X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-115-21628"

m
m
 
(3 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-115-21628
 
| Well ID: 37-115-21628
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.958786, -76.040291 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.958786, -76.040292 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Susquehanna County, Pennsylvania|Susquehanna]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Choconut Township, Susquehanna County, Pennsylvania|Choconut Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[TALISMAN ENERGY USA INC]]
+
| County: [[Susquehanna_County,_Pennsylvania|Susquehanna]]
 
|-
 
|-
| Well Pad ID: [[150803|150803]]
+
| Municipality: [[Choconut Township,_Susquehanna_County,_Pennsylvania|Choconut Township]]
 +
|-
 +
| Operator Name: [[REPSOL OIL & GAS USA LLC]]
 +
|-
 +
| Well Pad ID: [[150803]]
 
|-
 
|-
 
| Farm/Lease Name: STICKNEY 07 087 02 A 2H
 
| Farm/Lease Name: STICKNEY 07 087 02 A 2H
 
|-
 
|-
| First Permit Date: 2014-01-16
+
| License Status:  
 
|-
 
|-
| Last Permit Date: 2014-01-16
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2014-04-15
+
| Permit Date: 2014-01-16
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Well Status: ACTIVE
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: 0
+
| Conservation: No
 
|-
 
|-
 
| Latitude: 41.958786
 
| Latitude: 41.958786
 
|-
 
|-
| Longitude: -76.040291
+
| Longitude: -76.040292
|-
 
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Date
!scope="col" | GAS QUANTITY
+
!scope="col" | Event
!scope="col" | GAS PRODUCTION DAYS
 
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
|-
 
| 2014-1
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
 
|-
 
|-
| 2014-2
+
| 2014-01-16
| style="text-align:right;" | 0.0
+
| New Permit Application
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|-
+
| 2014-04-15
| 2015-02
+
| Performed Spud Operation
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-01
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2015-03
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2020-02-27
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | accessdate = 2020-02-27 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
== Fracking Activities ==
== Waste Data ==
+
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Job Number
!scope="col" | TYPE
+
!scope="col" | Job Start Date
!scope="col" | QUANTITY
+
!scope="col" | Job End Date
!scope="col" | UNITS
+
!scope="col" | True Vertical Depth (ft)
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Total Water Volume (gal)
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Total Non-Water Volume (gal)
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2014-1
+
| 1
| DRILL CUTTINGS
+
| 2014-08-18
| style="text-align:right;" | 949.09
+
| 2014-08-18
| Tons
+
| style="text-align: right;" | 5,973
| LANDFILL
+
| style="text-align: right;" | 5,469,620
| 8-0728-0004/013
+
| style="text-align: right;" | 34,000
| CHEMUNG COUNTY LANDFILL
 
| LOWMAN
 
| NY
 
 
|-
 
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 2014-2
+
|- valign="top"
| FLOWBACK FRACTURING SAND
+
| rowspan="31"| 1
| style="text-align:right;" | 36.72
+
| rowspan="1"| White 40/70
| Tons
+
| rowspan="1"| Trican
| LANDFILL
+
| rowspan="1"| Proppant
| 100361
+
| Crystalline silica: Quartz (SiO2)
| MCKEAN COUNTY LANDFILL
+
| 14808-60-7
| KANE
+
| style="text-align: right;" | 100
| PA
+
| style="text-align: right;" | 7.92507
 +
| style="text-align: right;" | 4,544,440.0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| AI-7NR (Acid Inhibitor)
 +
| rowspan="1"| Trican
 +
| rowspan="1"| Acid Inhibitor
 +
| Prop-2-yn-1-ol
 +
| 107-19-7
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00001200
 +
| style="text-align: right;" | 6.67632
 
