If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-31150 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.825872,"lon":-79.690606,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: West Franklin Township | |
Operator Name: PENNENERGY RESOURCES LLC | |
Well Pad ID: 145827 | |
Farm/Lease Name: PAD W16 | |
License Status: Active | |
Spud Date: 2013-10-07 | |
Permit Date: 2013-07-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.825872 | |
Longitude: -79.690606 |
Date | Event |
---|---|
2013-07-19 | New Permit Application |
2013-10-07 | Performed Spud Operation |
2013-10-29 | Drilling Completion |
2014-08-06 | Perforation |
2014-08-20 | Perforation |
2014-08-20 | Performed Stage 1 of Stimulation |
2014-08-20 | Performed Stage 2 of Stimulation |
2014-08-21 | Perforation |
2014-08-21 | Performed Stage 3 of Stimulation |
2014-08-21 | Performed Stage 4 of Stimulation |
2014-08-21 | Performed Stage 5 of Stimulation |
2014-08-21 | Performed Stage 6 of Stimulation |
2014-08-21 | Performed Stage 7 of Stimulation |
2014-08-22 | Perforation |
2014-08-22 | Performed Stage 8 of Stimulation |
2014-08-22 | Performed Stage 9 of Stimulation |
2014-09-01 | Perforation |
2014-09-01 | Performed Stage 10 of Stimulation |
2014-09-01 | Performed Stage 11 of Stimulation |
2014-09-01 | Performed Stage 12 of Stimulation |
2014-09-02 | Perforation |
2014-09-02 | Performed Stage 13 of Stimulation |
2014-09-02 | Performed Stage 14 of Stimulation |
2014-09-02 | Performed Stage 15 of Stimulation |
2014-09-02 | Performed Stage 16 of Stimulation |
2014-09-02 | Performed Stage 17 of Stimulation |
2014-09-02 | Performed Stage 18 of Stimulation |
2014-09-02 | Performed Stage 19 of Stimulation |
2014-09-02 | Performed Stage 20 of Stimulation |
2014-09-03 | Perforation |
2014-09-03 | Performed Stage 21 of Stimulation |
2014-09-03 | Performed Stage 22 of Stimulation |
2014-09-03 | Performed Stage 23 of Stimulation |
2014-09-09 | New Permit Application |
2017-03-29 | Deviated |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2014-08-25 | 2014-08-30 | 6,223 | 7,864,000 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | PennEnergy Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 86.2144 | 65,815,400.0 |
Scale Hib A | Nalco | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00337494 | 2576.4 | |
Sand (Proppant) | Sargent | Proppant | Silica | 14808-60-7 | 99.9 | 11.1324 | 8,498,410.0 | |
Unislik ST50 | CESI | Friction Reducer | Petroleum Distillates, Hydrotreated Light | 64742-47-8 | 30 | 0.026739 | 20412.3 | |
I-7L | Weatherford | Iron Control | Ethylene Glycol | 107-21-1 | 20 | 0.00215254 | 1643.23 | |
Triethanolamine Hydroxyacetate | 68299-02-5 | 20 | 0.00215254 | 1643.23 | ||||
Glycolic Acid | 79-14-1 | 2.5 | 0.000269067 | 205.404 | ||||
Unihib G | GeoSafe | Acid Corrosion Inhibitor | Acetophenone | 98-86-2 | 1 | 0.00000813 | 6.209 | |
Formaldehyde | 50-00-0 | 1 | 0.00000813 | 6.209 | ||||
Glycol Ether | 112-34-5 | 60 | 0.000487981 | 372.521 | ||||
Methanol | 67-56-1 | 5 | 0.00004067 | 31.043 | ||||
Ethoxylated Alcohol | 68002-97-1 | 35 | 0.000284655 | 217.304 | ||||
Thiourea | 62-56-6 | 1 | 0.00000813 | 6.209 | ||||
LEB 10X | Weatherford | Gel Breaker | Ethylene Glycol | 107-21-1 | 40 | 0.00001494 | 11.403 | |
Hydrochloric Acid (7.5%) | Axiall | Acidizing | Hydrogen Chloride | 7647-01-0 | 40 | 0.993702 | 758585 | |
EC6116A | Nalco | Biocide | Polyethylene Glycol | 25322-68-3 | 60 | 0.0265858 | 20295.4 | |
Dibromoacetonitrile | 3252-43-5 | 5 | 0.00221548 | 1691.28 | ||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30 | 0.0132929 | 10147.7 | ||||
WGA-3 | PfP Technology | Water Viscosifier | Guar Gum | 9000-30-0 | 100 | 0.00144094 | 1100 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2014-08-20 | 1 | SAND | 7,468,146 | 7,211 | 5,986 |
2014-08-20 | 2 | SAND | 7,468,146 | 7,847 | 5,868 |
2014-08-21 | 3 | SAND | 7,468,146 | 7,581 | 5,669 |
2014-08-21 | 4 | SAND | 7,468,146 | 8,025 | 6,155 |
2014-08-21 | 5 | SAND | 7,468,146 | 7,901 | 5,970 |
2014-08-21 | 6 | SAND | 7,468,146 | 7,738 | 6,730 |
2014-08-21 | 7 | SAND | 7,468,146 | 7,677 | 6,555 |
2014-08-22 | 8 | SAND | 7,468,146 | 7,682 | 7,942 |
2014-08-22 | 9 | SAND | 7,468,146 | 7,354 | 7,050 |
2014-09-01 | 10 | SAND | 7,468,146 | 7,469 | 7,221 |
2014-09-01 | 11 | SAND | 7,468,146 | 7,449 | 7,224 |
2014-09-01 | 12 | SAND | 7,468,146 | 7,389 | 7,680 |
2014-09-02 | 13 | SAND | 7,468,146 | 7,195 | 7,763 |
2014-09-02 | 14 | SAND | 7,468,146 | 7,073 | 7,598 |
2014-09-02 | 15 | SAND | 7,468,146 | 6,815 | 7,013 |
2014-09-02 | 16 | SAND | 7,468,146 | 7,214 | 5,900 |
