37-131-20147

Well Details

Well ID: 37-131-20147
Loading map...
Country: United States
State: Pennsylvania
County: Wyoming
Municipality: Lemon Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 145704
Farm/Lease Name: GARRISON UNIT 1H
License Status:
Spud Date:
Permit Date: 2011-03-25
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.625047
Longitude: -75.937856

For data sources see[1][2][3]

Well History

Date Event
2011-03-25 New Permit Application
2011-04-01 Performed Spud Operation
2011-05-01 Drilling Completion
2011-07-06 Perforation
2011-07-06 Performed Stimulation
2011-08-06 Perforation
2011-08-06 Performed Stimulation
2011-08-10 DEVIATED
2012-06-13 REWORKED
2015-05-01 Perforation
2015-05-01 Performed Stimulation
2015-05-13 Drilling Completion
2016-06-09 REWORKED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-08-07 2011-08-07 7,858 1,020,138

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Super Scale Control TSC Superior Well Services Scale Inhibitor 1,2,4-Butanetricarboxylic acid, 2-phosphono- 37971-36-1
Anionic Copolymer
1,2-Propylene glycol 57-55-6 0.04
Anionic Polymer
Sand (Proppant) Superior Well Services Propping Agent
Quartz 14808-60-7 99.90 10.38
Water Base Fluid Water 100.00 89.37
KR-153SL Superior Well Services Biocide
Polyethylene glycol 25322-68-3 50.00
Diethylene glycol 111-46-6
Ethylene glycol 107-21-1 1.00
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.02
WFR-3B Superior Well Services Friction Reducer
Distillates, petroleum, hydrotreated light 64742-47-8 0.15
Ethoxylated C12-16 alcohols 68551-12-2 4.00
Stoddard solvent 8052-41-3 10.00
1,2-Propylene glycol 57-55-6 25.00
FE OXCLEAR Superior Well Services Oxygen Scavenger Ammonium bisulfite 10192-30-0 0.01