|-
 
|-
| 2014-2
+
|- valign="top"
| FRACING FLUID WASTE
+
| rowspan="1"| 100 Mesh, Bulk (over 20K lbs)*
| style="text-align:right;" | 1.0
+
| rowspan="1"| Trican
| Bbl
+
| rowspan="1"| Proppant
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| Crystalline silica: Quartz (SiO2)
| WMGR123NC010
+
| 14808-60-7
| HYDRO RECOVERY LP ANTRIM FACILITY
+
| style="text-align: right;" | 100
| WELLSBORO
+
| style="text-align: right;" | 7.03571
| PA
+
| style="text-align: right;" | 4,034,460.0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"| Customer
 +
| rowspan="1"| Carrier
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 79.6027
 +
| style="text-align: right;" | 45,646,200.0
 
|-
 
|-
| 2014-2
+
|- valign="top"
| FRACING FLUID WASTE
+
| rowspan="2"| FEAC-20 (Iron Control)
| style="text-align:right;" | 21.0
+
| rowspan="2"| Trican
| Bbl
+
| rowspan="2"| Iron Control
| REUSE OTHER THAN ROAD SPREADING
+
| Citric acid
|  
+
| 77-92-9
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
| style="text-align: right;" | 30
|
+
| style="text-align: right;" | 0.000824
|  
+
| style="text-align: right;" | 472.684
 
|-
 
|-
|}
+
| Acetic acid
For data sources see<ref>{{cite web
+
| 64-19-7
| title = Oil and Gas Historical Waste Report
+
| style="text-align: right;" | 45
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| style="text-align: right;" | 0.001236
| date = 2015-05-26
+
| style="text-align: right;" | 709.026
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
 
| accessdate = 2015-05-26 }}</ref>
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | INSPECTION ID
 
!scope="col" | DATE
 
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| 2252903
+
|- valign="top"
| 2014-03-12
+
| rowspan="4"| FR-8
| No Violations Noted
+
| rowspan="4"| Trican
|  
+
| rowspan="4"| Friction Reducer
|  
+
| Ammonium Chloride
|  
+
| 12125-02-9
|  
+
| style="text-align: right;" | 1.5
 +
| style="text-align: right;" | 0.001073
 +
| style="text-align: right;" | 615.07
 
|-
 
|-
 +
| Petroleum distillates, dewaxed heavy paraffinic
 +
| 64742-65-0
 +
| style="text-align: right;" | 8
 +
| style="text-align: right;" | 0.005721
 +
| style="text-align: right;" | 3280.37
 
|-
 
|-
| 2309427
+
| Petroleum distillates, hydrotreated heavy paraffinic
| 2014-09-15
+
| 64742-54-7
| No Violations Noted
+
| style="text-align: right;" | 8
| Arrived at the site at 12:50 to conduct an inspection related to an estimated (300-400) barrel flowback fluid spill which occurred on 8/9/14. Flowback procedures and natural gas flaring were in progress as the Department arrived to the location. An excavator was in the process of removing the frac tank battery containment liner from the pad surface. The liner was being transferred to a container in preparation for disposal.The primary purpose of the inspection was to evaluate the pad surface beneath the frac tank battery containment due to the spill that occurred on 8/9/14. The pad surface was evaluated in the general vicinity where the spill occurred for evidence of contamination in the in the event of potential compromised liner integrity as the flowback fluid was spilled to containment. Based on visual observations and site evaluations
+
| style="text-align: right;" | 0.005721
|  
+
| style="text-align: right;" | 3280.37
|
 
|  
 
 
|-
 
|-
|}
+
| Mineral oil/ light hydrotreated pet. distillate
For data sources see<ref>{{cite web
+
| 64742-47-8
| title = Oil and Gas Historical Inspection Report
+
| style="text-align: right;" | 28
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| style="text-align: right;" | 0.020022
| date = 2015-05-26
+
| style="text-align: right;" | 11481.3
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
 
| accessdate = 2015-05-27 }}</ref>
 
[[Category:Has Chemical Data]]
 
==Chemical Data==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | HF Fluid Concentration
 
