34-111-24467

Well Details

Well ID: 34-111-24467
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Franklin Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: US-OH-000936
Farm/Lease Name: WEBB SOUTH
License Status: Drilling
License Date: 2014-05-01
Spud Date: 2014-05-09
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Horizontal
Latitude: 39.707344665
Longitude: -81.25008242

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-05-01 Proposed Formations:POINT PLEASANT, Issued Date:5/1/2014, Expired Date:4/30/2016 12:00:00 PM, Drilling unit acres:614.5, Proposed Well Type:OG, Proposed Well Class:EDPW
Change of Owner 2015-02-13 Operator changed from 8856, HALL DRILLING LLC (OIL & GAS) to 8943, ANTERO RESOURCES CORPORATION
Construction Permit Expires 2016-04-30
Record Last Modified 2017-10-23

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1400171467 2014-05-15 Casing String Witnessed No Violations 05/13/14 they were beginning to run the surface casing which shall be weld connections with a casing shoe ran and 3 centralizers to be used. 05/15/2014 493 of 20 .375 wall weld connections surface pipe was ran with 3 centralizers used and Baker Hughes cement services on location to cement the casing with 507 sacks of Type 1 2% calcium .25# pound per sack flake with circulation established prior to cementing and 30 barrels of good cement returns to surface, due to the type of rig no cement head can be ran so the casing shall be pressure tested at a later date.
1423586377 2014-05-23 Drill / Deepen / Reopen No Violations Baker Hughes pressure tested 20casing to 300 psi. for 30 minutes. Test passed.
1521230847 2018-03-15 Drill / Deepen / Reopen No Violations On this day, I found the well equipped with 20 inch diameter sealed casing at the surface. There is (1) well in production, and (3) wells that have surface casing set, but were never completed. The inactive wells have sealed casing at the surface. All wells have concrete barriers surrounding them. The facility is gated with proper signage. There is a north pad and a south pad. The south pad contains the wells, along with (2) 400 barrel steel tanks within containment, on the back right-side. The north pad contains the midstream facility, (1) gas processing unit within containment, and (1) 400 barrel steel storage tank, also within containment. There are (2) additional 400 barrel steel tanks within containment, along County Road 16, near the lease road entrance. (Lat. 39.70921 Long. -81.25219) It will be noted that I spoke with Antero representative, Jonah Turner, during my inspection, and informed him to make sure that his operators have their wellheads identified with proper signage.