X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-117-20737"

m
 
(16 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 117-20737
+
| Well ID: 37-117-20737
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.645955, -77.327672 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.645956, -77.327672 | width=100% | height=100% }}
 +
|-
 +
| Country: United States
 +
|-
 +
| State: Pennsylvania
 
|-
 
|-
| County: [[Tioga County, Pennsylvania|Tioga]]
+
| County: [[Tioga_County,_Pennsylvania|Tioga]]
 
|-
 
|-
| Municipality: [[Delmar Township, Tioga County, Pennsylvania|Delmar Township]]
+
| Municipality: [[Delmar Township,_Tioga_County,_Pennsylvania|Delmar Township]]
 
|-
 
|-
 
| Operator Name: [[SWEPI LP]]
 
| Operator Name: [[SWEPI LP]]
 +
|-
 +
| Well Pad ID: [[147860]]
 
|-
 
|-
 
| Farm/Lease Name: BROADBENT 466 1V
 
| Farm/Lease Name: BROADBENT 466 1V
 
|-
 
|-
| First Permit Date: 2010-06-10
+
| License Status: INACTIVE
 
|-
 
|-
| Last Permit Date: 2010-06-10
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2010-06-24
+
| Permit Date: 2010-06-10
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: No
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Vertical Well
 
|-
 
|-
| Violations: None
+
| Conservation: No
 
|-
 
|-
| Latitude: 41.645955
+
| Latitude: 41.645956
 
|-
 
|-
 
| Longitude: -77.327672
 
| Longitude: -77.327672
|-
 
 
|}
 
|}
__TOC__
+
For data sources see<ref>{{cite web
== Well Inspection Data ==
+
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Date
!scope="col" | DATE
+
!scope="col" | Event
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
 
|-
 
|-
| 1978604
+
| 2010-06-10
| 2011-06-06
+
| New Permit Application
| No Violations Noted
 
|
 
|  
 
 
|-
 
|-
 +
| 2010-06-24
 +
| Performed Spud Operation
 
|-
 
|-
| 2066999
+
| 2010-07-28
| 2012-05-03
+
| Drilling Completion
| No Violations Noted
 
| The original 117-20737 well location was plugged due to a fish (BHA) stuck in the well.
 
|  
 
 
|-
 
|-
 +
| 2010-09-09
 +
| Perforation
 
|-
 
|-
| 2088257
+
| 2014-05-12
| 2012-07-30
+
| NEWLY DRILLED
| No Violations Noted
 
|
 
|  
 
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|}-->
 +
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2012-2
+
| 2010
| style="text-align:right;" | 0.0
+
| [[EAST RESOURCES MGMT LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2011
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2012
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2014
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-1
+
| 2016
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-2
+
| 2019
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
+
|-
!scope="col" | FACILITY CITY
+
| 2012
!scope="col" | FACILITY STATE
+
| [[SWEPI LP]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 52.38 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2012
 +
| [[SWEPI LP]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 4,226.57 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|  
 
|-
 
|-
| 2012-2
+
| 2012
| FRACING FLUID WASTE
+
| [[SWEPI LP]]
| style="text-align:right;" | 203.33
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 203.33 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR0123
+
| WMGR123
| HYDRO RECOVERY - BLOSSBURG
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
| 2012-2
+
| 1978604
| FRACING FLUID WASTE
+
| Primary Facility
| style="text-align:right;" | 4226.57
+
| 2011-06-06
| Bbl
+
| Routine/Complete Inspection
| REUSE OTHER THAN ROAD SPREADING
+
| No Violations Noted
|  
 
