If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-003-21567 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.497261,"lon":-79.796453,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Allegheny | |
Municipality: Penn Hills Township | |
Operator Name: HUNTLEY & HUNTLEY INC | |
Well Pad ID: | |
Farm/Lease Name: MULLEN UNIT 1 | |
License Status: ACTIVE | |
Spud Date: | |
Permit Date: 2002-07-25 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.497261 | |
Longitude: -79.796453 |
Date | Event |
---|---|
2002-07-25 | New Permit Application |
2002-10-22 | Performed Spud Operation |
2002-10-30 | Drilling Completion |
2004-06-18 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2002 | HUNTLEY & HUNTLEY INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2003 | HUNTLEY & HUNTLEY INC | 534.00 | 30 | 0.00 | 0 | 0.00 | 0 |
2005 | HUNTLEY & HUNTLEY INC | 6818 | 365 | 0.00 | 0 | 0.00 | 0 |
2006 | HUNTLEY & HUNTLEY INC | 4991.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2008 | HUNTLEY & HUNTLEY INC | 2664.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2009 | HUNTLEY & HUNTLEY INC | 2,822.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2010 | HUNTLEY & HUNTLEY INC | 2,356.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2011 | HUNTLEY & HUNTLEY INC | 2,124.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | HUNTLEY & HUNTLEY INC | 2,093.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | HUNTLEY & HUNTLEY INC | 1,648.65 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | HUNTLEY & HUNTLEY INC | 2,609.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | HUNTLEY & HUNTLEY INC | 1,537.00 | 273 | 0.00 | 0 | 0.00 | 0 |
2016 | HUNTLEY & HUNTLEY INC | 825.00 | 243 | 0.00 | 0 | 0.00 | 0 |
2017 | HUNTLEY & HUNTLEY INC | 850.00 | 290 | 0.00 | 0 | 0.00 | 0 |
2018 | HUNTLEY & HUNTLEY INC | 725.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2003 | HUNTLEY & HUNTLEY INC | Brine | 464.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0095443 |
2003 | HUNTLEY & HUNTLEY INC | Brine | 464.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0091472 |
2005 | HUNTLEY & HUNTLEY INC | Brine | 440.00 Bbl | Municipal Sewage Treatment Plant | PA0026255 |
2005 | HUNTLEY & HUNTLEY INC | Brine | 145.00 Bbl | Other | |
2008 | HUNTLEY & HUNTLEY INC | Brine | 130.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0095273 |
2008 | HUNTLEY & HUNTLEY INC | Brine | 205.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0091472 |
2013 | HUNTLEY & HUNTLEY INC | Produced Fluid | 250 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2013 | HUNTLEY & HUNTLEY INC | Produced Fluid | 250.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2017 | HUNTLEY & HUNTLEY INC | Produced Fluid | 100.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2018 | HUNTLEY & HUNTLEY INC | Produced Fluid | 200.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1160415 | Primary Facility | 2002-08-16 | Routine/Complete Inspection | No Violations Noted | Accesses off a curve on Hulton Rd., location stoney, access rocked & crowned. Pit: excavated loc. Bench is staked. Site bench awaits rig. Shoulder slope moderate. |
1238253 | Primary Facility | 2003-05-27 | Routine/Complete Inspection | No Violations Noted | Six tanks are within the diking system, brine & oil tanks. Well is metered, equipped. Some storage of pipe equipt. and alcohol & foaming agents at bench area for well use. Restoration uniform revegetating. Access is stoned & graveled. Also a gated entrance here. Well tagged. |
1902427 | Primary Facility | 2010-06-24 | Routine/Complete Inspection | No Violations Noted | On June 24th, 2010 I conducted a routine inspection of the above site. Drilling was completed October 30th, 2002. The well was in production. The access road was in good condition. A well tag was present. the site was well vegetated and no accelerated erosion was observed. There was a lot of excess drilling supplies being stored onsite including drill rods, casing, gas line, drums, etc. There was also a diked area containing 6 storage tanks, 3 oil and 3 brine. The containment area was lined with a 30 mil plastic liner. There was 6-10 inches of oil and water inside the diked area from spillage and sloppy materials handling. Another storage tank located outside of the diked area that contained white water. A meeting was set for 6/28 with the operator to discuss the issues on site. |
1902437 | Primary Facility | 2010-06-28 | Routine/Complete Inspection | No Violations Noted | On June 28th, 2010 I met with Huntley & Huntley representative John Hodson onsite to discuss the issues from the 06/24/2010 inspection. The operator agreed to have all excess material removed from site. All liquids will be removed from the diked area and put back into tanks or disposed of properly. The tank outside of the containment area will have a dike constructed around it in case it is used for oil storage in the future. All work and site cleanup is to be completed in a timely fashion. |
1902447 | Primary Facility | 2010-07-22 | Routine/Complete Inspection | No Violations Noted | On July 22nd, 2010 I met with Huntley & Huntley representative John Hodson onsite to discuss the issues and progress made from the 06/28/2010 inspection. All excess material had been removed from site. All liquids from the containment area had been removed and a general cleanup had taken place. The tank that was located outside of the dike was now in a lined containment area surrounded by a dike. A tracking program/ sign in sheet was being implemented to create accountability for the site and to prevent future materials handling problems. |
1910858 | Primary Facility | 2010-08-12 | Routine/Complete Inspection | No Violations Noted | On August 12th, 2010 I conducted a follow up inspection of the above site. Excess rain water from the diked area was being pumped into the tanks. A stone walkway was constructed around the tanks in the dike. Vegetation was coming in nicely on the newly seeded areas. The operator should continue to inspect and monitor materials handling at the site. |
1940324 | Primary Facility | 2010-12-28 | Routine/Complete Inspection | No Violations Noted | On December 28th, 2010 I conducted a follow up inspection of the above site in response to clean up activities that occurred over the summer months. The tank storage area looked good. No new spills or leaks were observed. The diked area was now surrounded by a security fence. Extra signage was added. The operator should continue to inspect and monitor materials handling at the site. |
For data sources see[7]