If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30823 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.904594,"lon":-79.4523,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Boggs Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 146032 | |
Farm/Lease Name: HOOKS-PHILLIPS UNIT 1M | |
License Status: | |
Spud Date: | |
Permit Date: 2011-05-16 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.904594 | |
Longitude: -79.4523 |
Date | Event |
---|---|
2011-05-16 | New Permit Application |
2011-10-18 | Performed Spud Operation |
2011-10-26 | Drilling Completion |
2011-11-03 | Perforation |
2012-10-26 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SNYDER BROS INC | 7,154.00 | 20 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 79,253.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 38,134.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 29,410.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 23,470.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 17,736.00 | 351 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 15,439.00 | 356 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 14,793.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 13,653.00 | 356 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | SNYDER BROS INC | Produced Fluid | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-049-23127 |
2012 | SNYDER BROS INC | Produced Fluid | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW008 |
2012 | SNYDER BROS INC | Produced Fluid | 333.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2013 | SNYDER BROS INC | Produced Fluid | 96.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2013 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | SNYDER BROS INC | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW009 |
2015 | SNYDER BROS INC | Produced Fluid | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2016 | SNYDER BROS INC | Produced Fluid | 120.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2018 | SNYDER BROS INC | Produced Fluid | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2019 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2011886 | Primary Facility | 2011-10-19 | Routine/Complete Inspection | No Violations Noted | Drill rig was being moved into place, drilling had not as of yet commenced. Drill pit had been properly lined. All E&S controls had been implemented as outlined in the E&S plan located onsite. there was no accelerated eorsion or sedimentation observed in relation to the access road or well-site. |
2012018 | Primary Facility | 2011-10-19 | Drilling/Alteration | No Violations Noted | rig up |
2012748 | Primary Facility | 2011-10-21 | Drilling/Alteration | Violation(s) Noted | Inadequate basket placing on Mine String |
2021868 | Primary Facility | 2011-11-23 | Routine/Complete Inspection | No Violations Noted | Drilling had been completed, well appeared to be equipped for production. Brine tanks onsite and they appeared to be in sound condition. Drill pit still located onsite and it had more than the required two feet of lined freeboard. All erosion controls had been implemented as per the E&S plan and there was no observed accelerated erosion or sedimentation in relation to the access road or well-site. |
2050640 | Primary Facility | 2012-03-14 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation observed in relation to the access road or well-site. The Department recommends that the operator endeavor to complete well-site restoration activities in the near future to take advantage of the upcoming 2012 growing season. |
2084811 | Primary Facility | 2012-07-20 | Site Restoration | No Violations Noted | Drilling had been completed well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Well-site had been regraded and the vegetative cover met the 70% uniform coverage criteria. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. It was noted that the residential pipeline had been excavated and had not been regraded as of the date of the inspection. |
2383144 | Primary Facility | 2015-06-29 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2012748 | 622793 | 10/21/2011 | 2011-10-21 | 78.83COALCSG - Improper coal protective casing and cementing procedures | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
622793 | 276153 | NOV - Notice of Violation | Unresolvable | 2011-11-14 | |||
622793 | 280523 | CACP - Consent Assessment of Civil Penalty | Comply/Closed | 2012-02-13 | 2012-02-13 | $7,250.00 | $7,250.00 |
For data sources see[7]