!scope="col" | Ingredient
 
!scope="col" | Additive Concentration
 
!scope="col" | Trade Name
 
!scope="col" | Purpose
 
!scope="col" | CAS number
 
!scope="col" | Supplier
 
|-
 
| 7.03572
 
| Crystalline silica: Quartz (SiO2)
 
| 100.0
 
| 100 Mesh
 
| Trican
 
| 14808-60-7
 
|  Bulk (over 20K lbs)*
 
 
|-
 
|-
|-
+
|- valign="top"
| 0.014263
+
| rowspan="1"| 3 1/2% HCL
 +
| rowspan="1"| Trican
 +
| rowspan="1"| Carrier
 
| Hydrochloric acid
 
| Hydrochloric acid
| 3.5
 
| 3 1/2% HCL
 
| Carrier
 
 
| 7647-01-0
 
| 7647-01-0
| Trican
+
| style="text-align: right;" | 3.5
 +
| style="text-align: right;" | 0.014263
 +
| style="text-align: right;" | 8178.5
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="4"| AQUCAR DB 5 (Water Treatment Microbiocide)
 +
| rowspan="4"| Trican
 +
| rowspan="4"| Biocide
 +
| Sodium Bromide
 +
| 7647-15-6
 +
| style="text-align: right;" | 1.5
 +
| style="text-align: right;" | 0.000394
 +
| style="text-align: right;" | 226.135
 
|-
 
|-
| 1.2e-05
+
| Polyethylene glycol
| Prop-2-yn-1-ol
+
| 25322-68-3
| 1.0
+
| style="text-align: right;" | 65.2
| AI-7NR (Acid Inhibitor)
+
| style="text-align: right;" | 0.017141
| Acid Inhibitor
+
| style="text-align: right;" | 9829.33
| 107-19-7
 
| Trican
 
 
|-
 
|-
 +
| Dibromoacetonitrile
 +
| 3252-43-5
 +
| style="text-align: right;" | 0.5
 +
| style="text-align: right;" | 0.000131
 +
| style="text-align: right;" | 75.3783
 
|-
 
|-
| 4.81129
+
| 2,2-dibromo-3-nitrilopropionamide
| Crystalline silica: Quartz (SiO2)
+
| 10222-01-2
| 100.0
+
| style="text-align: right;" | 5
| White 30/50
+
| style="text-align: right;" | 0.001315
| Proppant
+
| style="text-align: right;" | 753.783
| 14808-60-7
 
| Trican
 
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="12"|
 +
| rowspan="12"|
 +
| rowspan="12"| Other Chemicals
 +
| Acrylamide
 +
| 79-06-1
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0
 
| Isopropanol
 
| 0.0
 
|
 
| Other Chemicals
 
| 67-63-0
 
|
 
|-
 
|-
 
| 0.0
 
 
| Trade Secret
 
| Trade Secret
| 0.0
 
|
 
| Other Chemicals
 
 
| Proprietary
 
| Proprietary
|  
+
| style="text-align: right;" | 0
|-
+
| style="text-align: right;" | 0
|-
+
| style="text-align: right;" | 0
| 0.0
 
| Ammonium Acrylate
 
| 0.0
 
|  
 
| Other Chemicals
 
| 10604-69-0
 
|
 
 
|-
 
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0
 
 
| Polyethylene glycol monooleate
 
| Polyethylene glycol monooleate
| 0.0
 
|
 
| Other Chemicals
 
 
| 9004-96-0
 
| 9004-96-0
|  
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Sorbitol Tetraoleate
 +
| 61723-83-9
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0
 
 
| Alkyloxypolyethylene oxyethanol
 
| Alkyloxypolyethylene oxyethanol
| 0.0
 
|
 
| Other Chemicals
 
 
| 84133-50-6
 
| 84133-50-6
|  
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| Ammonium Acrylate
 +
| 10604-69-0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 0.0
 
