X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-059-26172"

Line 895: Line 895:
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
 
  | title =FracFocus Fracking Chemicals Database
 
  | title =FracFocus Fracking Chemicals Database
|publisher = Joel Gehman
 
 
| date = 2019-04-02
 
| date = 2019-04-02
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources

Revision as of 10:06, 10 July 2019

Well Details

Well ID: 37-059-26172
Loading map...
Country: United States
State: Pennsylvania
County: Greene
Municipality: Dunkard Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 144823
Farm/Lease Name: MILLER UNIT 82H
License Status: Active
Spud Date: 06/09/2013
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.7850
Longitude: -80.028694

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 227,912.00 50 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 268,516.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 194,659.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 170,307.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 136,578.00 335 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 33,581.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2013-1 Drill Cuttings (in Tons) 354.62 Tons LANDFILL 100419
2013-2 Drill Cuttings (in Tons) 761.49 Tons LANDFILL 100172
2013-2 Drilling Fluid Waste (in Barrels) 2,100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014-1 Drill Cuttings (in Tons) 2.21 Tons LANDFILL 100172
2014-1 Fracing Fluid Waste (in Barrels) 10.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014-1 Fracing Fluid Waste (in Barrels) 594.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014-1 Fracing Fluid Waste (in Barrels) 180.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Fracturing Fluid Waste (in Tons) 0.51 Tons LANDFILL 100172
2014-1 Fracturing Fluid Waste (in Tons) 0.96 Tons LANDFILL 100663
2014-2 Fracing Fluid Waste (in Barrels) 4,134.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014-2 Fracing Fluid Waste (in Barrels) 3,146.72 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Fracturing Fluid Waste (in Tons) 26.65 Tons LANDFILL 100172
2015-1 Fracing Fluid Waste (in Barrels) 2,063.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015-1 Fracing Fluid Waste (in Barrels) 292.14 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Fracturing Fluid Waste (in Tons) 1.47 Tons LANDFILL 100419
2015-1 Fracturing Fluid Waste (in Tons) 14.39 Tons RESIDUAL WASTE TRANSFER FACILITY MID074259565
2015-1 Produced Fluid (in Barrels) 157.29 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015-1 Produced Fluid (in Barrels) 5,587.57 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Fracturing Fluid Waste (in Tons) 0.23 Tons LANDFILL 073 114 654
2015-2 Produced Fluid (in Barrels) 3,731.43 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 37.14 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-1 Produced Fluid (in Barrels) RWC 802 2,226.94 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 1,536.69 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016-2 Produced Fluid (in Barrels) RWC 802 234.01 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 30.00 Bbl INJECTION DISPOSAL WELL 34-059-24202
2017-01 Produced Fluid (in Barrels) RWC 802 176.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-02 Produced Fluid (in Barrels) RWC 802 214.89 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-03 Produced Fluid (in Barrels) RWC 802 125.74 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-03 Produced Fluid (in Barrels) RWC 802 89.66 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 54.29 Bbl REUSE (AT WELL PAD)
2017-05 Produced Fluid (in Barrels) RWC 802 690.00 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 64.29 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017-06 Produced Fluid (in Barrels) RWC 802 35.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-06 Produced Fluid (in Barrels) RWC 802 17.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-06 Produced Fluid (in Barrels) RWC 802 18.57 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 77.14 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017-07 Produced Fluid (in Barrels) RWC 802 15.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017-07 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 27.14 Bbl INJECTION DISPOSAL WELL 34-059-24202
2017-08 Produced Fluid (in Barrels) RWC 802 14.29 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017-08 Produced Fluid (in Barrels) RWC 802 33.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-08 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 30.00 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 30.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-10 Produced Fluid (in Barrels) RWC 802 15.03 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-10 Produced Fluid (in Barrels) RWC 802 17.14 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 62.86 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-11 Produced Fluid (in Barrels) RWC 802 17.14 Bbl INJECTION DISPOSAL WELL 34-157-25511
