X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-117-20737"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-117-20737
 
| Well ID: 37-117-20737
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.645956, -77.327672 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.645956, -77.327672 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Regulatory Inactive Status
 
| License Status: Regulatory Inactive Status
 
|-
 
|-
| Spud Date: 06/24/2010
+
| Spud Date: 2010-06-24
 
|-
 
|-
| Permit Date: 6/10/2010
+
| Permit Date: 2010-06-10
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|}-->
 +
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 156: Line 181:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 203.33 Bbl
 
| style="text-align: right;" | 203.33 Bbl
Line 162: Line 187:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 4,226.57 Bbl
 
| style="text-align: right;" | 4,226.57 Bbl
Line 168: Line 193:
 
|  
 
|  
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 52.38 Bbl
 
| style="text-align: right;" | 52.38 Bbl
Line 193: Line 218:
 
| 1978604
 
| 1978604
 
| Primary Facility
 
| Primary Facility
| 06/06/2011
+
| 2011-06-06
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 200: Line 225:
 
| 2066999
 
| 2066999
 
| Primary Facility
 
| Primary Facility
| 05/03/2012
+
| 2012-05-03
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 207: Line 232:
 
| 2088257
 
| 2088257
 
| Primary Facility
 
| Primary Facility
| 07/30/2012
+
| 2012-07-30
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 214: Line 239:
 
| 2423730
 
| 2423730
 
| Primary Facility
 
| Primary Facility
| 11/05/2015
+
| 2015-11-05
 
| Site Restoration
 
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
Line 263: Line 288:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
<!--== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|}-->
 
<!--==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|}-->
 
 
 
==References==
 
==References==
 
<references/>
 
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Pennsylvania Wells]]
 
[[Category:Pennsylvania Wells]]

Revision as of 14:19, 2 August 2019

Well Details

Well ID: 37-117-20737
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Delmar Township
Operator Name: SWEPI LP
Well Pad ID: 147860
Farm/Lease Name: BROADBENT 466 1V
License Status: Regulatory Inactive Status
Spud Date: 2010-06-24
Permit Date: 2010-06-10
Unconventional Well: Y
Configuration: Vertical Well
Latitude: 41.645956
Longitude: -77.327672

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 0.00 0 0.00 0 0.00 0
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0
2017 SWEPI LP 0.00 0 0.00 0 0.00 0
2019 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S02 Fracing Fluid Waste (in Barrels) 203.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-S02 Fracing Fluid Waste (in Barrels) 4,226.57 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Produced Fluid (in Barrels) 52.38 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1978604 Primary Facility 2011-06-06 Routine/Complete Inspection No Violations Noted
2066999 Primary Facility 2012-05-03 Routine/Complete Inspection No Violations Noted The original 117-20737 well location was plugged due to a fish (BHA) stuck in the well.
2088257 Primary Facility 2012-07-30 Routine/Partial Inspection No Violations Noted
2423730 Primary Facility 2015-11-05 Site Restoration No Violations Noted Restoration inspection. Notice of Termination and Well Site Restoration Reports received 10/29/15. Documents are administratively complete. Interim restoration completed at site. Majority of pad surface decompacted and vegetated. Water storage pad and an upgradient diversion channel removed, graded to original contour and vegetated. Site is permanently stabilized and no temporary E&S controls remain. Recommend approval of Notice of Termination. Well Site Restoration Reports acknowledged 11/10/15. TLT
2519013 Primary Facility 2016-09-13 Routine/Complete Inspection No Violations Noted Inspection of SWEPI’s Broadbent 466 pad in Delmar Twp. Tioga County conducted September 13, 2016 at approximately 12:00 pm. There were (3) wells on the pad at the time of inspection; the 5HB (Inactive Status), the 1V (Inactive Status), and the 1V (Plugged). The plugged 1V and the inactive 1V share the same API permit # (117-20737) which records indicate was due to a plug and skid event. At the time of inspection; the 5HB has a production tree in place, assumed to be completed, shut in w/ (2) master gate valves atop production casing spool w/tubing hanger and wing valves at side outlets. There were no pressure gauges on the well, just a taylor plug valve on one of the production casing’s wing valve for a pressure gauge probe or crystal gauge. There was an ESD valve on the proposed line out to prod. equip. with manual lever (not hooked to gas). The cellar was filled with gravel with (4) vent pipes total plumbed to surface. There were (2) 2” vent pipes assumed to be the backside of production casing. One of the
2586154 Primary Facility 2017-04-21 Routine/Complete Inspection No Violations Noted

For data sources see[6]

References