 
| Acrylamide P/W acrylic acid ammonium salt
 
| Acrylamide P/W acrylic acid ammonium salt
| 0.0
 
|
 
| Other Chemicals
 
 
| 26100-47-0
 
| 26100-47-0
|  
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
 
| 0.0
 
 
| Sorbitan monooleate
 
| Sorbitan monooleate
| 0.0
 
|
 
| Other Chemicals
 
 
| 1338-43-8
 
| 1338-43-8
|  
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
| Nonionic Surfactant
 +
| Proprietary
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
| Anionic polyacrylamide copolymer
 +
| Proprietary
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| LSI-21 (Scale Inhibitor)
 +
| rowspan="2"| Trican
 +
| rowspan="2"| Scale Inhibitor
 +
| Sodium Salt of Phosphate Ester
 +
| 68131-72-6
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.003821
 +
| style="text-align: right;" | 2191.34
 +
|-
 +
| Acrylic Polymer
 +
| 28205-96-1
 +
| style="text-align: right;" | 15
 +
| style="text-align: right;" | 0.003821
 +
| style="text-align: right;" | 2191.34
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| 7 1/2% HCL
 +
| rowspan="1"| Trican
 +
| rowspan="1"| Carrier
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 7.5
 +
| style="text-align: right;" | 0.006792
 +
| style="text-align: right;" | 3894.76
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| White 30/50
 +
| rowspan="1"| Trican
 +
| rowspan="1"| Proppant
 +
| Crystalline silica: Quartz (SiO2)
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 4.81129
 +
| style="text-align: right;" | 2,758,920.0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2014
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2015
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 260,140.00
 +
| style="text-align: right;" | 54
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2016
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 896,843.70
 +
| style="text-align: right;" | 298
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2017
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 689,579.70
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2018
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 467,004.70
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2019
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| style="text-align: right;" | 306,542.90
 +
| style="text-align: right;" | 358
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 
|-
 
|-
| 0.0
+
| 2014
| Sorbitol Tetraoleate
+
| [[REPSOL OIL & GAS USA LLC]]
| 0.0
+
| Fracing Fluid Waste
|  
+
| style="text-align: right;" | 21,497.00 Bbl
| Other Chemicals
+
| REUSE OTHER THAN ROAD SPREADING
| 61723-83-9
 
 
|  
 
|  
 
|-
 
|-
 +
| 2014
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 1,746.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 
|-
 
|-
| 0.0
+
| 2014
| Acrylamide
+
| [[REPSOL OIL & GAS USA LLC]]
| 0.0
+
| Fracturing Fluid Waste
|  
+
| style="text-align: right;" | 36.72 Tons
| Other Chemicals
+
| LANDFILL
| 79-06-1
+
| 100361
|  
 
 
|-
 
|-
 +
| 2014
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 949.09 Tons
 +
| LANDFILL
 +
| 8-0728-0004/013
 
|-
 
|-
| 0.0
+
| 2015
| Water
+
| [[REPSOL OIL & GAS USA LLC]]
| 0.0
+
| Produced Fluid
|  
+
| style="text-align: right;" | 925.00 Bbl
| Other Chemicals
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| 7732-18-5
+
| WMGR123
|  
 
 
|-
 
|-
 +
| 2015
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,000.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 
|-
 
|-
| 0.0
+
| 2016
| Nonionic Surfactant
+
| [[REPSOL OIL & GAS USA LLC]]
| 0.0
+
| Produced Fluid
|  
+
| style="text-align: right;" | 7,165.00 Bbl
| Other Chemicals
+
| REUSE OTHER THAN ROAD SPREADING
| Proprietary
 
 
|  
 
|  
 
|-
 
|-
 +
| 2016
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 705.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 +
|-
 +
| 2016
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,234.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 8.0
+
| 2016
| Petroleum distillates
+
| [[REPSOL OIL & GAS USA LLC]]
| 64742.0
+
| Produced Fluid
| FR-8
+
| style="text-align: right;" | 300.00 Bbl
| Friction Reducer
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| dewaxed heavy paraf
+
| WMGR123
| Trican
 
 
|-
 
|-
 +
| 2017
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 240.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 0.020022
+
| 2017
| Mineral oil/ light hydrotreated pet. distillate
+
| [[REPSOL OIL & GAS USA LLC]]
| 28.0
+
| Produced Fluid
| FR-8
+
| style="text-align: right;" | 609.00 Bbl
| Friction Reducer
+
| RESIDUAL WASTE PROCESSING FACILITY
| 64742-47-8
+
| WMGR123NC010
| Trican
 
