{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.698728,"lon":-79.481867,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Burrell Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 148413 | |
Farm/Lease Name: GIBSON 590947 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-09-13 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.698728 | |
Longitude: -79.481867 |
Date | Event |
---|---|
2012-09-13 | New Permit Application |
2012-11-17 | Performed Spud Operation |
2013-03-18 | Drilling Completion |
2013-04-17 | Perforation |
2014-04-15 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-04-17 | 2013-04-26 | 6,995 | 10,384,400 | 310,359 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | LP-65 | Halliburton | Scale Inhibitor | Ammonium Chloride | 12125-02-9 | 10 | 0.0025 | 0 |
SP Breaker | Halliburton | Oxidizing Breaker | Sodium Persulfate | 7775-27-1 | 100 | 0.0015 | 0 | |
Sand | Halliburton | Proppant | Crystalline Silica | 14808-60-7 | 100 | 6.8412 | 0 | |
BE-9 | Halliburton | Biocide | Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.0008 | 0 | |
Water | Halliburton | Carrier | Water | 7732-18-5 | 100 | 92.9821 | 0 | |
BA-40L | Halliburton | Buffer | Potassium carbonate | 584-08-7 | 60 | 0.0024 | 0 | |
28% HCl | Halliburton | Dissolves cement & minerals in perforations | Propargyl Alcohol | 107-19-7 | 10 | 0.014 | 0 | |
Methanol | 67-56-1 | 60 | 0.0842 | 0 | ||||
Hydrochloric Acid | 7647-01-0 | 28 | 0.0393 | 0 | ||||
WG-36 | Halliburton | Gelling Agent | Guar Gum | 9000-30-0 | 100 | 0.0032 | 0 | |
FR-66 | Halliburton | Friction Reducer | Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0287 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 1,229,816.00 | 204 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 1,146,860.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 849,682.00 | 346 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 682,423.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 564,710.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 487,299.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 434,475.00 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | EQT PROD CO | Produced Fluid | 21,495.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21473 |
2013 | EQT PROD CO | Fracturing Fluid Waste | 307.00 Tons | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 877.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2013 | EQT PROD CO | Produced Fluid | 200.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2013 | EQT PROD CO | Drilling Fluid Waste | 80.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 1,585.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2013 | EQT PROD CO | Produced Fluid | 131.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24067 |
2013 | EQT PROD CO | Fracing Fluid Waste | 13,211.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 280.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2013 | EQT PROD CO | Produced Fluid | 113.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2013 | EQT PROD CO | Produced Fluid | 1,433.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24137 |
2013 | EQT PROD CO | Produced Fluid | 768.00 Bbl | INJECTION DISPOSAL WELL | 34-099-20974 |
2014 | EQT PROD CO | Produced Fluid | 10,463.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2014 | EQT PROD CO | Fracturing Fluid Waste | 1.42 Tons | LANDFILL | 100434 |
2014 | EQT PROD CO | Produced Fluid | 1,069.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2014 | EQT PROD CO | Produced Fluid | 86.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2014 | EQT PROD CO | Fracing Fluid Waste | 100.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-007-23262 |
2015 | EQT PROD CO | Produced Fluid | 96.00 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2015 | EQT PROD CO | Produced Fluid | 73.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | EQT PROD CO | Produced Fluid | 100.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24076 |
2015 | EQT PROD CO | Produced Fluid | 298.00 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2015 | EQT PROD CO | Produced Fluid | 377.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2015 | EQT PROD CO | Produced Fluid | 178.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | EQT PROD CO | Produced Fluid | 5,131.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 3,513.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 561.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | EQT PROD CO | Produced Fluid | 1,040.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 727.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | EQT PROD CO | Produced Fluid | 1,391.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 47.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 1,739.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | 690.00 Bbl | REUSE (AT WELL PAD) | ||
2017 | EQT PROD CO | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 | |
2017 | EQT PROD CO | 1,391.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 | |
2017 | EQT PROD CO | Produced Fluid | 220.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 301.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 1,367.19 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | EQT PROD CO | Produced Fluid | 74.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | EQT PROD CO | Produced Fluid | 163.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid | 1,597.02 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 76.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 2,428.90 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2115449 | Primary Facility | 2012-11-13 | Routine/Complete Inspection | No Violations Noted | Site inspection performed to meet the pre-operational inspection requirement. All perimter controls had been properly implemented. Final rocking and grading was underway on the well pad and impoundment earthmoving activities were underway. There was no observed accelerated erosion or sedimentation in relation to the access road or site. |