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-08-06 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 2,064,665.00 153 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 3,705,497.00 361 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 746,948.00 218 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 992,329.35 364 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 804,783.09 363 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 487,149.46 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 589,074.21 365 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 375,354.23 355 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHIEF OIL & GAS LLC Drill Cuttings 19.11 Tons LANDFILL 100955
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 7,773.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHIEF OIL & GAS LLC Drilling Fluid Waste 480.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011 CHIEF OIL & GAS LLC Drill Cuttings 976.21 Tons LANDFILL 301626
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 780.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 6,364.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Produced Fluid 930.80 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Produced Fluid 1,418.40 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 2,266.19 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 625.49 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Fracing Fluid Waste 1,260.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 CHIEF OIL & GAS LLC Produced Fluid 482.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 75.03 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Produced Fluid 29.36 Bbl REUSE OTHER THAN ROAD SPREADING
2018 CHIEF OIL & GAS LLC Produced Fluid 83.21 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 60.30 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1956723 Primary Facility 2011-03-11 Routine/Complete Inspection Violation(s) Noted
1958644 Primary Facility 2011-03-14 Follow-up Inspection No Violations Noted
1964809 Primary Facility 2011-04-11 Drilling/Alteration No Violations Noted Ziggenfuss moved in 4/1/2011, drilled in conductor- no cement, then drilled to 517' Rig H&P 285 air drilling depth is 616', not drilling now - rig problems
1964976 Primary Facility 2011-04-11 Routine/Complete Inspection No Violations Noted Will return to investigate standing water in ponds at the entrance to the pad. The water is black and is seperated by culvert. Pond on south side of culvert is draining into ground.
1965272 Primary Facility 2011-04-13 Follow-up Inspection No Violations Noted Collected sample from sediment trap and wetland area outside of pad.
1966404 Primary Facility 2011-04-14 Drilling/Alteration No Violations Noted BOP tested 4/13/2011
1967899 Primary Facility 2011-04-25 Routine/Complete Inspection No Violations Noted
1968294 Primary Facility 2011-04-25 Drilling/Alteration No Violations Noted H&P 285, checked drillers log, at 10072', TD will be 12774'
1969132 Primary Facility 2011-04-26 Routine/Complete Inspection No Violations Noted On site to review a copy of the PPC plan and conduct an inspection of the solids handling area. The PPC plan could not be located at the site. I obtained a copy of the PPC plan at a pre-construction meeting back in Feburary. I informed Rich Adams and Matt Barch of Chief of the revisons of the plan that need to be implemented. There were no violations observed during the inspection.
1969660 Primary Facility 2011-05-02 Drilling/Alteration No Violations Noted well is done - company man is not on site
1970791 Primary Facility 2011-05-05 Complaint Inspection Violation(s) Noted
1970847 Primary Facility 2011-05-05 Drilling/Alteration No Violations Noted done drilling on 4/28/2011 cemented on 4/29/2011
1972748 Primary Facility 2011-05-11 Follow-up Inspection Outstanding Violations - No Viols Req'd
1975452 Primary Facility 2011-05-22 Follow-up Inspection Outstanding Violations - Viols Req'd Results for the Oil & Grease sample collected on 5/5/2011 indicated a positive detection of Oil & Grease in the water (8.1 mg/L).
1976387 Primary Facility 2011-05-26 Routine/Complete Inspection No Violations Noted site & well looks good - very little water in cellar Chief released rig
1977008 Primary Facility 2011-06-01 Follow-up Inspection No Violations Noted Outlet to sediment trap at entrance has been modified. Water had been removed. Outlet is dry and appears to be draining sufficiently.
1979731 Primary Facility 2011-06-13 Follow-up Inspection No Violations Noted
1980320 Primary Facility 2011-06-13 Routine/Complete Inspection No Violations Noted preparing to frac - weel head and lots of frac tanks, site looks good
1985130 Primary Facility 2011-07-01 Drilling/Alteration No Violations Noted IPS - integrated production services trucks on site, no comp. man, fracing
1986266 Primary Facility 2011-07-07 Routine/Complete Inspection No Violations Noted
1994470 Primary Facility 2011-08-09 Drilling/Alteration No Violations Noted Well fraced on Sat and Sun (8/6 & 8/7/2011).
1995320 Primary Facility 2011-08-12 Routine/Complete Inspection No Violations Noted Done flowing back after frac, plastic containment, tanks, and some equip. still on site.
2004561 Primary Facility 2011-09-22 Routine/Complete Inspection No Violations Noted Tanks still on site, as well as a dumpster and some sand.
2030254 Primary Facility 2011-12-27 Routine/Complete Inspection Violation(s) Noted Erosion control blankets were installed during a seperate inspection on 12/29/11. The area being blanketed was an area used for staging and parking vehicles and was not the area near the gate which has the significant erosion problems. Further blanketing was to be employed at the area near the gate for temporary stabilization until the area can be corrected in the Spring.
2031097 Primary Facility 2011-12-29 Complaint Inspection No Violations Noted A reading of 4 psi after 20 minutes on the 5 x 9 annulus. The well was shut-in for 24 hour monitoring.
2031102 Primary Facility 2011-12-30 Follow-up Inspection No Violations Noted A reading of 84 psi on the 5 x 9 annulus and 3.5 on the 9 x 13 after 24 hour shut-in.
2031572 Primary Facility 2012-01-05 Administrative/File Review No Violations Noted Reviewed E & S Inspection Reports for 10/25 thru 11/14/2011. Reports adequately meet requirements of permit conditions.
2031935 Primary Facility 2011-12-29 Complaint Inspection No Violations Noted DEP Reps - Ryan Klemish, Matt Shope, (Eric Rooney arrived late) met with Chief reps. Rich Adams, Ralph Larsen, and Jon Hafer.Arrived at 10:35 AM. There are 2 annulus' - not shut in. Installed 100 psi pressure guages. After 20 min., the 5 1/2" x 9 5/8" has 3 psi and the 9 5/8" x 13 3/8"? has 0 psi. After 1 hr 17 min, the 5 1/2" x 9 5/8" has 10 psi and ?9 5/8" x 13 3/8"? has o psi. Chief took an isotopic sample.
2035641 Primary Facility 2012-01-20 Follow-up Inspection No Violations Noted
2036680 Primary Facility 2012-01-24 Administrative/File Review No Violations Noted Response to NOV for Inspection ID: 2030254
2109049 Primary Facility 2012-10-16 Follow-up Inspection No Violations Noted Producing well. No barriers around well head.
2181691 Primary Facility 2013-07-09 Routine/Complete Inspection No Violations Noted
2505878 Primary Facility 2016-07-27 Routine/Complete Inspection No Violations Noted
2546002 Primary Facility 2016-12-19 Routine/Complete Inspection No Violations Noted
2713312 Primary Facility 2018-03-28 Routine/Complete Inspection No Violations Noted Arrived at site at: 08:30. Weather: Overcast, cold ~ 35 degs. Onsite to perform routine inspections of wells on pad. A total of (9) wells were present on pad. All (9) wells were in production at time of inspection. All wells Prod. tree top press. "PTTP", Prod. line press. "PLP" and Prod. casing press. "PCP" were being monitored by wireless data sending units and/or analog gauges. (See individual well pressures and observations listed below.)

