If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-131-20147 | | Well ID: 37-131-20147 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="14" | {{#display_map: 41.625047, -75.937856 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: [[Lemon Township, | + | | State: Pennsylvania |
+ | |- | ||
+ | | County: [[Wyoming_County,_Pennsylvania|Wyoming]] | ||
+ | |- | ||
+ | | Municipality: [[Lemon Township,_Wyoming_County,_Pennsylvania|Lemon Township]] | ||
|- | |- | ||
| Operator Name: [[CHIEF OIL & GAS LLC]] | | Operator Name: [[CHIEF OIL & GAS LLC]] | ||
|- | |- | ||
− | | Well Pad ID: [[ | + | | Well Pad ID: [[145704]] |
|- | |- | ||
| Farm/Lease Name: GARRISON UNIT 1H | | Farm/Lease Name: GARRISON UNIT 1H | ||
|- | |- | ||
− | | | + | | License Status: Active |
|- | |- | ||
− | | | + | | Spud Date: 04/01/2011 |
|- | |- | ||
− | | | + | | Permit Date: 3/25/2011 |
|- | |- | ||
− | | Unconventional: | + | | Unconventional Well: Y |
|- | |- | ||
− | | Horizontal | + | | Configuration: Horizontal Well |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| Latitude: 41.625047 | | Latitude: 41.625047 | ||
|- | |- | ||
− | | Longitude: -75. | + | | Longitude: -75.937856 |
− | |||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
+ | !scope="col" | Water Production Days | ||
|- | |- | ||
− | | 2011 | + | | 2011 |
− | | style="text-align:right;" | 0. | + | | [[CHIEF OIL & GAS LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2012 | ||
+ | | [[CHIEF OIL & GAS LLC]] | ||
+ | | style="text-align: right;" | 2,064,665.00 | ||
+ | | style="text-align: right;" | 153 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2013 |
− | | style="text-align:right;" | | + | | [[CHIEF OIL & GAS LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 3,705,497.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 361 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2014 | ||
+ | | [[CHIEF OIL & GAS LLC]] | ||
+ | | style="text-align: right;" | 746,948.00 | ||
+ | | style="text-align: right;" | 218 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2015 |
− | | style="text-align:right;" | | + | | [[CHIEF OIL & GAS LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 992,329.35 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 364 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2016 | ||
+ | | [[CHIEF OIL & GAS LLC]] | ||
+ | | style="text-align: right;" | 804,783.09 | ||
+ | | style="text-align: right;" | 363 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | style="text-align:right;" | | + | | [[CHIEF OIL & GAS LLC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 487,149.46 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2018 | ||
+ | | [[CHIEF OIL & GAS LLC]] | ||
+ | | style="text-align: right;" | 589,074.21 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[CHIEF OIL & GAS LLC]] | |
− | + | | style="text-align: right;" | 78,404.61 | |
− | + | | style="text-align: right;" | 84 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | + | | style="text-align: right;" | 0.00 | |
− | + | | style="text-align: right;" | 0 | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
− | | style="text-align:right;" | 0. | ||
− | | style="text-align:right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | 2011- | + | | 2011-S01 |
− | | | + | | Drill Cuttings (in Tons) |
− | | style="text-align:right;" | 19.11 | + | | style="text-align: right;" | 19.11 Tons |
− | |||
| LANDFILL | | LANDFILL | ||
| 100955 | | 100955 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2011-S01 | |
− | | 2011- | + | | Drill Cuttings (in Tons) |
− | | | + | | style="text-align: right;" | 960.39 Tons |
− | | style="text-align:right;" | 960.39 | ||
− | |||
| LANDFILL | | LANDFILL | ||
| 301626 | | 301626 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2011-S01 | |
− | | 2011- | + | | Drilling Fluid Waste (in Barrels) |
− | | | + | | style="text-align: right;" | 480.00 Bbl |
− | | style="text-align:right;" | 480. | ||
− | |||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| EPA ID: 748-163 | | EPA ID: 748-163 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2011-S01 | |
− | | 2011- | + | | Fracing Fluid Waste (in Barrels) |
− | | | + | | style="text-align: right;" | 780.00 Bbl |
− | | style="text-align:right;" | 780. | ||
− | |||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0008451 | | PA0008451 | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | + | | 2011-S02 | |
− | | 2011- | + | | Drill Cuttings (in Tons) |
− | | | + | | style="text-align: right;" | 15.82 Tons |
− | | style="text-align:right;" | 15.82 | ||
− | |||
| LANDFILL | | LANDFILL | ||
| 301626 | | 301626 | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 2011-S02 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 7,773.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2012-S01 |
− | | | + | | Fracing Fluid Waste (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 6,364.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | | + | |- |
+ | | 2012-S02 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 930.80 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | |||
|- | |- | ||