| REUSE FOR HYDRAULIC FRACTURING
 
 
|  
 
|  
 +
|-
 +
| 2066999
 +
| Primary Facility
 +
| 2012-05-03
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The original 117-20737 well location was plugged due to a fish (BHA) stuck in the well.
 +
|-
 +
| 2088257
 +
| Primary Facility
 +
| 2012-07-30
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2423730
 +
| Primary Facility
 +
| 2015-11-05
 +
| Site Restoration
 +
| No Violations Noted
 +
| Restoration inspection. Notice of Termination and Well Site Restoration Reports received 10/29/15. Documents are administratively complete. Interim restoration completed at site. Majority of pad surface decompacted and vegetated. Water storage pad and an upgradient diversion channel removed, graded to original contour and vegetated. Site is permanently stabilized and no temporary E&S controls remain. Recommend approval of Notice of Termination. Well Site Restoration Reports acknowledged 11/10/15. TLT
 +
|-
 +
| 2519013
 +
| Primary Facility
 +
| 2016-09-13
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Inspection of SWEPI’s Broadbent 466 pad in Delmar Twp. Tioga County conducted September 13, 2016 at approximately 12:00 pm. There were (3) wells on the pad at the time of inspection; the 5HB (Inactive Status), the 1V (Inactive Status), and the 1V (Plugged). The plugged 1V and the inactive 1V share the same API permit # (117-20737) which records indicate was due to a plug and skid event. At the time of inspection; the 5HB has a production tree in place, assumed to be completed, shut in w/ (2) master gate valves atop production casing spool w/tubing hanger and wing valves at side outlets. There were no pressure gauges on the well, just a taylor plug valve on one of the production casing’s wing valve for a pressure gauge probe or crystal gauge. There was an ESD valve on the proposed line out to prod. equip. with manual lever (not hooked to gas). The cellar was filled with gravel with (4) vent pipes total plumbed to surface. There were (2) 2” vent pipes assumed to be the backside of production casing. One of the
 
|-
 
|-
| 2012-2
+
| 2586154
| PRODUCED FLUID
+
| Primary Facility
| style="text-align:right;" | 52.38
+
| 2017-04-21
| Bbl
+
| Routine/Complete Inspection
| REUSE OTHER THAN ROAD SPREADING
+
| No Violations Noted
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|  
 
 
|  
 
|  
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]

Latest revision as of 02:19, 16 May 2020

Well Details

Well ID: 37-117-20737
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Delmar Township
Operator Name: SWEPI LP
Well Pad ID: 147860
Farm/Lease Name: BROADBENT 466 1V
License Status: INACTIVE
Spud Date:
Permit Date: 2010-06-10
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.645956
Longitude: -77.327672

For data sources see[1][2][3]

Well History

Date Event
2010-06-10 New Permit Application
2010-06-24 Performed Spud Operation
2010-07-28 Drilling Completion
2010-09-09 Perforation
2014-05-12 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 0.00 0 0.00 0 0.00 0
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0
2019 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SWEPI LP Produced Fluid 52.38 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Fracing Fluid Waste 4,226.57 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SWEPI LP Fracing Fluid Waste 203.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1978604 Primary Facility 2011-06-06 Routine/Complete Inspection No Violations Noted
2066999 Primary Facility 2012-05-03 Routine/Complete Inspection No Violations Noted The original 117-20737 well location was plugged due to a fish (BHA) stuck in the well.
2088257 Primary Facility 2012-07-30 Routine/Partial Inspection No Violations Noted
2423730 Primary Facility 2015-11-05 Site Restoration No Violations Noted Restoration inspection. Notice of Termination and Well Site Restoration Reports received 10/29/15. Documents are administratively complete. Interim restoration completed at site. Majority of pad surface decompacted and vegetated. Water storage pad and an upgradient diversion channel removed, graded to original contour and vegetated. Site is permanently stabilized and no temporary E&S controls remain. Recommend approval of Notice of Termination. Well Site Restoration Reports acknowledged 11/10/15. TLT
2519013 Primary Facility 2016-09-13 Routine/Complete Inspection No Violations Noted Inspection of SWEPI’s Broadbent 466 pad in Delmar Twp. Tioga County conducted September 13, 2016 at approximately 12:00 pm. There were (3) wells on the pad at the time of inspection; the 5HB (Inactive Status), the 1V (Inactive Status), and the 1V (Plugged). The plugged 1V and the inactive 1V share the same API permit # (117-20737) which records indicate was due to a plug and skid event. At the time of inspection; the 5HB has a production tree in place, assumed to be completed, shut in w/ (2) master gate valves atop production casing spool w/tubing hanger and wing valves at side outlets. There were no pressure gauges on the well, just a taylor plug valve on one of the production casing’s wing valve for a pressure gauge probe or crystal gauge. There was an ESD valve on the proposed line out to prod. equip. with manual lever (not hooked to gas). The cellar was filled with gravel with (4) vent pipes total plumbed to surface. There were (2) 2” vent pipes assumed to be the backside of production casing. One of the
2586154 Primary Facility 2017-04-21 Routine/Complete Inspection No Violations Noted

For data sources see[7]

References