- All wells had (2) annular vents present labeled (13 3/8"x 9 5/8") and (9 5/8"x 5 1/2"). All annular vents were open and venting to (3) poly vent tanks "VTs" via shared 2" vent lines. I labeled the VTs with a black magic marker at time of inspection. (#1 VT shares the 2H, 5H, 3H & N1H annular vents. #2 VT shares the N4H, N2H & N3H annular vents. #3 VT shares the 1H & 4H annular vents.) I performed gas checks at VT lid openings using a Altair 5X gas meter calibrated on 3/5/18. Gas checks showed: VT #1 = 48% LEL, 2% CH4; VT #2 = 10% LEL, 0% CH4; VT #3 = 40% LEL, 2% CH4.

2743686 Primary Facility 2018-06-12 Routine/Complete Inspection No Violations Noted "Pump-down" operations were being conducted by Halliburton Oilfield Services on the 1H well. There were no violations noted. If you have any questions, please contact me.
2804612 Primary Facility 2018-11-14 Routine/Complete Inspection No Violations Noted Chief Oil & Gas submitted a Notice of Termination (NOT) for the Garrison pad covered under ESX29-131-17-0003. The NOT was received by the Department on 9/27/18. Arrived onsite for at 10:35; the weather was ~30°F and calm. Several frozen puddles were on the pad surface.

There were 9 properly tagged Marcellus wells staged for production. Most of the well cellars were filled with water; no bubbling was observed. There were 9 GPUs and 1 compressor onsite and in secondary containment. There was approx. 6 to 12 inches of mostly frozen water in the produced water tank secondary containment. Secondary containment also remained around the wells. I contacted Chris Vassallo via email and was informed on 11/16/18 that the containment is there due to scheduled maintenance on one of the wells.

The site was well vegetated and appeared stable. All PCSM had been constructed and no temporary E&S BMPs remained.

It is recommended that secondary containment around the produced water tanks be monitored and the water removed a

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1956723 606430 03/11/2011 2011-03-11 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1956723 606431 03/11/2011 2011-03-11 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
1956723 606442 03/11/2011 2011-03-11 102.4INADPLN - E&S Plan not adequate Administrative
1970791 610311 05/05/2011 2011-05-05 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1970791 610312 05/05/2011 2011-05-05 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
1975452 611872 05/22/2011 2011-05-22 78.66A - Failure to report release of substance threatening or causing pollution Administrative
1975452 612403 05/22/2011 2011-05-22 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
2030254 628115 12/27/2011 2011-12-27 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety Erosion caused by vehicular traffic near gate to pad. Area was noted in an inspection on 7/7/11 and was not addressed. Area is noted in the operator's E & S Inspection Reports as "unsatisfactory".

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
628115 278937 NOV - Notice of Violation

For data sources see[9]

References