+ | | 2013-S01 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 874.40 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2013-S02 |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 544.00 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2014-S01 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 169.00 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
+ | |- | ||
+ | | 2014-S02 | ||
+ | | Produced Fluid (in Barrels) | ||
+ | | style="text-align: right;" | 2,097.19 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
+ | | 2015-S01 | ||
+ | | Fracing Fluid Waste (in Barrels) | ||
+ | | style="text-align: right;" | 1,260.00 Bbl | ||
+ | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
+ | | WMGR123 | ||
|- | |- | ||
− | | | + | | 2015-S01 |
− | | | + | | Produced Fluid (in Barrels) |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 377.69 Bbl |
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
− | |- | + | | 2015-S02 |
− | | | + | | Produced Fluid (in Barrels) |
− | + | | style="text-align: right;" | 247.80 Bbl | |
− | | style="text-align:right;" | | ||
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
− | |- | + | | 2016-S01 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | + | | style="text-align: right;" | 278.88 Bbl | |
− | | style="text-align:right;" | | ||
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
− | |- | + | | 2016-S02 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | + | | style="text-align: right;" | 203.12 Bbl | |
− | | style="text-align:right;" | | ||
− | |||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2017-M01 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 29.36 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2017-M05 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 24.29 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
+ | | 2017-M11 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 21.38 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
|- | |- | ||
− | | | + | | 2018-M01 |
− | | | + | | Produced Fluid (in Barrels) RWC 802 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 29.80 Bbl |
− | + | | REUSE (AT WELL PAD) | |
− | | REUSE | ||
| | | | ||
− | | REUSE | + | |- |
+ | | 2018-M02 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 27.46 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
+ | |- | ||
+ | | 2018-M10 | ||
+ | | Produced Fluid (in Barrels) RWC 802 | ||
+ | | style="text-align: right;" | 25.95 Bbl | ||
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
− | + | !scope="col" | Inspection Comments | |
− | !scope="col" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1956723 | | 1956723 | ||
− | | | + | | Primary Facility |
+ | | 03/11/2011 | ||
+ | | Routine/Complete Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 1958644 | | 1958644 | ||
− | | 2011- | + | | Primary Facility |
+ | | 03/14/2011 | ||
+ | | Follow-up Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 1964809 | | 1964809 | ||
− | | | + | | Primary Facility |
+ | | 04/11/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| Ziggenfuss moved in 4/1/2011, drilled in conductor- no cement, then drilled to 517' Rig H&P 285 air drilling depth is 616', not drilling now - rig problems | | Ziggenfuss moved in 4/1/2011, drilled in conductor- no cement, then drilled to 517' Rig H&P 285 air drilling depth is 616', not drilling now - rig problems | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1964976 | | 1964976 | ||
− | | | + | | Primary Facility |
+ | | 04/11/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| Will return to investigate standing water in ponds at the entrance to the pad. The water is black and is seperated by culvert. Pond on south side of culvert is draining into ground. | | Will return to investigate standing water in ponds at the entrance to the pad. The water is black and is seperated by culvert. Pond on south side of culvert is draining into ground. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1965272 | | 1965272 | ||
− | | 2011- | + | | Primary Facility |
+ | | 04/13/2011 | ||
+ | | Follow-up Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| Collected sample from sediment trap and wetland area outside of pad. | | Collected sample from sediment trap and wetland area outside of pad. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1966404 | | 1966404 | ||
− | | | + | | Primary Facility |
+ | | 04/14/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| BOP tested 4/13/2011 | | BOP tested 4/13/2011 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1967899 | | 1967899 | ||
− | | | + | | Primary Facility |
+ | | 04/25/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 1968294 | | 1968294 | ||
− | | | + | | Primary Facility |
+ | | 04/25/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| H&P 285, checked drillers log, at 10072', TD will be 12774' | | H&P 285, checked drillers log, at 10072', TD will be 12774' | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1969132 | | 1969132 | ||
− | | | + | | Primary Facility |
