If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-21129 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.972308,"lon":-76.716253,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Bradford | |
Municipality: Ridgebury Township | |
Operator Name: EOG RESOURCES INC | |
Well Pad ID: 146979 | |
Farm/Lease Name: STURDEVANT 1H | |
License Status: INACTIVE | |
Spud Date: | |
Permit Date: 2010-10-20 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.972308 | |
Longitude: -76.716253 |
Date | Event |
---|---|
2010-10-20 | New Permit Application |
2010-11-20 | Performed Spud Operation |
2011-07-12 | Perforation |
2012-11-09 | DEVIATED |
2019-02-21 | Inactive Well Request Granted |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-08-04 | 2011-08-04 | 4,198 | 30,912 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid | Basic Chemical Solutions | Acid | Hydrochloric acid | 7647-01-0 | 7.50 | 1.24 | |
Interstate ICA-2 | Iron Control | Ethylene glycol | 107-21-1 | 60.00 | 0.00443000 | |||
Water | 7732-18-5 | 60.00 | 0.00443000 | |||||
D-Gluconic acid | 526-95-4 | 10.00 | 0.00074000 | |||||
BioClear 1000 | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 100.00 | 0.00232000 | |||
Sand | EOG Resources | Proppant | Quartz | 14808-60-7 | 100.00 | 2.10 | ||
Water | EOG Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100.00 | 81.17 | ||
SCALE CLEAR SI 112 | Weatherford | Scale Inhibitor | Ethylene glycol | 107-21-1 | 40.00 | 0.00876000 | ||
Plexslick 921E | Chemplex | Friction Reducer for Water | ||||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | |||||
ENVIROHIB 2001 | Corrosion Inhibitor | 2-Butoxyethanol | 111-76-2 | 40.00 | 0.00307000 | |||
Ethylene glycol | 107-21-1 | 60.00 | 0.00460000 | |||||
Formic acid | 64-18-6 | 40.00 | 0.00307000 | |||||
Cinnamaldehyde (3-phenyl-2-propenal) | 104-55-2 | 40.00 | 0.00307000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | EOG RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | EOG RESOURCES INC | Drill Cuttings | 871.47 Tons | LANDFILL | 31346244 |
2019 | EOG RESOURCES INC | Produced Fluid | 98.90 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EOG RESOURCES INC | Produced Fluid | 345.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | EOG RESOURCES INC | Produced Fluid | 25.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2007962 | Primary Facility | 2011-10-04 | Routine/Complete Inspection | No Violations Noted | |
2264319 | Primary Facility | 2014-04-01 | Site Restoration | No Violations Noted | Restored pad, approx. 91m perimeter. 1 well drilled, not in production. |
2637590 | Primary Facility | 2017-09-19 | Routine/Complete Inspection | No Violations Noted | Inspection to assess overall site conditions. The well sit is restored. No violations cited. |
2680857 | Primary Facility | 2018-01-10 | Routine/Complete Inspection | No Violations Noted | Well is shut in at time of inspection.
Well is on inactive status at time of inspection. All anulus vents are connected to one 1 1/4 inch vent vented to polly tank on location, tested for LEL & Methane at polly tank with an altair 5x multigas detector. Readings were 100% LEL and 82% Methane/Vol at time of inspection, was unable to specifically identify what annulus vent was venting due to all vents being vented to a single vent line. 2,000 PSI on the production tubing. |
2723648 | Primary Facility | 2018-04-26 | Routine/Partial Inspection | No Violations Noted | I took combustible gas readings from the 3 annulus vent barrels (photo) with an Altair 5x meter. The 1st 2 barrels gave 0% LEL & methane readings. The 3rd barrel gave a reading of 11% methane.
I did not take electrical conductivity readings, because I did not see any accessible standing water on site (there is some water in the black tote that holds the 3 blue barrels). |
2727448 | Primary Facility | 2018-05-08 | Routine/Complete Inspection | No Violations Noted | The three annulus vents have been separated into individual vents and are vented into plastic drums. Annular vents are not identifiable at time of inspection. |
2735253 | Primary Facility | 2018-05-21 | Routine/Complete Inspection | No Violations Noted | Reason for inspection is to meet with EOG to collect gas samples from each of the annulus vent and perform A 72 hour PBUT. On location with Caleb Woolever (PADEP), Clayton Schucker (Moody and associates), and Ed Sicora (EOG). PBUT valves closed at 13:18 pm. 2,220 psi production casing. |
2801736 | Primary Facility | 2018-11-13 | Routine/Complete Inspection | No Violations Noted | Cool/snowy at time of inspection.
All vents are vented to plastic 55 gallon drums on location. Performed headspace test around well head, Test results showed no Methane or LEL present. Methane/LEL % by volume from all three annulus vents are consistent with prior inspections at this well site. |
2828256 | Primary Facility | 2019-01-17 | Routine/Complete Inspection | No Violations Noted | Cool/windy at time of inspection.
All vents vented into plastic barrels onsite. |
For data sources see[8]