13/2018 at 1240 hours. The inspection was conducted in response to a Notice of Termination received by the DEP. The weather was 73 degrees, cloudy, and 90% humidity.

The site has one producing well and three plugged wells onsite with one production tank. The site appears to have all planned PCSM practices in place and the site appears to be stabilized. No erosional issues were noted and no temporary E&S BMPs were observed. A post-drilling well site restoration report has been accepted by the DEP.

This Notice of Termination is recommended for approval. No violations noted at this time.

I departed the site at 1310.

For data sources see[8]