2017-11 Produced Fluid (in Barrels) RWC 802 29.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017-11 Produced Fluid (in Barrels) RWC 802 106.26 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-12 Produced Fluid (in Barrels) RWC 802 149.43 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-01 Produced Fluid (in Barrels) RWC 802 31.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018-01 Produced Fluid (in Barrels) RWC 802 127.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-02 Produced Fluid (in Barrels) RWC 802 16.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-02 Produced Fluid (in Barrels) RWC 802 66.00 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 32.14 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-03 Produced Fluid (in Barrels) RWC 802 26.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-03 Produced Fluid (in Barrels) RWC 802 16.43 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 30.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-04 Produced Fluid (in Barrels) RWC 802 30.71 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-05 Produced Fluid (in Barrels) RWC 802 46.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-05 Produced Fluid (in Barrels) RWC 802 14.29 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 27.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-07 Produced Fluid (in Barrels) RWC 802 32.14 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 47.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-08 Produced Fluid (in Barrels) RWC 802 107.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-09 Produced Fluid (in Barrels) RWC 802 30.00 Bbl REUSE (AT WELL PAD)
2018-09 Produced Fluid (in Barrels) RWC 802 84.29 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-11 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 95.57 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-12 Produced Fluid (in Barrels) RWC 802 16.43 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 80.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-01 Produced Fluid (in Barrels) RWC 802 48.57 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 17.14 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 15.71 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-03 Produced Fluid (in Barrels) RWC 802 17.14 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2189105 Primary Facility 07/12/2013 Drilling/Alteration No Violations Noted Conductor set waiting for Top Hole Rig to skid to well and commence drilling.
2334363 Primary Facility 10/06/2014 Routine/Complete Inspection No Violations Noted Well being placed into production.
2356489 Primary Facility 02/24/2015 Routine/Complete Inspection No Violations Noted
2380291 Primary Facility 06/04/2015 Routine/Complete Inspection No Violations Noted
2487924 Primary Facility 2016-05-25 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, Restoration in process.
2549798 Primary Facility 2016-12-08 Routine/Complete Inspection No Violations Noted On 12/08/16 at approximately 0930 hours I conducted a routine complete inspection of the Miller Unit. The Act 9 sign was in place and all required documents were present at the site. The pad was fenced and gated. The site was well vegetated and it appeared Chevron had recently seeded and mulched a small area to the north of the access road. There was no erosion observed at the time of inspection. There were no violations observed at the time of inspection.
2623730 Primary Facility 2017-08-07 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. One location along the access road appeared to have been seeded and mulched. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2636988 Primary Facility 2017-09-15 Site Restoration No Violations Noted A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved.
2663942 Primary Facility 2017-11-16 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.
2752975 Primary Facility 2018-07-17 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth Total Water Volume Total Non-Water Volume
1 06/25/2014 07/07/2014 7968 1.77103e+007

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used
1 J580 Schlumberger Gelling Agent Carboydrate polymer Proprietary 100 0.0768114 0
J134 Schlumberger Gel Breaker Hemicellulase Enzyme 9012-54-8 100 0.0029826 0
A264 Schlumberger Iron Control Prop-2-yn-1-ol 107-19-7 10 1.316e-005 0
Aliphatic alcohols, ethoxylayed #1 Proprietary 30 3.948e-005 0
Aliphatic acids Proprietary 30 3.948e-005 0
Methanol 67-56-1 40 5.264e-005 0
EC6673W Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00196904 0
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00082436 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 6.78438 0
15% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 15 0.0200733 0
EC6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00075436 0
Polyethylene Glycol 25322-68-3 60 0.00150872 0
Dibromoacetonitrile 3252-43-5 5 0.00012573 0
Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 92.9868 0
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00038052 0
J609 Schlumberger Friction Reducer Ammonium Sulfate 7783-20-2 30 0.0290347 0

For data sources see[7]

References