 
|-
 
|-
 +
| 2017
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 3,952.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 8.0
+
| 2018
| Petroleum distillates
+
| [[REPSOL OIL & GAS USA LLC]]
| 64742.0
+
| Produced Fluid
| FR-8
+
| style="text-align: right;" | 500.00 Bbl
| Friction Reducer
+
| RESIDUAL WASTE PROCESSING FACILITY
| hydrotreated heavy
+
| WMGR123NC010
| Trican
 
 
|-
 
|-
 +
| 2018
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 200.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123
 
|-
 
|-
| 0.001073
+
| 2018
| Ammonium Chloride
+
| [[REPSOL OIL & GAS USA LLC]]
| 1.5
+
| Produced Fluid
| FR-8
+
| style="text-align: right;" | 2,412.00 Bbl
| Friction Reducer
+
| REUSE (AT WELL PAD)
| 12125-02-9
+
|  
| Trican
 
 
|-
 
|-
 +
| 2019
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 106.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 
|-
 
|-
| 0.001236
+
| 2019
| Acetic acid
+
| [[REPSOL OIL & GAS USA LLC]]
| 45.0
+
| Produced Fluid
| FEAC-20 (Iron Control)
+
| style="text-align: right;" | 1,300.00 Bbl
| Iron Control
+
| REUSE (AT WELL PAD)
| 64-19-7
+
|  
| Trican
 
 
|-
 
|-
 +
| 2019
 +
| [[REPSOL OIL & GAS USA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 100.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC018
 
|-
 
|-
| 0.006792
+
| 2019
| Hydrochloric acid
+
| [[REPSOL OIL & GAS USA LLC]]
| 7.5
+
| Other Oil & Gas Wastes
| 7 1/2% HCL
+
| style="text-align: right;" | 60.00 Bbl
| Carrier
+
| REUSE (AT WELL PAD)
| 7647-01-0
+
|  
| Trican
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
| 0.003821
+
| 2252903
| Sodium Salt of Phosphate Ester
+
| Primary Facility
| 15.0
+
| 2014-03-12
| LSI-21 (Scale Inhibitor)
+
| Preoperation Inspection
| Scale Inhibitor
+
| No Violations Noted
| 68131-72-6
+
|  
| Trican
 
 
|-
 
|-
 +
| 2264852
 +
| Primary Facility
 +
| 2014-04-04
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| Conductor set
 
|-
 
|-
| 0.003821
+
| 2266737
| Acrylic Polymer
+
| Primary Facility
| 15.0
+
| 2014-04-18
| LSI-21 (Scale Inhibitor)
+
| Drilling/Alteration
| Scale Inhibitor
+
| No Violations Noted
| 28205-96-1
+
| Conductor set
| Trican
 
 
|-
 
|-
 +
| 2278099
 +
| Primary Facility
 +
| 2014-05-31
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 79.6027
+
| 2291279
| Water
+
| Primary Facility
| 100.0
+
| 2014-07-29
| Water
+
| Routine/Complete Inspection
| Carrier
+
| No Violations Noted
| 7732-18-5
+
|  
| Customer
 
 
|-
 
|-
 +
| 2309427
 +
| Primary Facility
 +
| 2014-09-15
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 +
| Arrived at the site at 12:50 to conduct an inspection related to an estimated (300-400) barrel flowback fluid spill which occurred on 8/9/14.  Flowback procedures and natural gas flaring were in progress as the Department arrived to the location.  An excavator was in the process of removing the frac tank battery containment liner from the pad surface.  The liner was being transferred to a container in preparation for disposal.  The primary purpose of the inspection was to evaluate the pad surface beneath the frac tank battery containment due to the spill that occurred on 8/9/14.  The pad surface was evaluated in the general vicinity where the spill occurred for evidence of contamination in the in the event of potential compromised liner integrity as the flowback fluid was spilled to containment.  Based on visual observations and site evaluations, there is no evidence that the spill on 8/9/14 impacted the surface of the ground on and off the well pad.
 