2014-09-02 | 17 | SAND | 7,468,146 | 7,147 | 6,606 |
2014-09-02 | 18 | SAND | 7,468,146 | 7,222 | 6,380 |
2014-09-02 | 19 | SAND | 7,468,146 | 6,971 | 7,085 |
2014-09-02 | 20 | SAND | 7,468,146 | 6,936 | 8,914 |
2014-09-03 | 21 | SAND | 7,468,146 | 7,185 | 7,171 |
2014-09-03 | 22 | SAND | 7,468,146 | 7,085 | 8,919 |
2014-09-03 | 23 | SAND | 7,468,146 | 6,815 | 6,360 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | PENNENERGY RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | PENNENERGY RESOURCES LLC | 277,055.00 | 102 | 0.00 | 0 | 0.00 | 0 |
2015 | PENNENERGY RESOURCES LLC | 845,517.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2016 | PENNENERGY RESOURCES LLC | 696,127.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | PENNENERGY RESOURCES LLC | 561,251.00 | 319 | 0.00 | 0 | 0.00 | 0 |
2018 | PENNENERGY RESOURCES LLC | 520,261.00 | 353 | 0.00 | 0 | 0.00 | 0 |
2019 | PENNENERGY RESOURCES LLC | 419,295.00 | 357 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 3,120.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2013 | PENNENERGY RESOURCES LLC | Drill Cuttings | 667.00 Tons | LANDFILL | CID # 28726 |
2014 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 1,630.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2014 | PENNENERGY RESOURCES LLC | General O&G waste not covered by other waste types | 9.03 Tons | LANDFILL | CID # 28726 |
2014 | PENNENERGY RESOURCES LLC | Fracturing Fluid Waste | 84.14 Tons | LANDFILL | CID # 28726 |
2014 | PENNENERGY RESOURCES LLC | Drill Cuttings | 399.60 Tons | LANDFILL | CID # 28726 |
2014 | PENNENERGY RESOURCES LLC | Drilling Fluid Waste | 1,630.00 Bbl | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2015 | PENNENERGY RESOURCES LLC | Produced Fluid | 282.19 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid | 1,254.81 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid | 95.02 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid | 536.21 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2016 | PENNENERGY RESOURCES LLC | Waste Water Treatment Sludge | 2.70 Tons | LANDFILL | UT2300249 |
2016 | PENNENERGY RESOURCES LLC | Produced Fluid | 3,147.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | PENNENERGY RESOURCES LLC | 1,472.55 Bbl | REUSE (AT WELL PAD) | ||
2017 | PENNENERGY RESOURCES LLC | Produced Fluid | 22.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | PENNENERGY RESOURCES LLC | Produced Fluid | 1,832.62 Bbl | REUSE (AT WELL PAD) | |
2017 | PENNENERGY RESOURCES LLC | 22.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 | |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 2,038.03 Bbl | REUSE (AT WELL PAD) | |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 113.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2018 | PENNENERGY RESOURCES LLC | Produced Fluid | 112.00 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 106.08 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2019 | PENNENERGY RESOURCES LLC | Waste Water Treatment Sludge | 2.45 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 224.74 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 51.36 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 1,416.83 Bbl | REUSE (AT WELL PAD) | |
2019 | PENNENERGY RESOURCES LLC | Produced Fluid | 436.60 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2212633 | Primary Facility | 2013-10-10 | Drilling/Alteration | No Violations Noted | Spud in 10-08-13. Inspection conducted w/OGI J. Branan. |
2217757 | Primary Facility | 2013-10-24 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence tophole drilling. |
2217766 | Primary Facility | 2013-10-30 | Drilling/Alteration | No Violations Noted | Highlands rig#8 drilling at 737’ at time of inspection. Closed loop system being utilized. |
2220463 | Primary Facility | 2013-11-06 | Drilling/Alteration | No Violations Noted | Highlands rig#8 rigged down in preparation for move at time of inspection. Inspection conducted w/OGI J. Branan. |
2223663 | Primary Facility | 2013-11-20 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. The drill rig that had been onsite was in the process of being rigged down and moved off-site. Drilling equipment was located on plastic containement. Site had been constructed as outlined in the E&S plan within the ESCGP-2. There was no observed accelerated erosion or sedimentation in relation to the site or access road. In addition all fill and cut slopes had been temporarily stabilized with vegetation. |
