If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20995 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.429753,"lon":-77.058217,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Lewis Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 145123 | |
Farm/Lease Name: DCNR 100 52H 51101 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-07-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.429753 | |
Longitude: -77.058217 |
Date | Event |
---|---|
2012-07-17 | New Permit Application |
2013-01-06 | Performed Spud Operation |
2013-06-01 | Drilling Completion |
2013-10-16 | Perforation |
2014-06-11 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-10-16 | 2013-10-27 | 8,983 | 8,955,110 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | 15% HydroChloric Acid | Universal Well Services | Acid | Hydrochloric Acid HCl | 7647-01-0 | 15 | 0.00367946 | 0 |
Iron Stabilizer II | Universal Well Services | Corrosion Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.00053869 | 0 | |
CFT-2000 | Core Labs | Chemical Tracer | Proprietary Ingredient supplied as 10% w/vAqueous Solution | Proprietary | 10 | 0.00001960 | 0 | |
Water | 7732-18-5 | 90 | 0.00017639 | 0 | ||||
FlowPlus DR-5018 | Champion Technologies | Friction Reducer | Sorbitan Monoleate | 1338-43-8 | 5 | 0.00448753 | 0 | |
Hydrotreated Light Distillates | 64742-47-8 | 30 | 0.0269252 | 0 | ||||
Acrylamide | 79-06-1 | 0.1 | 0.00008975 | 0 | ||||
CFT-1200 | Core Labs | Chemical Tracer | Proprietary Ingredient supplied as 10% w/vAqueous Solution | Proprietary | 10 | 0.00001816 | 0 | |
Water | 7732-18-5 | 90 | 0.00016347 | 0 | ||||
Proppant 80/100 Oklahoma | Universal Well Services | Proppant | Silica | 14808-60-7 | 100 | 0.844682 | 0 | |
Water | Seneca Resources | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.7955 | 0 | |
Proppant 30/50 Ottawa | Universal Well Services | Proppant | Silica | 14808-60-7 | 100 | 5.13856 | 0 | |
Unihib G | Universal Well Services | Corrosion Inhibitor | Glycol Ether | 112-34-5 | 50 | 0.00022797 | 0 | |
Resin Based Nonionic Inhibitor | Proprietary | 35 | 0.00015958 | 0 | ||||
Ethoxylated Alcohol | Proprietary | 35 | 0.00015958 | 0 | ||||
CFT-1000 | Core Labs | Chemical Tracer | Water | 7732-18-5 | 90 | 0.00011966 | 0 | |
Proprietary Ingredient supplied as 10% w/vAqueous Solution | Proprietary | 10 | 0.00001330 | 0 | ||||
Gyptron T-390 | Champion Technologies | Scale Inhibitor | Nonylphenol Ethoxylate | Proprietary | 10 | 0.00096049 | 0 | |
Methanol | 67-56-1 | 10 | 0.00096049 | 0 | ||||
CFT-1100 | Core Labs | Chemical Tracer | Proprietary Ingredient supplied as 10% w/vAqueous Solution | Proprietary | 10 | 0.00000187 | 0 | |
Water | 7732-18-5 | 90 | 0.00001685 | 0 | ||||
CFT-2100 | Core Labs | Chemical Tracer | Water | 7732-18-5 | 90 | 0.00024381 | 0 | |
Proprietary Ingredient supplied as 10% w/vAqueous Solution | Proprietary | 10 | 0.00002709 | 0 | ||||
Proppant 40/70 Ottawa | Universal Well Services | Proppant | Silica | 14808-60-7 | 100 | 5.0815 | 0 | |
Bactron K-176 | Champion Technologies | Biocide | Glutaraldehyde | 111-30-8 | 30 | 0.00847384 | 0 | |
1-Decanaminium, N-decyl-N,N-dimethyl-, chloride | 7173-51-5 | 10 | 0.00282461 | 0 | ||||
Quaternary ammonium compounds, benzyl-C12-16- alkyldimethyl, chlorides |
68424-85-1 | 10 | 0.00282461 | 0 | ||||
Ethanol | 64-17-5 | 5 | 0.00141231 | 0 | ||||
7.5% HydroChloric Acid | Universal Well Services | Acid | Hydrochloric Acid HCl | 7647-01-0 | 7.5 | 0.0852616 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 2,723,036.20 | 278 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 2,461,209.98 | 354 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 1,562,945.49 | 279 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 1,413,465.34 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 1,026,801.53 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 811,507.13 | 333 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | SENECA RESOURCES CO LLC | Drill Cuttings | 1,219.65 Tons | REUSE OTHER THAN ROAD SPREADING | WMGR097R017 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 35,438.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 182.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 929.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 51.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 154.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 132.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 1,306.