X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-20667

Well Details

Well ID: 37-015-20667
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Monroe Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 150567
Farm/Lease Name: KINGSLEY UNIT
License Status: Inactive
Spud Date:
Permit Date: 2010-03-11
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.625583
Longitude: -76.476583

For data sources see[1][2][3]

Well History

Date Event
2010-03-11 New Permit Application
2010-06-02 Performed Spud Operation
2010-08-10 NEWLY DRILLED
2010-09-10 Perforation
2010-09-10 Performed Stage 1 of Stimulation
2019-10-30 Inactive Well Request Granted

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2010-09-10 1 Sand 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CHIEF OIL & GAS LLC Drilling Fluid Waste 579.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0027057
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 435.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0027057
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 4,374.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011 CHIEF OIL & GAS LLC Drill Cuttings 1,307.46 Tons LANDFILL 301358
2012 CHIEF OIL & GAS LLC Drilling Fluid Waste 2,830.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2012 CHIEF OIL & GAS LLC Drill Cuttings 121.55 Tons LANDFILL 100955
2013 CHIEF OIL & GAS LLC Produced Fluid 279.50 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1890965 Primary Facility 2010-06-11 Drilling/Alteration No Violations Noted
1895752 Primary Facility 2010-06-25 Routine/Complete Inspection Violation(s) Noted
1900932 Primary Facility 2010-07-21 Routine/Partial Inspection Outstanding Violations - No Viols Req'd
1907040 Primary Facility 2010-08-16 Routine/Complete Inspection No Violations Noted checked cellar for gas leak. found only very little bubble less than normal
2094344 Primary Facility 2012-07-25 Routine/Complete Inspection No Violations Noted No water in cellar. 2annular vents go to 550 gal poly tank. MSA Altair 5X gas meter reading of comb = XXX and 30% methane in tank. Sign at entrance to pad has Burlington Twp and sign on well is wrong - is for A 2H(37-015-21749). Talked to Rich Adams(Chief rep.) on 8/24/2012 to get corrected.
2486006 Primary Facility 2016-05-17 Site Restoration No Violations Noted
2520272 Primary Facility 2016-09-13 Routine/Complete Inspection No Violations Noted
2567315 Primary Facility 2017-02-21 Routine/Complete Inspection No Violations Noted
2602359 Primary Facility 2017-06-08 Routine/Complete Inspection No Violations Noted Three wells in production status. One well not in production. Three water separators within containment. No leaks detected from production equipment. Petroleum substance within 2H Well celler. No violations cited at this time.
2717027 Primary Facility 2018-03-15 Routine/Complete Inspection No Violations Noted Arrived at 11:00 with Jon Hafer to conduct inspection for regulatory inactive well status extension request. This is the second extension request for this well. The 9-5/8" x 5-1/2" annulus was open and vented to a 550- gallon polytank where no methane was detected. The 20" x 13-3/8" and 13-3/8" x 9-5/8" annuli could not be observed because the cellar was filled with gravel. Requested a follow- up inspection with the cellar vacced out to observe these annuli. The three other wells onsite were in production. No violations were observed at the time of this inspection.
2718435 Primary Facility 2018-04-10 Follow-up Inspection No Violations Noted Arrived at 09:00. Weather: cold, with snow on the ground. This was a follow up on a regulatory inactive well status extension request. This is the second extension request for this well. Jon Hafer and a Mountain Energy crew were onsite removing gravel from the well cellar to expose the 20" x 13-3/8" and 13-3/8" x 9-5/8" annuli for observation (photo 1). Annuli were filled with cement. No bubbling was observed when annuli were covered by a few inches of water. During the inspection, scorch marks were observed on one of the GPUs (photos 3 & 4). Peg Farrell responded to a query about the scorching as follows: "In February 2016, a fire was discovered to have occurred at a Kingsley A GPU, and to have been immediately extinguished upon the automatic shut-off mechanism functioning as designed. The other wells on the pad remained in operation. Since it was discovered after resolution occurred and there was only minor damage, no emergency services were engaged. No fluids were released, so there was no spill to report

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1895752 590644 06/25/2010 2010-06-25 78.56LINER - Improperly lined pit Administrative 78.56(a) - failure to contain a pollutional substance
1895752 590645 06/25/2010 2010-06-25 301UNPMTIW - Industrial waste was discharged without permit. Environmental Health & Safety 6018.301 - cuttings were dusted

For data sources see[8]

References