+ | | 04/26/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| On site to review a copy of the PPC plan and conduct an inspection of the solids handling area. The PPC plan could not be located at the site. I obtained a copy of the PPC plan at a pre-construction meeting back in Feburary. I informed Rich Adams and Matt Barch of Chief of the revisons of the plan that need to be implemented. There were no violations observed during the inspection. | | On site to review a copy of the PPC plan and conduct an inspection of the solids handling area. The PPC plan could not be located at the site. I obtained a copy of the PPC plan at a pre-construction meeting back in Feburary. I informed Rich Adams and Matt Barch of Chief of the revisons of the plan that need to be implemented. There were no violations observed during the inspection. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1969660 | | 1969660 | ||
− | | | + | | Primary Facility |
+ | | 05/02/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| well is done - company man is not on site | | well is done - company man is not on site | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1970791 | | 1970791 | ||
− | | | + | | Primary Facility |
+ | | 05/05/2011 | ||
+ | | Complaint Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1970847 | | 1970847 | ||
− | | | + | | Primary Facility |
+ | | 05/05/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
− | | done drilling on 4/28/2011 cemented on 4/29/2011 | + | | done drilling on 4/28/2011 cemented on 4/29/2011 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1972748 | | 1972748 | ||
− | | 2011- | + | | Primary Facility |
+ | | 05/11/2011 | ||
+ | | Follow-up Inspection | ||
| Outstanding Violations - No Viols Req'd | | Outstanding Violations - No Viols Req'd | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1975452 | | 1975452 | ||
− | | 2011- | + | | Primary Facility |
+ | | 05/22/2011 | ||
+ | | Follow-up Inspection | ||
| Outstanding Violations - Viols Req'd | | Outstanding Violations - Viols Req'd | ||
| Results for the Oil & Grease sample collected on 5/5/2011 indicated a positive detection of Oil & Grease in the water (8.1 mg/L). | | Results for the Oil & Grease sample collected on 5/5/2011 indicated a positive detection of Oil & Grease in the water (8.1 mg/L). | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1976387 | | 1976387 | ||
− | | | + | | Primary Facility |
+ | | 05/26/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| site & well looks good - very little water in cellar Chief released rig | | site & well looks good - very little water in cellar Chief released rig | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1977008 | | 1977008 | ||
− | | 2011- | + | | Primary Facility |
+ | | 06/01/2011 | ||
+ | | Follow-up Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| Outlet to sediment trap at entrance has been modified. Water had been removed. Outlet is dry and appears to be draining sufficiently. | | Outlet to sediment trap at entrance has been modified. Water had been removed. Outlet is dry and appears to be draining sufficiently. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1979731 | | 1979731 | ||
− | | 2011- | + | | Primary Facility |
+ | | 06/13/2011 | ||
+ | | Follow-up Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 1980320 | | 1980320 | ||
− | | | + | | Primary Facility |
+ | | 06/13/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| preparing to frac - weel head and lots of frac tanks, site looks good | | preparing to frac - weel head and lots of frac tanks, site looks good | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1985130 | | 1985130 | ||
− | | | + | | Primary Facility |
+ | | 07/01/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| IPS - integrated production services trucks on site, no comp. man, fracing | | IPS - integrated production services trucks on site, no comp. man, fracing | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1986266 | | 1986266 | ||
− | | | + | | Primary Facility |
+ | | 07/07/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | |||
− | |||
− | |||
| | | | ||
− | |||
|- | |- | ||
| 1994470 | | 1994470 | ||
− | | | + | | Primary Facility |
+ | | 08/09/2011 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| Well fraced on Sat and Sun (8/6 & 8/7/2011). | | Well fraced on Sat and Sun (8/6 & 8/7/2011). | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1995320 | | 1995320 | ||
− | | | + | | Primary Facility |
+ | | 08/12/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| Done flowing back after frac, plastic containment, tanks, and some equip. still on site. | | Done flowing back after frac, plastic containment, tanks, and some equip. still on site. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2004561 | | 2004561 | ||
− | | | + | | Primary Facility |
+ | | 09/22/2011 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| Tanks still on site, as well as a dumpster and some sand. | | Tanks still on site, as well as a dumpster and some sand. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2030254 | | 2030254 | ||
− | | | + | | Primary Facility |
+ | | 12/27/2011 | ||
+ | | Routine/Complete Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
