37-005-29324

Well Details

Well ID: 37-005-29324
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: South Buffalo Township
Operator Name: SNYDER BROS INC
Well Pad ID: 153371
Farm/Lease Name: GOODMAN UNIT 1M
License Status: ACTIVE
Spud Date:
Permit Date: 2007-06-05
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.711550
Longitude: -79.608519

For data sources see[1][2][3]

Well History

Date Event
2007-06-05 New Permit Application
2007-08-20 Performed Spud Operation
2007-08-27 Drilling Completion
2009-03-05 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 SNYDER BROS INC 4309.00 294 0.00 0 0.00 0
2009 SNYDER BROS INC 3609.00 342 0.00 0 0.00 0
2010 SNYDER BROS INC 3,585.00 332 0.00 0 0.00 0
2011 SNYDER BROS INC 2,837.00 307 0.00 0 0.00 0
2012 SNYDER BROS INC 1,440.00 349 0.00 0 0.00 0
2013 SNYDER BROS INC 1,165.00 333 0.00 0 0.00 0
2014 SNYDER BROS INC 1,007.00 313 0.00 0 0.00 0
2015 SNYDER BROS INC 951.00 262 0.00 0 0.00 0
2016 SNYDER BROS INC 1,004.00 315 0.00 0 0.00 0
2017 SNYDER BROS INC 1,075.00 293 0.00 0 0.00 0
2018 SNYDER BROS INC 298.00 308 0.00 0 0.00 0
2019 SNYDER BROS INC 1,012.00 267 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1648246 Primary Facility 2007-08-23 Drilling/Alteration No Violations Noted WELL SPUDDED 8/22/07. PIT LINED, FREEBOARD OK, E&S OK.
2164266 Primary Facility 2013-05-07 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Site had been properly restored after completion of drilling. Inspection was performed as part of the OG-57 waiver review process that was submitted with a drill deeper permit application. The E&S plan as proposed should adequately minimize accelerated erosion and sedimentation provided it is implemented and maintained properly. The operator is reminded that upon completion of the field survey by a qualified individual related to the depth of the drill pit and the seasonal high groundwater table that this information should be included with the E&S plan located onsite and a copy of this information forwarded to WQS Higgins at the address listed on the first page of this inspection report.
2169829 Primary Facility 2013-05-08 Drilling/Alteration No Violations Noted Well operating and properly identified. Well equipped with meter. Well site reclaimed and vegetated.
2211840 Primary Facility 2013-10-10 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Site had been properly restored vegetative cover met the 70% uniform coverage criteria and there was no observed accelerated erosion or sedimentation related to the site or access road.