37-005-31122

Well Details

Well ID: 37-005-31122
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Boggs Township
Operator Name: SNYDER BROS INC
Well Pad ID: 147036
Farm/Lease Name: W H KUHNS HEIRS 6M-143
License Status:
Spud Date:
Permit Date: 2013-01-17
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.913756
Longitude: -79.368794

For data sources see[1][2][3]

Well History

Date Event
2013-01-17 New Permit Application
2013-04-15 Performed Spud Operation
2013-04-25 Drilling Completion
2013-05-20 Perforation
2014-04-10 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-05-21 2013-05-21 6,675 156,900 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 HCl Acid (12.5%-18.0%) Nabors Completion and Production Services Bulk Acid Hydrogen Chloride 7647-01-0 18 0.028856 0
ClayTreat LT Nabors Completion and Production Services Clay Control Additives ammonium, (2-Hydroxyethyl)trimethyl-, chloride 67-48-1 80 0.00053 0
Demineralized Water 7732-18-5 50 0.000331 0
HCL Acid (0%-7.5%) Nabors Completion and Production Services Bulk Acid Hydrogen Chloride 7647-01-0 7.5 0.011826 0
Water 7732-18-5 92.5 0.145857 0
ICP-1000 Nabors Completion and Production Services Iron Control Additives Propylene glycol 57-55-6 50 0.005336 0
Anionic Copolymer Proprietary 50 0.005336 0
Nitrogen per MSCF Nabors Completion and Production Services Nitrogen Materials Nitrogen 7727-37-9 100 33.2911 0
PA Specific 40/70 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Titanium Oxide 13463-67-7 0.1 0.011844 0
Iron Oxide 1309-37-1 0.1 0.011844 0
Crystalline Silica, quartz 14808-60-7 99.9 11.8324 0
Aluminum Oxide 1344-28-1 1.1 0.130287 0
Other Ingredients Nabors Completion and Production Services Other Ingredients Propylene glycol 57-55-6 15 0.014474 0
Ammonium salts Proprietary 100 0.027811 0
Ethoxylated alcohols (C10-C16) 68002-97-1 15 0.014474 0
Proprietary Proprietary 1 0.001391 0
Phosphoric Acid 7664-38-2 100 0.001391 0
Monoethanolamine Proprietary 100 0.001391 0
Water 7732-18-5 80 0.004459 0
Proprietary Proprietary 2 0.00193 0
Water 7732-18-5 40 0.038597 0
Proprietary Proprietary 15 0.000769 0
Proprietary Proprietary 50 0.002563 0
Ethoxylated oleylamine 26635-93-8 5 0.004825 0
Polymer Proprietary 10 0.013906 0
Water 7732-18-5 60 0.003075 0
Water 7732-18-5 87.5 0.140271 0
Water 7732-18-5 48 0.000435 0
Polymer Proprietary 1 0.001391 0
2-Butoxyethanol 111-76-2 13 0.000118 0
Anionic Polyacrylamide 910644-97-2 40 0.038597 0
Solvent Proprietary 1 0.001391 0
Water 7732-18-5 50 0.069528 0
Proprietary Proprietary 100 0.139057 0
Dioxane 123-91-1 1 0.00000900 0
Proprietary Proprietary 100 0.000616 0
Alkyl Phosphate Ether Proprietary 1 0.001391 0
Super 100 NE Nabors Completion and Production Services Surfactants & Foamers Methanol 67-56-1 15 0.020859 0
N-Cocoamidopropyl-N,N-dimethyl-N-2-hydroxypropylsulfobetaine
68139-30-0 15 0.020859 0
Glycol Ether 111-76-2 5 0.006953 0
Isopropyl Alcohol 67-63-0 40 0.055623 0
KR-153SL Nabors Completion and Production Services Biocides 2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.001115 0
Polyethlyene-Glycol 25322-68-3 50 0.002787 0
Acid Inhibitor 2 (AI-2) Nabors Completion and Production Services Acid Corrosion Inhibitors Isopropyl Alcohol 67-63-0 40 0.000363 0
Propargyl Alcohol 107-19-7 40 0.000363 0
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 10 0.00009100 0
Glycol Ethers 111-46-6 40 0.000363 0
Ethoxylated Nonylphenol 68412-54-4 13 0.000118 0
PA Specific 30/50 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Crystalline Silica, quartz 14808-60-7 99.9 6.37158 0
Titanium Oxide 13463-67-7 0.1 0.006378 0
Iron Oxide 1309-37-1 0.1 0.006378 0
Aluminum Oxide 1344-28-1 1.1 0.070158 0
Water SNYDER BROTHERS INC Water Water 7732-18-5 100 47.9096 0
WFR-3B Nabors Completion and Production Services Friction Reducer Hydrotreated light distillates, non-aromatic, BTEX free 64742-47-8 30 0.028948 0
Super MAX II Nabors Completion and Production Services Surfactants & Foamers Isopropyl Alcohol 67-63-0 5 0.00003100 0
1-Decanol 112-30-1 5 0.00003100 0
Propylene Glycol 57-55-6 30 0.000185 0
Orange Terpenes 8028-48-6 5 0.00003100 0
Propylene Glycol n-butyl ether 5131-66-8 10 0.00006200 0
Oxirane, methyl-, polymer with
oxirane, mono(2-ethylhexyl) ether
64366-70-7 13 0.00008000 0
Water 7732-18-5 50 0.000308 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SNYDER BROS INC 33,943.00 188 0.00 0 0.00 0
2014 SNYDER BROS INC 30,544.00 364 0.00 0 0.00 0
2015 SNYDER BROS INC 19,540.00 365 0.00 0 0.00 0
2016 SNYDER BROS INC 15,438.00 344 0.00 0 0.00 0
2017 SNYDER BROS INC 13,256.00 365 0.00 0 0.00 0
2018 SNYDER BROS INC 12,431.00 363 0.00 0 0.00 0
2019 SNYDER BROS INC 11,127.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SNYDER BROS INC Fracing Fluid Waste 1,005.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SNYDER BROS INC Drill Cuttings 117.00 Tons ON SITE ENCAPSULATION
2013 SNYDER BROS INC Fracing Fluid Waste 1,410.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW006
2013 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2013 SNYDER BROS INC Produced Fluid 135.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW006
2013 SNYDER BROS INC Fracing Fluid Waste 1,095.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 SNYDER BROS INC Produced Fluid 180.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 SNYDER BROS INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015 SNYDER BROS INC Produced Fluid 30.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2017 SNYDER BROS INC Produced Fluid 49.00 Bbl INJECTION DISPOSAL WELL 34-155-23196