| Erosion control blankets were installed during a seperate inspection on 12/29/11. The area being blanketed was an area used for staging and parking vehicles and was not the area near the gate which has the significant erosion problems. Further blanketing was to be employed at the area near the gate for temporary stabilization until the area can be corrected in the Spring. | | Erosion control blankets were installed during a seperate inspection on 12/29/11. The area being blanketed was an area used for staging and parking vehicles and was not the area near the gate which has the significant erosion problems. Further blanketing was to be employed at the area near the gate for temporary stabilization until the area can be corrected in the Spring. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2031097 | | 2031097 | ||
− | | | + | | Primary Facility |
+ | | 12/29/2011 | ||
+ | | Complaint Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| A reading of 4 psi after 20 minutes on the 5 x 9 annulus. The well was shut-in for 24 hour monitoring. | | A reading of 4 psi after 20 minutes on the 5 x 9 annulus. The well was shut-in for 24 hour monitoring. | ||
+ | |- | ||
+ | | 2031102 | ||
+ | | Primary Facility | ||
+ | | 12/30/2011 | ||
+ | | Follow-up Inspection | ||
+ | | No Violations Noted | ||
+ | | A reading of 84 psi on the 5 x 9 annulus and 3.5 on the 9 x 13 after 24 hour shut-in. | ||
+ | |- | ||
+ | | 2031572 | ||
+ | | Primary Facility | ||
+ | | 01/05/2012 | ||
+ | | Administrative/File Review | ||
+ | | No Violations Noted | ||
+ | | Reviewed E & S Inspection Reports for 10/25 thru 11/14/2011. Reports adequately meet requirements of permit conditions. | ||
+ | |- | ||
+ | | 2031935 | ||
+ | | Primary Facility | ||
+ | | 12/29/2011 | ||
+ | | Complaint Inspection | ||
+ | | No Violations Noted | ||
+ | | DEP Reps - Ryan Klemish, Matt Shope, (Eric Rooney arrived late) met with Chief reps. Rich Adams, Ralph Larsen, and Jon Hafer.Arrived at 10:35 AM. There are 2 annulus' - not shut in. Installed 100 psi pressure guages. After 20 min., the 5 1/2" x 9 5/8" has 3 psi and the 9 5/8" x 13 3/8"? has 0 psi. After 1 hr 17 min, the 5 1/2" x 9 5/8" has 10 psi and ?9 5/8" x 13 3/8"? has o psi. Chief took an isotopic sample. | ||
+ | |- | ||
+ | | 2035641 | ||
+ | | Primary Facility | ||
+ | | 01/20/2012 | ||
+ | | Follow-up Inspection | ||
+ | | No Violations Noted | ||
+ | | | ||
+ | |- | ||
+ | | 2036680 | ||
+ | | Primary Facility | ||
+ | | 01/24/2012 | ||
+ | | Administrative/File Review | ||
+ | | No Violations Noted | ||
+ | | Response to NOV for Inspection ID: 2030254 | ||
+ | |- | ||
+ | | 2109049 | ||
+ | | Primary Facility | ||
+ | | 10/16/2012 | ||
+ | | Follow-up Inspection | ||
+ | | No Violations Noted | ||
+ | | Producing well. No barriers around well head. | ||
+ | |- | ||
+ | | 2181691 | ||
+ | | Primary Facility | ||
+ | | 07/09/2013 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
| | | | ||
+ | |- | ||
+ | | 2505878 | ||
+ | | Primary Facility | ||
+ | | 2016-07-27 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
| | | | ||
+ | |- | ||
+ | | 2546002 | ||
+ | | Primary Facility | ||
+ | | 2016-12-19 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
| | | | ||
|- | |- | ||
+ | | 2713312 | ||
+ | | Primary Facility | ||
+ | | 2018-03-28 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | Arrived at site at: 08:30. Weather: Overcast, cold ~ 35 degs. Onsite to perform routine inspections of wells on pad. A total of (9) wells were present on pad. All (9) wells were in production at time of inspection. All wells Prod. tree top press. "PTTP", Prod. line press. "PLP" and Prod. casing press. "PCP" were being monitored by wireless data sending units and/or analog gauges. (See individual well pressures and observations listed below.) | ||
+ | - All wells had (2) annular vents present labeled (13 3/8"x 9 5/8") and (9 5/8"x 5 1/2"). All annular vents were open and venting to (3) poly vent tanks "VTs" via shared 2" vent lines. I labeled the VTs with a black magic marker at time of inspection. (#1 VT shares the 2H, 5H, 3H & N1H annular vents. #2 VT shares the N4H, N2H & N3H annular vents. #3 VT shares the 1H & 4H annular vents.) I performed gas checks at VT lid openings using a Altair 5X gas meter calibrated on 3/5/18. Gas checks showed: VT #1 = 48% LEL, 2% CH4; VT #2 = 10% LEL, 0% CH4; VT #3 = 40% LEL, 2% CH4. | ||
+ | |- | ||
+ | | 2743686 | ||
+ | | Primary Facility | ||
+ | | 2018-06-12 | ||
+ | | Routine/Complete Inspection | ||
+ | | No Violations Noted | ||
+ | | "Pump-down" operations were being conducted by Halliburton Oilfield Services on the 1H well. There were no violations noted. If you have any questions, please contact me. | ||
|- | |- | ||
− | | | + | | 2804612 |
− | | | + | | Primary Facility |
+ | | 2018-11-14 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
− | | | + | | Chief Oil & Gas submitted a Notice of Termination (NOT) for the Garrison pad covered under ESX29-131-17-0003. The NOT was received by the Department on 9/27/18. Arrived onsite for at 10:35; the weather was ~30°F and calm. Several frozen puddles were on the pad surface. |
+ | |||
+ | There were 9 properly tagged Marcellus wells staged for production. Most of the well cellars were filled with water; no bubbling was observed. There were 9 GPUs and 1 compressor onsite and in secondary containment. There was approx. 6 to 12 inches of mostly frozen water in the produced water tank secondary containment. Secondary containment also remained around the wells. I contacted Chris Vassallo via email and was informed on 11/16/18 that the containment is there due to scheduled maintenance on one of the wells. | ||