|-
 
|-
| 0.017141
+
| 2386093
| Polyethylene glycol
+
| Primary Facility
| 65.2
+
| 2015-07-08
| AQUCAR DB 5 (Water Treatment Microbiocide)
+
| Routine/Complete Inspection
| Biocide
+
| No Violations Noted
| 25322-68-3
+
|  
| Trican
 
 
|-
 
|-
 +
| 2440317
 +
| Primary Facility
 +
| 2016-01-13
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 +
| The area around the pad was stable and appeared to have all BMPs in place.  There was vegetation visible on site through the snow cover. 
 +
 +
There are no violations.
 +
 +
If there are any questions, please feel free to call me at (570) 346-5539.
 
|-
 
|-
| 0.000394
+
| 2498588
| Sodium Bromide
+
| Primary Facility
| 1.5
+
| 2016-07-01
| AQUCAR DB 5 (Water Treatment Microbiocide)
+
| Routine/Complete Inspection
| Biocide
+
| No Violations Noted
| 7647-15-6
+
| At time of inspection, arrived on site at 12:35p.m., the cellar was full of water with no bubbling noticed, the (20x13) vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) vent pipe was open and venting into the atmosphere with no gas detected. There was 913psi on the production casing and 455psi on the production tubing. I took a walk around the location and everything looked OK.
| Trican
+
I left the site at 12:50p.m.
 
|-
 
|-
 +
| 2588478
 +
| Primary Facility
 +
| 2017-04-27
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|  At time of inspection, arrived on site at 10:50a.m.
 +
The cellar was full of water with no bubbling noticed.
 +
The (20x13) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) annulus vent pipe was open and venting into the atmosphere with no gas detected.
 +
There was 550psi on the production casing and 367psi on the production line.
 +
I took a walk around the location and there were no obvious concerns noticed.     
 +
I left the site at 11:20a.m.
 
|-
 
|-
| 0.000131
+
| 2697770
| Dibromoacetonitrile
+
| Primary Facility
| 0.5
+
| 2018-02-15
| AQUCAR DB 5 (Water Treatment Microbiocide)
+
| Routine/Complete Inspection
| Biocide
+
| No Violations Noted
| 3252-43-5
+
| At time of inspection.
| Trican
+
The well was in production.
 +
The cellar was full of water and there was no bubbling noticed.
 +
I took a walk around the location and there were no obvious concerns noticed.
 +
There were no violations noted.
 
|-
 
|-
 +
| 2793493
 +
| Primary Facility
 +
| 2018-10-22
 +
| Site Restoration
 +
| No Violations Noted
 +
| I performed a RTNC inspection for for the Stickney well site.  The site had its last company E&S inspection on 10/13/2018. 
 +
    The pad surface area was 180196 square feet.
 +
    The weather was overcast and 40 degrees.  The pad surface and access road were dry.
 +
    The access road was solid and firm, as was the pad surface.  The area was quite rocky.
 +
    The cut and fill slopes were well vegetated, wherever possible.  The rocky nature of the area precludes growth where there is no soil, however wherever there was soil present, there was perennial growth exceeding 70%, as required by the Department.
 +
    The area was stable and solid and the well was properly labeled.  The PCSM infiltration basins were installed and vegetation was adequate on the available soil. 
 +
    There were no violations noted.
 +
      The well was properly labeled
 
|-
 
|-
| 5.0
+
| 2794697
| 2
+
| Primary Facility
| 10222.0
+
| 2018-10-25
| AQUCAR DB 5 (Water Treatment Microbiocide)
+
| Routine/Complete Inspection
| Biocide
+
| No Violations Noted
| 2-dibromo-3-nitrilop
+
| At time of inspection.
| Trican
+
The well was in production.
 +
The cellar was full of water and there was no bubbling noticed.
 +
There was a methanol tank and pump (see photo) in containment and the containment appeared to be in good condition.
 +
I took a walk around the location and there were no obvious concerns noticed.
 +
There were no violations noted.
 