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2152085 Primary Facility 2013-03-29 Routine/Complete Inspection No Violations Noted Site construction had been completed at the time of the inspection. The minimal erosion controls neccesary for the site had been implemented as outlined in the E&S plan. It was noted that the drill pit was constructed above grade due to soil conditions.
2159289 Primary Facility 2013-04-17 Drilling/Alteration No Violations Noted cementing mine string
2162839 Primary Facility 2013-04-29 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well did not appear to have been stimulated. The minimal erosion controls neccesary for the site had been implemented as outlined in the E&S plan and there was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted that the drill pit was constructed above grade due to soil conditions. Drill pit contained cuttings and fluids. Drill pit had more than the required two feet of lined freeboard.
2164912 Primary Facility 2013-04-23 Drilling/Alteration No Violations Noted @ 3179'
2196956 Primary Facility 2013-08-13 Routine/Complete Inspection No Violations Noted Drilling and stimulation appeared to have been completed. Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Above grade drill pit located onsite and it contained minimal fluids. There was no accelerated erosion or sedimentation in relation to the site.
2230547 Primary Facility 2013-12-17 Site Restoration No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no accelerated erosion or sedimentation in relation to the site. Site had been regraded, seeded, mulched and the vegetative cover had attained the 70% uniform coverage criteria.
2347037 Primary Facility 2015-02-25 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. The well was located in what had been a cultivated corn field. Brine tanks located onsite and they appeared to be in sound condition.
2555097 Primary Facility 2017-01-25 Routine/Complete Inspection No Violations Noted Well tagged-in production. Annulus was open. Well head casing-production set equipment- 2 grounded 100 bbl fiberglass tanks looked ok.
2678003 Primary Facility 2018-01-04 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The well head casing, production set equipment and 2 grounded 100 bbl fiberglass tanks look ok.
2681357 Primary Facility 2018-01-11 Routine/Complete Inspection No Violations Noted At time of inspection, well drilled and appears equipped for production.
2828226 Primary Facility 2019-01-17 Routine/Complete Inspection No Violations Noted On 1/17/19 at 0834 hrs., I conducted a routine inspection of Snyder Brothers, Inc.'s W H Kuhns Hers 6M-143 well (API 005-31122) in Boggs Twp., Armstrong Co. The well pad is restored and permanently stabilized. The well is equipped for production. A site ID sign is present at the entrance to the well pad. A well tag is affixed to the well head. An Emergency Response Plan is located onsite. There are no violations noted for this inspection.
2836932 Primary Facility 2019-02-05 Routine/Partial Inspection No Violations Noted At the time of inspection, well was equipped for production. The integrity appeared to be in good condition, with no leaks being observed. Well was painted and no corrosion was noticed. Area was under water near the wellhead and there were no bubbles seen. The well was properly labeled and the Emergency Response sign was posted at the site entrance. A Barton chart was last changed on 1/28. There were 2 separators and a line heater hooked up as well as 2 tanks being used. There was a conventional well located near the well's production facilities.

For data sources see[8]

References