+ | |||
+ | The site was well vegetated and appeared stable. All PCSM had been constructed and no temporary E&S BMPs remained. | ||
+ | |||
+ | It is recommended that secondary containment around the produced water tanks be monitored and the water removed a | ||
+ | |- | ||
+ | |} | ||
+ | ==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
+ | |- | ||
+ | | 1956723 | ||
+ | | 606430 | ||
+ | | 03/11/2011 | ||
+ | | 03/14/2011 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Environmental Health & Safety | ||
| | | | ||
+ | |- | ||
+ | | 1956723 | ||
+ | | 606431 | ||
+ | | 03/11/2011 | ||
+ | | 03/14/2011 | ||
+ | | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | ||
+ | | Environmental Health & Safety | ||
| | | | ||
+ | |- | ||
+ | | 1956723 | ||
+ | | 606442 | ||
+ | | 03/11/2011 | ||
+ | | 03/14/2011 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | Administrative | ||
| | | | ||
|- | |- | ||
+ | | 1970791 | ||
+ | | 610311 | ||
+ | | 05/05/2011 | ||
+ | | 06/01/2011 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Environmental Health & Safety | ||
+ | | | ||
|- | |- | ||
− | | | + | | 1970791 |
− | | | + | | 610312 |
− | | | + | | 05/05/2011 |
− | | | + | | 06/01/2011 |
− | + | | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | |
− | + | | Environmental Health & Safety | |
| | | | ||
+ | |- | ||
+ | | 1975452 | ||
+ | | 611872 | ||
+ | | 05/22/2011 | ||
+ | | 06/13/2011 | ||
+ | | 78.66A - Failure to report release of substance threatening or causing pollution | ||
+ | | Administrative | ||
| | | | ||
+ | |- | ||
+ | | 1975452 | ||
+ | | 612403 | ||
+ | | 05/22/2011 | ||
+ | | 06/13/2011 | ||
+ | | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | ||
+ | | Environmental Health & Safety | ||
| | | | ||
|- | |- | ||
+ | | 2030254 | ||
+ | | 628115 | ||
+ | | 12/27/2011 | ||
+ | | 01/20/2012 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Environmental Health & Safety | ||
+ | | Erosion caused by vehicular traffic near gate to pad. Area was noted in an inspection on 7/7/11 and was not addressed. Area is noted in the operator's E & S Inspection Reports as "unsatisfactory". | ||
+ | |- | ||
+ | |} | ||
+ | ==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
|- | |- | ||
− | | | + | | 628115 |
− | | | + | | 278937 |
− | | | + | | NOV - Notice of Violation |
− | |||
| | | | ||
| | | | ||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =Oil and Gas Compliance Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
|- | |- | ||
+ | | 1 | ||
+ | | 08/07/2011 | ||
+ | | 08/07/2011 | ||
+ | | style="text-align: right;" | 7858.00 | ||
+ | | style="text-align: right;" | 1,020,138.0 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="20"| 1 | ||
+ | | rowspan="5"| Super Scale Control TSC | ||
+ | | rowspan="5"| Superior Well Services | ||
+ | | rowspan="5"| Scale Inhibitor | ||
+ | | 1,2,4-Butanetricarboxylic acid, 2-phosphono- | ||
+ | | 37971-36-1 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | |||
− | |||
− | |||
− | |||
| | | | ||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Anionic Copolymer | ||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
+ | | 1,2-Propylene glycol | ||
+ | | 57-55-6 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | 0.04 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | | Anionic Polymer |
− | |||
− | |||
− | |||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| Sand (Proppant) | ||
+ | | rowspan="2"| Superior Well Services | ||
+ | | rowspan="2"| Propping Agent | ||
| | | | ||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
+ | | Quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 99.90 | ||
+ | | style="text-align: right;" | 10.38 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="1"| Water |
− | | | + | | rowspan="1"| |
− | | | + | | rowspan="1"| Base Fluid |
− | + | | Water | |
− | |||
− | |||
− | |||
| | | | ||
+ | | style="text-align: right;" | 100.00 | ||
+ | | style="text-align: right;" | 89.37 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="5"| KR-153SL | ||
+ | | rowspan="5"| Superior Well Services | ||
+ | | rowspan="5"| Biocide | ||
| | | | ||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Polyethylene glycol | ||
+ | | 25322-68-3 | ||
+ | | style="text-align: right;" | 50.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Diethylene glycol | ||
+ | | 111-46-6 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 1.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
+ | | 2,2-Dibromo-3-nitrilopropionamide | ||
+ | | 10222-01-2 | ||
+ | | style="text-align: right;" | 20.00 | ||
+ | | style="text-align: right;" | 0.02 | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
− | | | + | |- valign="top" |
− | | | + | | rowspan="5"| WFR-3B |
− | | | + | | rowspan="5"| Superior Well Services |
+ | | rowspan="5"| Friction Reducer | ||
| | | | ||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Distillates, petroleum, hydrotreated light | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | 0.15 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Ethoxylated C12-16 alcohols | ||