|-
 
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 
|-
 
|-
| 7.92507
+
|}-->
| Crystalline silica: Quartz (SiO2)
+
<!--==== Penalties Applied ====
| 100.0
+
{| class="wikitable sortable" width="95%"
| White 40/70
+
!scope="col" | Violation ID
| Proppant
+
!scope="col" | Penalty ID
| 14808-60-7
+
!scope="col" | Penalty Code
| Trican
+
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
|}
+
|}-->
For data sources see<ref>{{cite web | title = FracFocus Chemical Disclosure Registry |publisher = [http://www.fracfocusdata.org/DisclosureSearch/]| date = 2015-08-10 | url = http://wellwiki.org/wiki/Well_Chemicals_Data_Sources | accessdate = 2015-08-10 }}</ref>
+
For data sources see<ref>{{cite web
== References ==
+
| title =Oil and Gas Compliance Report
{{reflist}}
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 22:45, 15 May 2020

Well Details

Well ID: 37-115-21628
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Choconut Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 150803
Farm/Lease Name: STICKNEY 07 087 02 A 2H
License Status:
Spud Date:
Permit Date: 2014-01-16
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.958786
Longitude: -76.040292

For data sources see[1][2][3]

Well History

Date Event
2014-01-16 New Permit Application
2014-04-15 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-08-18 2014-08-18 5,973 5,469,620 34,000

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 White 40/70 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 7.92507 4,544,440.0
AI-7NR (Acid Inhibitor) Trican Acid Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00001200 6.67632
100 Mesh, Bulk (over 20K lbs)* Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 7.03571 4,034,460.0
Water Customer Carrier Water 7732-18-5 100 79.6027 45,646,200.0
FEAC-20 (Iron Control) Trican Iron Control Citric acid 77-92-9 30 0.000824 472.684
Acetic acid 64-19-7 45 0.001236 709.026
FR-8 Trican Friction Reducer Ammonium Chloride 12125-02-9 1.5 0.001073 615.07
Petroleum distillates, dewaxed heavy paraffinic 64742-65-0 8 0.005721 3280.37
Petroleum distillates, hydrotreated heavy paraffinic 64742-54-7 8 0.005721 3280.37
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 28 0.020022 11481.3
3 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 3.5 0.014263 8178.5
AQUCAR DB 5 (Water Treatment Microbiocide) Trican Biocide Sodium Bromide 7647-15-6 1.5 0.000394 226.135
Polyethylene glycol 25322-68-3 65.2 0.017141 9829.33
Dibromoacetonitrile 3252-43-5 0.5 0.000131 75.3783
2,2-dibromo-3-nitrilopropionamide 10222-01-2 5 0.001315 753.783
Other Chemicals Acrylamide 79-06-1 0 0 0
Trade Secret Proprietary 0 0 0
Water 7732-18-5 0 0 0
Polyethylene glycol monooleate 9004-96-0 0 0 0
Sorbitol Tetraoleate 61723-83-9 0 0 0
Alkyloxypolyethylene oxyethanol 84133-50-6 0 0 0
Isopropanol 67-63-0 0 0 0
Ammonium Acrylate 10604-69-0 0 0 0
Acrylamide P/W acrylic acid ammonium salt 26100-47-0 0 0 0
Sorbitan monooleate 1338-43-8 0 0 0
Nonionic Surfactant Proprietary 0 0 0
Anionic polyacrylamide copolymer Proprietary 0 0 0
LSI-21 (Scale Inhibitor) Trican Scale Inhibitor Sodium Salt of Phosphate Ester 68131-72-6 15 0.003821 2191.34
Acrylic Polymer 28205-96-1 15 0.003821 2191.34
7 1/2% HCL Trican Carrier Hydrochloric acid 7647-01-0 7.5 0.006792 3894.76
White 30/50 Trican Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 4.81129 2,758,920.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 260,140.00 54 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 896,843.70 298 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 689,579.70 365 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 467,004.70 365 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 306,542.90 358 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 21,497.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 REPSOL OIL & GAS USA LLC Fracing Fluid Waste 1,746.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 REPSOL OIL & GAS USA LLC Fracturing Fluid Waste 36.72 Tons LANDFILL 100361
2014 REPSOL OIL & GAS USA LLC Drill Cuttings 949.09 Tons LANDFILL 8-0728-0004/013
2015 REPSOL OIL & GAS USA LLC Produced Fluid 925.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 REPSOL OIL & GAS USA LLC Produced Fluid 2,000.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 7,165.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 REPSOL OIL & GAS USA LLC Produced Fluid 705.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 1,234.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 REPSOL OIL & GAS USA LLC Produced Fluid 300.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 240.00 Bbl REUSE (AT WELL PAD)
2017 REPSOL OIL & GAS USA LLC Produced Fluid 609.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 REPSOL OIL & GAS USA LLC Produced Fluid 3,952.00 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Produced Fluid 500.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 REPSOL OIL & GAS USA LLC Produced Fluid 200.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 REPSOL OIL & GAS USA LLC Produced Fluid 2,412.00 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 106.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 REPSOL OIL & GAS USA LLC Produced Fluid 1,300.00 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 60.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2252903 Primary Facility 2014-03-12 Preoperation Inspection No Violations Noted
2264852 Primary Facility 2014-04-04 Drilling/Alteration No Violations Noted Conductor set
2266737 Primary Facility 2014-04-18 Drilling/Alteration No Violations Noted Conductor set
2278099 Primary Facility 2014-05-31 Routine/Complete Inspection No Violations Noted
2291279 Primary Facility 2014-07-29 Routine/Complete Inspection No Violations Noted
2309427 Primary Facility 2014-09-15 Incident- Response to Accident or Event No Violations Noted Arrived at the site at 12:50 to conduct an inspection related to an estimated (300-400) barrel flowback fluid spill which occurred on 8/9/14. Flowback procedures and natural gas flaring were in progress as the Department arrived to the location. An excavator was in the process of removing the frac tank battery containment liner from the pad surface. The liner was being transferred to a container in preparation for disposal. The primary purpose of the inspection was to evaluate the pad surface beneath the frac tank battery containment due to the spill that occurred on 8/9/14. The pad surface was evaluated in the general vicinity where the spill occurred for evidence of contamination in the in the event of potential compromised liner integrity as the flowback fluid was spilled to containment. Based on visual observations and site evaluations, there is no evidence that the spill on 8/9/14 impacted the surface of the ground on and off the well pad.
2386093 Primary Facility 2015-07-08 Routine/Complete Inspection No Violations Noted
2440317 Primary Facility 2016-01-13 Incident- Response to Accident or Event No Violations Noted The area around the pad was stable and appeared to have all BMPs in place. There was vegetation visible on site through the snow cover.

