X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-113-20158"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-113-20158
 
| Well ID: 37-113-20158
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.517106, -76.466367 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.517106, -76.466367 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Regulatory Inactive Status
 
| License Status: Regulatory Inactive Status
 
|-
 
|-
| Spud Date: 05/21/2012
+
| Spud Date: 2012-05-21
 
|-
 
|-
| Permit Date: 5/10/2012
+
| Permit Date: 2012-05-10
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|}-->
 +
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 138: Line 163:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 1,058.21 Tons
 
| style="text-align: right;" | 1,058.21 Tons
Line 144: Line 169:
 
| 8-0728-0004/013
 
| 8-0728-0004/013
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 270.35 Tons
 
| style="text-align: right;" | 270.35 Tons
Line 150: Line 175:
 
| THR029
 
| THR029
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 399.52 Bbl
 
| style="text-align: right;" | 399.52 Bbl
Line 156: Line 181:
 
|  
 
|  
 
|-
 
|-
| 2012-2
+
| 2012-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 92.91 Bbl
 
| style="text-align: right;" | 92.91 Bbl
Line 181: Line 206:
 
| 2065313
 
| 2065313
 
| Primary Facility
 
| Primary Facility
| 05/02/2012
+
| 2012-05-02
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 188: Line 213:
 
| 2154979
 
| 2154979
 
| Primary Facility
 
| Primary Facility
| 03/29/2013
+
| 2013-03-29
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 195: Line 220:
 
| 2214203
 
| 2214203
 
| Primary Facility
 
| Primary Facility
| 10/09/2013
+
| 2013-10-09
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 202: Line 227:
 
| 2230506
 
| 2230506
 
| Primary Facility
 
| Primary Facility
| 12/18/2013
+
| 2013-12-18
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 209: Line 234:
 
| 2426879
 
| 2426879
 
| Primary Facility
 
| Primary Facility
| 11/18/2015
+
| 2015-11-18
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 298: Line 323:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
<!--== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|}-->
 
<!--==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|}-->
 
 
 
==References==
 
==References==
 
<references/>
 
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Pennsylvania Wells]]
 
[[Category:Pennsylvania Wells]]

Revision as of 07:36, 2 August 2019

Well Details

Well ID: 37-113-20158
Loading map...
Country: United States
State: Pennsylvania
County: Sullivan
Municipality: Cherry Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 149137
Farm/Lease Name: R&N SW SUL 4H
License Status: Regulatory Inactive Status
Spud Date: 2012-05-21
Permit Date: 2012-05-10
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.517106
Longitude: -76.466367

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2015 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2016 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2017 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S02 Drill Cuttings (in Tons) 1,058.21 Tons LANDFILL 8-0728-0004/013
2012-S02 Drill Cuttings (in Tons) 270.35 Tons LANDFILL THR029
2012-S02 Drilling Fluid Waste (in Barrels) 399.52 Bbl REUSE OTHER THAN ROAD SPREADING
2012-S02 Produced Fluid (in Barrels) 92.91 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2065313 Primary Facility 2012-05-02 Routine/Complete Inspection No Violations Noted
2154979 Primary Facility 2013-03-29 Routine/Complete Inspection No Violations Noted
2214203 Primary Facility 2013-10-09 Routine/Complete Inspection No Violations Noted
2230506 Primary Facility 2013-12-18 Routine/Partial Inspection No Violations Noted
2426879 Primary Facility 2015-11-18 Routine/Complete Inspection No Violations Noted Arrived @ 14:20. Weather cloudy, cold and windy. There were two TD’d wells: R&N SW Sul 4H (regulatory inactive status), R&N N Sul 3H (regulatory inactive status). There was also a plugged conductor-only well: the R&N SE Sul 1H, and an additional 3 water-filled cellars.
2553021 Primary Facility 2017-01-12 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess general site conditions. No Chesapeake representatives were present.

Vegetative cover on site is greater than 70%, and temporary erosion and sediment control BMPs have been removed. No evidence of accelerated erosion or sedimentation was observed.

As indicated in Chesapeake's response to the Department's June 26, 2015 letter requesting the status of all facilities, a restoration extension request is to be filed for this location. As of the date of this inspection, no request for a restoration extension has been received by the Department of Environmental Protection.

No violations were cited during this inspection.

2657912 Primary Facility 2017-11-07 Routine/Complete Inspection No Violations Noted Two wells remain covered under regulatory Inactive Status. One well plugged. No production equipment on location. Pipeline run to location. Site not restored. No PCSM controls on location.
2696265 Primary Facility 2018-02-21 Routine/Complete Inspection No Violations Noted Arrived at 11:00. Weather: sunny and warm. This location recently changed ownership from Chesapeake to Chief as reflected by pad signs. There two TD'edwells: R&N SW Sul 4H (regulatory inactive status), R&N N Sul 3H (regulatory inactive status). There was also a plugged conductor-only well: the R&N SE Sul 1H, and an additional 3 water-filled cellars.

Sul 4H: 13-3/8" x 9-5/8": no combustible gas detected, 9-5/8" x 5-1/2": no combustible gas detected. Sul 1H:13-3/8" x 9-5/8": no combustible gas detected, 9-5/8" x 5-1/2": no combustible gas detected. Sul 1H:

2792009 Primary Facility 2018-10-18 Routine/Complete Inspection No Violations Noted Weather was 40° and sunny what time inspection. There were no chief representatives on location. We had no pressure gauges attached at time of inspection. Allied horizontal wireline was on location to perform bond logs. There were 2 annulus vents plumbed to surface. One was closed in and one (20x13) was open to atmosphere at time of inspection. 0% combustible gas was detected on the annulus vent or in the area immediately surrounding the well. The well tag was removed at time of inspection due to the work being performed however it did not have the wells corresponding API number on it. No violations were noted at time of inspection.
2803146 Primary Facility 2018-11-14 Routine/Complete Inspection No Violations Noted Arrived onsite for a routine inspection at 13:15; the weather was ~30°F and calm.

There was 1 plugged well and 2 regulatory inactive wells onsite. There were a total of 6 well cellars onsite. One cellar was filled with gravel while the others were filled with water; no bubbling was observed.

There was a pipeline run to the pad but no other production equipment was onsite. The pad was well vegetated and no E&S issues were noted.

According to Department records the ESCGP for this site expired on 3/20/17 and no NOT has been submitted. However, at the time of this inspection it appeared there were pending well permits.

It is recommended that the well tags be placed on the wells themselves.

No violations were noted at the time of inspection.

For data sources see[6]

References