+ | | 68551-12-2 | ||
+ | | style="text-align: right;" | 4.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | Stoddard solvent | ||
+ | | 8052-41-3 | ||
+ | | style="text-align: right;" | 10.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | | 1,2-Propylene glycol | ||
+ | | 57-55-6 | ||
+ | | style="text-align: right;" | 25.00 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="2"| FE OXCLEAR | ||
+ | | rowspan="2"| Superior Well Services | ||
+ | | rowspan="2"| Oxygen Scavenger | ||
+ | | Ammonium bisulfite | ||
+ | | 10192-30-0 | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | | ||
+ | |- | ||
| | | | ||
| | | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
+ | | style="text-align: right;" | | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title =FracFocus Fracking Chemicals Database |
− | + | | date = 2019-04-02 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | accessdate = 2019-06-19 }}</ref> |
− | | accessdate = | + | ==References== |
− | == References == | + | <references/> |
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
+ | [[Category:FracFocus]] |
Well ID: 37-131-20147 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.625047,"lon":-75.937856,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Lemon Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 145704 | |
Farm/Lease Name: GARRISON UNIT 1H | |
License Status: Active | |
Spud Date: 04/01/2011 | |
Permit Date: 3/25/2011 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.625047 | |
Longitude: -75.937856 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 2,064,665.00 | 153 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 3,705,497.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 746,948.00 | 218 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 992,329.35 | 364 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 804,783.09 | 363 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 487,149.46 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 589,074.21 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 78,404.61 | 84 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2011-S01 | Drill Cuttings (in Tons) | 19.11 Tons | LANDFILL | 100955 |
2011-S01 | Drill Cuttings (in Tons) | 960.39 Tons | LANDFILL | 301626 |
2011-S01 | Drilling Fluid Waste (in Barrels) | 480.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2011-S01 | Fracing Fluid Waste (in Barrels) | 780.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011-S02 | Drill Cuttings (in Tons) | 15.82 Tons | LANDFILL | 301626 |
2011-S02 | Fracing Fluid Waste (in Barrels) | 7,773.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S01 | Fracing Fluid Waste (in Barrels) | 6,364.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-S02 | Produced Fluid (in Barrels) | 930.80 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Produced Fluid (in Barrels) | 874.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Produced Fluid (in Barrels) | 544.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Produced Fluid (in Barrels) | 169.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Produced Fluid (in Barrels) | 2,097.19 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Fracing Fluid Waste (in Barrels) | 1,260.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015-S01 | Produced Fluid (in Barrels) | 377.69 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 247.80 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 278.88 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 203.12 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 29.36 Bbl | REUSE (AT WELL PAD) | |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 24.29 Bbl | REUSE (AT WELL PAD) | |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 21.38 Bbl | REUSE (AT WELL PAD) | |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 29.80 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 27.46 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 25.95 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1956723 | Primary Facility | 03/11/2011 | Routine/Complete Inspection | Violation(s) Noted | |
1958644 | Primary Facility | 03/14/2011 | Follow-up Inspection | No Violations Noted | |
1964809 | Primary Facility | 04/11/2011 | Drilling/Alteration | No Violations Noted | Ziggenfuss moved in 4/1/2011, drilled in conductor- no cement, then drilled to 517' Rig H&P 285 air drilling depth is 616', not drilling now - rig problems |
1964976 | Primary Facility | 04/11/2011 | Routine/Complete Inspection | No Violations Noted | Will return to investigate standing water in ponds at the entrance to the pad. The water is black and is seperated by culvert. Pond on south side of culvert is draining into ground. |
1965272 | Primary Facility | 04/13/2011 | Follow-up Inspection | No Violations Noted | Collected sample from sediment trap and wetland area outside of pad. |
1966404 | Primary Facility | 04/14/2011 | Drilling/Alteration | No Violations Noted | BOP tested 4/13/2011 |
1967899 | Primary Facility | 04/25/2011 | Routine/Complete Inspection | No Violations Noted | |
1968294 | Primary Facility | 04/25/2011 | Drilling/Alteration | No Violations Noted | H&P 285, checked drillers log, at 10072', TD will be 12774' |