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 453.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 648.84 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 379.35 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 401.84 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Synthetic Liner Materials | 1.79 Tons | LANDFILL | 301358 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 41.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 108.33 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 237.51 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 5.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 21.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
2019 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 193.35 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2114099 | Primary Facility | 2012-11-07 | Routine/Partial Inspection | No Violations Noted | |
2120873 | Primary Facility | 2012-11-30 | Routine/Complete Inspection | No Violations Noted | |
2122347 | Primary Facility | 2012-12-10 | Drilling/Alteration | No Violations Noted | |
2128346 | Primary Facility | 2012-12-28 | Routine/Complete Inspection | No Violations Noted | |
2129946 | Primary Facility | 2013-01-09 | Routine/Complete Inspection | No Violations Noted | |
2140543 | Primary Facility | 2013-02-14 | Routine/Complete Inspection | No Violations Noted | |
2144094 | Primary Facility | 2013-02-26 | Drilling/Alteration | No Violations Noted | |
2166178 | Primary Facility | 2013-05-14 | Drilling/Alteration | No Violations Noted | |
2194908 | Primary Facility | 2013-08-12 | Routine/Complete Inspection | No Violations Noted | |
2221232 | Primary Facility | 2013-11-13 | Routine/Complete Inspection | No Violations Noted | |
2288874 | Primary Facility | 2014-07-22 | Routine/Complete Inspection | No Violations Noted | |
2481072 | Primary Facility | 2016-05-03 | Routine/Complete Inspection | No Violations Noted | Weather: foggy with misting rain. Arrived @ 09:30. Seven wells in a liner array. Each well had 3 stainless steel annular ¼”-diameter vent candy canes which were tagged. The 9-5/8” x 5-1/2” vents were shut-in with an in-line 0-300 psi analog gauge. Within the cellar, this annulus was also plumbed into a 2” flexible hose which linked each of the vents to a 2100-gallon poly tank. Methane gas was monitored with an Altair 5X gas meter calibrated on 04/27/16. No methane was detected at any of the vents. Methane concentrations at the vent on top of the polytank were 76% methane.
DCNR Tract 100 52H: cellar dry. Top gauge: 1616 psi (digital) 5-1/2” gauge: 1619 psi (digital) 9-5/8” x 5-1/2” gauge: 25 psi (analog). |
2596085 | Primary Facility | 2017-05-18 | Routine/Complete Inspection | No Violations Noted | Routine inspection of unconvnetional well in production. Well tag noted as incorrect. Reads 081-20998 and should read 081-20995. No violations noted a time of inspection. |
2613488 | Primary Facility | 2017-07-05 | Routine/Complete Inspection | No Violations Noted | Weather: hot and sunny. Arrived @ 14:50. Seven wells total: Six wells capable of production and one plugged well. The 9-5/8” x 5-1/2” vents were shut-in. Within the cellar, this annulus was also plumbed into a 2” flexible hose which appeared to link each of the vents to a 2100-gallon poly tank. Left @ 15:10. There were no violations at this time.
117H: 5-1/2” gauge: 467 psi (digital) 53H: 5-1/2” gauge: 427.6 psi (digital) 54H: 5-1/2” gauge: 433.1 psi (digital) 68H: 5-1/2” gauge: 410 psi (digital) 50H: plugged well, gravel-filled cellar, one candy cane vent. Monitored for methane: 0% (Altair 5X calibrated 7/5/17). 51H: 5-1/2” gauge: 377 psi (digital) 52H: 5-1/2” gauge: 560 psi (digital). Left @ 15:10 |
2815971 | Primary Facility | 2018-12-13 | Routine/Complete Inspection | No Violations Noted | Weather was 35° and cloudy at time of inspection. There were no Seneca resources representatives on location at time of inspection. Well had digital pressure monitoring equipment attached to the production casing and the production tubing. Casing pressure was 385 psi and tubing pressure was 259 psi at time of inspection. There were 3 annulus vents plumbed to surface at time of inspection. The 20x13 and 13x9 annulus had 0% combustible gas detected. The 9x5 annulus had 15% methane detected at time of inspection. No violations were noted at time of inspection. |
For data sources see[8]