2121794 | Primary Facility | 2012-11-29 | Drilling/Alteration | No Violations Noted | no equipment on site |
2121979 | Primary Facility | 2012-12-06 | Drilling/Alteration | No Violations Noted | drilling to intermediate CP |
2122137 | Primary Facility | 2012-12-10 | Routine/Complete Inspection | No Violations Noted | All access road and site erosion controls had been implemented as outlined in the E&S plan contained within the ESCGP. There was no observed accelerated erosion or sedimentation at the time of the inspection. Secondary containment was located underneath all necessary equipment. |
2123899 | Primary Facility | 2012-12-14 | Drilling/Alteration | No Violations Noted | drilled to 6170' |
2142492 | Primary Facility | 2013-02-22 | Routine/Complete Inspection | No Violations Noted | Site construction had been completed, drilling was not ongoing at the time of the inspection. All site and access road erosion controls had been implemented as outlined in the E&S plan within the ESCGP. No accelerated erosion or sedimentation was observed in relation to the site or access road. |
2146815 | Primary Facility | 2013-03-07 | Drilling/Alteration | No Violations Noted | logging: TVD 6991' |
2149513 | Primary Facility | 2013-03-14 | Drilling/Alteration | No Violations Noted | @ 10,750' |
2179819 | Primary Facility | 2013-07-01 | Routine/Complete Inspection | No Violations Noted | Well development activites appeared to have been predominatly completed and the wells appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater (as signage indicates) located onsite and it had more than two feet of lined freeboard. Aboeground constructed storage tank had been removed and the containment which had been utilized for the tank was being utilized for roll-off boxes. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2208915 | Primary Facility | 2013-10-01 | Routine/Complete Inspection | No Violations Noted | Well development activites appeared to have been completed and the wells appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater impoundment (as signage indicates) located onsite and it had more than two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2230414 | Primary Facility | 2013-12-04 | Routine/Complete Inspection | No Violations Noted | Well development activites appeared to have been completed and the wells appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater impoundment (as signage indicates) located onsite and it had more than two feet of lined freeboard. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2239660 | Primary Facility | 2014-01-24 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater impoundment (as signage indicates) located onsite and was frozen. |
2258789 | Primary Facility | 2014-04-01 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater impoundment (as signage indicates) located onsite. |
2289506 | Primary Facility | 2014-07-21 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Freshwater impoundment (as signage indicates) located onsite. No accelerated erosion or sedimentation was observed in relation to the site or access road. |
2330942 | Primary Facility | 2014-12-19 | Routine/Complete Inspection | No Violations Noted | |
2390970 | Primary Facility | 2015-07-17 | Routine/Complete Inspection | No Violations Noted | Well appeared ot be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimenation in relation to the site or access road. |
2434105 | Primary Facility | 2015-12-18 | Routine/Complete Inspection | No Violations Noted | Well appeared ot be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimenation in relation to the site or access road. Impoundment located onsite and it contained fluids, access was secured and limited due to chain link fencing. |
2443098 | Primary Facility | 2016-01-25 | Routine/Complete Inspection | No Violations Noted | 2 wells drilled and equipped for production. 2 tanks. ID sign in place. Site snow covered. |
2556064 | Primary Facility | 2017-01-27 | Routine/Complete Inspection | Pending | Brine tanks located onsite within containment. Both the tanks and containment appeared to be in sound condition. The site had been appropriately stabilized and there was no observed accelerated erosion or sedimentstion in relation to the site or access road. |
2597699 | Primary Facility | 2017-05-25 | Site Restoration | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite within containment and the tanks and containment appeared to be in sound condition. Site had been effectively restored and stabilized. There was no observed accelerated erosion or sedimentation in relation to the site or access road |
2670812 | Primary Facility | 2017-12-14 | Routine/Partial/Aerial Inspection | No Violations Noted | At time of inspection, well 590947 drilled and appears equipped for production. Well 591457 also drilled and appears equipped for production. |
2841436 | Primary Facility | 2019-02-15 | Routine/Partial Inspection | No Violations Noted | At the time of inspection, well was producing. The well integrity appeared to be in good condition, with no leaks or spills. Corrosion within the cellar was light, but very rusty. Flow could be heard. Well was being injected with a scale and corrosion inhibitor. The cellar was below ground level and empty. Very little water was on bottom. There was a tubing gauge that was reading 124 psi and a casing gauge reading 295 psi. Annuli were being vented. The well was properly labeled and the Emergency Response sign was posted at the entrance to the site. There were 2 tanks contained within a lined steel dike. 2 line heaters were also being used. There was a hydrate inhibitor being injected here and near the prod. line was methanol being injected. |
For data sources see[8]