1969132 | Primary Facility | 04/26/2011 | Routine/Complete Inspection | No Violations Noted | On site to review a copy of the PPC plan and conduct an inspection of the solids handling area. The PPC plan could not be located at the site. I obtained a copy of the PPC plan at a pre-construction meeting back in Feburary. I informed Rich Adams and Matt Barch of Chief of the revisons of the plan that need to be implemented. There were no violations observed during the inspection. |
1969660 | Primary Facility | 05/02/2011 | Drilling/Alteration | No Violations Noted | well is done - company man is not on site |
1970791 | Primary Facility | 05/05/2011 | Complaint Inspection | Violation(s) Noted | |
1970847 | Primary Facility | 05/05/2011 | Drilling/Alteration | No Violations Noted | done drilling on 4/28/2011 cemented on 4/29/2011 |
1972748 | Primary Facility | 05/11/2011 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | |
1975452 | Primary Facility | 05/22/2011 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Results for the Oil & Grease sample collected on 5/5/2011 indicated a positive detection of Oil & Grease in the water (8.1 mg/L). |
1976387 | Primary Facility | 05/26/2011 | Routine/Complete Inspection | No Violations Noted | site & well looks good - very little water in cellar Chief released rig |
1977008 | Primary Facility | 06/01/2011 | Follow-up Inspection | No Violations Noted | Outlet to sediment trap at entrance has been modified. Water had been removed. Outlet is dry and appears to be draining sufficiently. |
1979731 | Primary Facility | 06/13/2011 | Follow-up Inspection | No Violations Noted | |
1980320 | Primary Facility | 06/13/2011 | Routine/Complete Inspection | No Violations Noted | preparing to frac - weel head and lots of frac tanks, site looks good |
1985130 | Primary Facility | 07/01/2011 | Drilling/Alteration | No Violations Noted | IPS - integrated production services trucks on site, no comp. man, fracing |
1986266 | Primary Facility | 07/07/2011 | Routine/Complete Inspection | No Violations Noted | |
1994470 | Primary Facility | 08/09/2011 | Drilling/Alteration | No Violations Noted | Well fraced on Sat and Sun (8/6 & 8/7/2011). |
1995320 | Primary Facility | 08/12/2011 | Routine/Complete Inspection | No Violations Noted | Done flowing back after frac, plastic containment, tanks, and some equip. still on site. |
2004561 | Primary Facility | 09/22/2011 | Routine/Complete Inspection | No Violations Noted | Tanks still on site, as well as a dumpster and some sand. |
2030254 | Primary Facility | 12/27/2011 | Routine/Complete Inspection | Violation(s) Noted | Erosion control blankets were installed during a seperate inspection on 12/29/11. The area being blanketed was an area used for staging and parking vehicles and was not the area near the gate which has the significant erosion problems. Further blanketing was to be employed at the area near the gate for temporary stabilization until the area can be corrected in the Spring. |
2031097 | Primary Facility | 12/29/2011 | Complaint Inspection | No Violations Noted | A reading of 4 psi after 20 minutes on the 5 x 9 annulus. The well was shut-in for 24 hour monitoring. |
2031102 | Primary Facility | 12/30/2011 | Follow-up Inspection | No Violations Noted | A reading of 84 psi on the 5 x 9 annulus and 3.5 on the 9 x 13 after 24 hour shut-in. |
2031572 | Primary Facility | 01/05/2012 | Administrative/File Review | No Violations Noted | Reviewed E & S Inspection Reports for 10/25 thru 11/14/2011. Reports adequately meet requirements of permit conditions. |
2031935 | Primary Facility | 12/29/2011 | Complaint Inspection | No Violations Noted | DEP Reps - Ryan Klemish, Matt Shope, (Eric Rooney arrived late) met with Chief reps. Rich Adams, Ralph Larsen, and Jon Hafer.Arrived at 10:35 AM. There are 2 annulus' - not shut in. Installed 100 psi pressure guages. After 20 min., the 5 1/2" x 9 5/8" has 3 psi and the 9 5/8" x 13 3/8"? has 0 psi. After 1 hr 17 min, the 5 1/2" x 9 5/8" has 10 psi and ?9 5/8" x 13 3/8"? has o psi. Chief took an isotopic sample. |
2035641 | Primary Facility | 01/20/2012 | Follow-up Inspection | No Violations Noted | |
2036680 | Primary Facility | 01/24/2012 | Administrative/File Review | No Violations Noted | Response to NOV for Inspection ID: 2030254 |
2109049 | Primary Facility | 10/16/2012 | Follow-up Inspection | No Violations Noted | Producing well. No barriers around well head. |
2181691 | Primary Facility | 07/09/2013 | Routine/Complete Inspection | No Violations Noted | |
2505878 | Primary Facility | 2016-07-27 | Routine/Complete Inspection | No Violations Noted | |
2546002 | Primary Facility | 2016-12-19 | Routine/Complete Inspection | No Violations Noted | |
2713312 | Primary Facility | 2018-03-28 | Routine/Complete Inspection | No Violations Noted | Arrived at site at: 08:30. Weather: Overcast, cold ~ 35 degs. Onsite to perform routine inspections of wells on pad. A total of (9) wells were present on pad. All (9) wells were in production at time of inspection. All wells Prod. tree top press. "PTTP", Prod. line press. "PLP" and Prod. casing press. "PCP" were being monitored by wireless data sending units and/or analog gauges. (See individual well pressures and observations listed below.)