2238688 | Primary Facility | 2014-01-23 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. Earthmoving activities were ongoing to further stabilize a section on the edge of the pad so as to enable equipment to be parked in that area. Site had been constructed as outlined in the E&S plan within the ESCGP-2. There was no observed accelerated erosion or sedimentation in relation to the site or access road. In addition all fill and cut slopes had been temporarily stabilized with vegetation. |
2261375 | Primary Facility | 2014-04-08 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. Well was not equipped for production at the ttime of the inspection. Site had been constructed as outlined in the E&S plan within the ESCGP-2. There was no observed accelerated erosion or sedimentation in relation to the site or access road. In addition all fill and cut slopes had been temporarily stabilized with vegetation. Unlined frac impoundment located onsite. Secondary containment liner located on the drill pad. It was noted that earthmoving activities were ongoing adjacent to the site for the associated pipeline project and that a portion of the well pad was being utlized for these purposes. |
2275847 | Primary Facility | 2014-05-21 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence lateral drilling. Inspection conducted w/OGI D. Catalano. |
2291262 | Primary Facility | 2014-07-29 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well production equipment had been installed onsite. Brine tanks located onsite and they appeared to be in sound condition. Freshwater impoundment located onsite and it was holding minimal fluids. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2308421 | Primary Facility | 2014-09-30 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite inside secondary containment and they appeared to be in sound condition. Freshwater impoundment located onsite. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2325318 | Primary Facility | 2014-12-02 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite inside secondary containment and they appeared to be in sound condition. Freshwater impoundment located onsite. Constructed AST observed onsite. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2364087 | Primary Facility | 2015-04-22 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tank located onsite and it appeared to be in sound condition. All site and access road erosion controls had been properly maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. Impoundment located onsite and it had more than two feet of lined freeboard. In addition there was a large AST located on the well-pad. |
2444853 | Primary Facility | 2016-01-29 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tank located onsite and it appeared to be in sound condition. All site and access road erosion controls had been properly maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. Impoundment located onsite and it had more than two feet of lined freeboard. |
2470361 | Primary Facility | 2016-03-31 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-production set-equipment-tank battery and dike look ok. |
2538305 | Primary Facility | 2016-11-21 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tank located onsite and it appeared to be in sound condition. All site and access road erosion controls had been properly maintained. There was no observed accelerated erosion or sedimentation observed in relation to the site or access road. Impoundment located onsite and it had more than two feet of lined freeboard. |
2606601 | Primary Facility | 2017-06-22 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion in relation to the site or access road. Well development impoundment located onsite and it contained fluids. |
2612559 | Primary Facility | 2017-07-06 | Routine/Complete Inspection | No Violations Noted | Well tagged-on. Well head casing-production set equipment-tank battery-dike containment look ok. |
2701777 | Primary Facility | 2018-03-06 | Routine/Complete Inspection | No Violations Noted | At time of inspection, well 1H is drilled and appears equipped for production. Well 2H is also drilled and appears equipped for production. |
2793321 | Primary Facility | 2018-10-23 | Routine/Complete Inspection | No Violations Noted | Well appears equipped for production. Well head surrounded by cement barriers. Two brine tanks on site. |
2821528 | Primary Facility | 2019-01-03 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The well head casing, piping, production set equipment, containment dike and tank battery look ok. |
For data sources see[9]