There are no violations.

If there are any questions, please feel free to call me at (570) 346-5539.

2498588 Primary Facility 2016-07-01 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:35p.m., the cellar was full of water with no bubbling noticed, the (20x13) vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) vent pipe was open and venting into the atmosphere with no gas detected. There was 913psi on the production casing and 455psi on the production tubing. I took a walk around the location and everything looked OK.

I left the site at 12:50p.m.

2588478 Primary Facility 2017-04-27 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:50a.m.

The cellar was full of water with no bubbling noticed. The (20x13) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (13x9) annulus vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) annulus vent pipe was open and venting into the atmosphere with no gas detected. There was 550psi on the production casing and 367psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:20a.m.

2697770 Primary Facility 2018-02-15 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of water and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2793493 Primary Facility 2018-10-22 Site Restoration No Violations Noted I performed a RTNC inspection for for the Stickney well site. The site had its last company E&S inspection on 10/13/2018.
    The pad surface area was 180196 square feet.
    The weather was overcast and 40 degrees.  The pad surface and access road were dry.
    The access road was solid and firm, as was the pad surface.  The area was quite rocky.
    The cut and fill slopes were well vegetated, wherever possible.  The rocky nature of the area precludes growth where there is no soil, however wherever there was soil present, there was perennial growth exceeding 70%, as required by the Department.
    The area was stable and solid and the well was properly labeled.  The PCSM infiltration basins were installed and vegetation was adequate on the available soil.  
    There were no violations noted.
     The well was properly labeled
2794697 Primary Facility 2018-10-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of water and there was no bubbling noticed. There was a methanol tank and pump (see photo) in containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[8]