- All wells had (2) annular vents present labeled (13 3/8"x 9 5/8") and (9 5/8"x 5 1/2"). All annular vents were open and venting to (3) poly vent tanks "VTs" via shared 2" vent lines. I labeled the VTs with a black magic marker at time of inspection. (#1 VT shares the 2H, 5H, 3H & N1H annular vents. #2 VT shares the N4H, N2H & N3H annular vents. #3 VT shares the 1H & 4H annular vents.) I performed gas checks at VT lid openings using a Altair 5X gas meter calibrated on 3/5/18. Gas checks showed: VT #1 = 48% LEL, 2% CH4; VT #2 = 10% LEL, 0% CH4; VT #3 = 40% LEL, 2% CH4. |
2743686 | Primary Facility | 2018-06-12 | Routine/Complete Inspection | No Violations Noted | "Pump-down" operations were being conducted by Halliburton Oilfield Services on the 1H well. There were no violations noted. If you have any questions, please contact me. |
2804612 | Primary Facility | 2018-11-14 | Routine/Complete Inspection | No Violations Noted | Chief Oil & Gas submitted a Notice of Termination (NOT) for the Garrison pad covered under ESX29-131-17-0003. The NOT was received by the Department on 9/27/18. Arrived onsite for at 10:35; the weather was ~30°F and calm. Several frozen puddles were on the pad surface.
There were 9 properly tagged Marcellus wells staged for production. Most of the well cellars were filled with water; no bubbling was observed. There were 9 GPUs and 1 compressor onsite and in secondary containment. There was approx. 6 to 12 inches of mostly frozen water in the produced water tank secondary containment. Secondary containment also remained around the wells. I contacted Chris Vassallo via email and was informed on 11/16/18 that the containment is there due to scheduled maintenance on one of the wells. The site was well vegetated and appeared stable. All PCSM had been constructed and no temporary E&S BMPs remained. It is recommended that secondary containment around the produced water tanks be monitored and the water removed a |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1956723 | 606430 | 03/11/2011 | 03/14/2011 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1956723 | 606431 | 03/11/2011 | 03/14/2011 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
1956723 | 606442 | 03/11/2011 | 03/14/2011 | 102.4INADPLN - E&S Plan not adequate | Administrative | |
1970791 | 610311 | 05/05/2011 | 06/01/2011 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1970791 | 610312 | 05/05/2011 | 06/01/2011 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
1975452 | 611872 | 05/22/2011 | 06/13/2011 | 78.66A - Failure to report release of substance threatening or causing pollution | Administrative | |
1975452 | 612403 | 05/22/2011 | 06/13/2011 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety | |
2030254 | 628115 | 12/27/2011 | 01/20/2012 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Erosion caused by vehicular traffic near gate to pad. Area was noted in an inspection on 7/7/11 and was not addressed. Area is noted in the operator's E & S Inspection Reports as "unsatisfactory". |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
628115 | 278937 | NOV - Notice of Violation |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 08/07/2011 | 08/07/2011 | 7858.00 | 1,020,138.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Super Scale Control TSC | Superior Well Services | Scale Inhibitor | 1,2,4-Butanetricarboxylic acid, 2-phosphono- | 37971-36-1 | |||
Anionic Copolymer | ||||||||
1,2-Propylene glycol | 57-55-6 | 0.04 | ||||||
Anionic Polymer | ||||||||
Sand (Proppant) | Superior Well Services | Propping Agent | ||||||
Quartz | 14808-60-7 | 99.90 | 10.38 | |||||
Water | Base Fluid | Water | 100.00 | 89.37 | ||||
KR-153SL | Superior Well Services | Biocide | ||||||
Polyethylene glycol | 25322-68-3 | 50.00 | ||||||
Diethylene glycol | 111-46-6 | |||||||
Ethylene glycol | 107-21-1 | 1.00 | ||||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.02 | |||||
WFR-3B | Superior Well Services | Friction Reducer | ||||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.15 | ||||||
Ethoxylated C12-16 alcohols | 68551-12-2 | 4.00 | ||||||
Stoddard solvent | 8052-41-3 | 10.00 | ||||||
1,2-Propylene glycol | 57-55-6 | 25.00 | ||||||
FE OXCLEAR | Superior Well Services | Oxygen Scavenger | Ammonium bisulfite | 10192-30-0 | 0.01 | |||
For data sources see[7]