Well Details

Well ID: 34-157-25511
Loading map...
Country: United States
State: Ohio
County: Tuscarawas
Municipality: Oxford Township
Operator Name: PRODUCED WATER TRANSFER1 LLC
Well Pad ID:
Farm/Lease Name: MOZENA (SWIW #13)
License Status: Active Injection
License Date: 2014-08-04
Spud Date: 2014-05-19
Spud Drilling Contractor: WHIPKEY DRLG
Final Drill Date:
Well Total Depth: 8260.00 ft
Configuration: Vertical
Latitude: 40.280000
Longitude: -81.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-04-25 Proposed Formations:MT.SIMON, Issued Date:4/25/2014, Expired Date:4/24/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:EDPW
Annulus Pressure Monitoring Approved 2014-07-07
APP 2014-08-04 Proposed Formations:MT SIMON, Issued Date:8/4/2014, Expired Date:8/3/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:
Last Compliance Report 2014-08-06
Construction Permit Expires 2016-08-03
Record Last Modified 2018-11-29

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-08-06 7150 8260 0
7150 8260 0
7150 8260 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1009563685 2020-3-17 0:00: SW No Violations
-1018652187 2019-9-16 0:00: SW No Violations
-1150365657 2019-9-9 0:00:0 SW No Violations
-1191030709 2019-12-10 0:00 SW No Violations
-1219606449 2019-3-20 0:00: SW No Violations
-1227804908 2016-7-14 0:00: SW No Violations
-1248046662 2018-3-12 0:00: SW No Violations
-1301579320 2019-4-14 0:00: SW No Violations
-1341669515 2018-1-16 0:00: SW No Violations
-1345108355 2014-7-2 0:00:0 PW No Violations
-1348262062 2015-10-13 0:00 SW No Violations
-1364135361 2017-1-9 0:00:0 SW No Violations
-1372806805 2016-3-2 0:00:0 SW No Violations
-1387398780 2015-5-22 0:00: SW No Violations
-1399651993 2014-6-4 0:00:0 DD No Violations
-1406691069 2020-4-28 0:00: SW No Violations
-1428965005 2018-11-23 0:00 SW No Violations
-1499239441 2014-7-31 0:00: SW No Violations
-1518540679 2017-5-16 0:00: SW No Violations
-1552588113 2019-11-27 0:00 SW No Violations
-1572632427 2016-1-19 0:00: SW No Violations
-159596667 2020-4-14 0:00: SW No Violations
-1607585059 2019-2-26 0:00: SW No Violations
-1613641232 2018-12-5 0:00: SW No Violations
-1623606910 2020-7-8 0:00:0 SW No Violations
-1632710939 2017-3-1 0:00:0 SW No Violations
-1633751540 2018-6-21 0:00: SW No Violations
-1663370848 2017-11-29 0:00 SW No Violations
-1717402096 2015-7-9 0:00:0 SW No Violations
-1737527093 2018-8-10 0:00: SW No Violations
-1753402116 2015-4-3 0:00:0 BH No Violations
-1760953633 2017-4-7 0:00:0 SW No Violations
-1808500377 2017-12-18 0:00 SW No Violations
-1816554862 2016-12-30 0:00 SW No Violations
-1855768081 2015-4-22 0:00: SW No Violations
-1895994736 2019-4-24 0:00: SW No Violations
-1899484079 2020-6-18 0:00: SC No Violations
-1899601043 2016-7-19 0:00: SW No Violations
-1910890424 2015-10-28 0:00 SW No Violations
-1937560577 2018-3-5 0:00:0 SW No Violations
-1939537891 2019-12-31 0:00 SW No Violations
-1985416438 2015-7-9 0:00:0 BH No Violations
-2033900620 2019-4-2 0:00:0 SW No Violations
-2081242459 2018-11-2 0:00: SW No Violations
-2119462763 2017-4-20 0:00: SW No Violations
-246039266 2014-10-22 0:00 SW No Violations
-246665502 2020-1-14 0:00: SW No Violations
-247731442 2015-7-29 0:00: SW No Violations
-339751641 2019-12-4 0:00: SW No Violations
-379387863 2014-5-30 0:00: DD No Violations
-381893134 2017-7-14 0:00: SW No Violations
-417639924 2017-1-26 0:00: SW No Violations
-436630902 2018-8-7 0:00:0 SW No Violations
-449188194 2015-9-8 0:00:0 SW No Violations
-4885021 2016-2-22 0:00: SW No Violations
-504428983 2016-8-8 0:00:0 SW No Violations
-51969790 2019-4-3 0:00:0 SW No Violations
-543931964 2015-5-1 0:00:0 SW No Violations
-577186251 2015-3-13 0:00: SW No Violations 3.00
-601613699 2018-8-27 0:00: SW No Violations
-621375106 2018-10-4 0:00: SW No Violations
-639007716 2015-3-23 0:00: SW No Violations
-678575967 2016-9-19 0:00: SW No Violations
-714334636 2014-6-2 0:00:0 DD No Violations
-74323686 2016-2-2 0:00:0 SW No Violations
-775668292 2016-9-8 0:00:0 SW No Violations
-813619563 2015-6-11 0:00: SW No Violations
-82647487 2016-6-1 0:00:0 SW No Violations
-832055935 2019-7-5 0:00:0 SW No Violations
-939565151 2019-7-18 0:00: SW No Violations
-976173619 2015-7-9 0:00:0 BH No Violations
0004885021 2016-02-22 Salt Water Injection Well No Violations Inspection today indicated that three Myers tankers were on site and I checked wet weather ditch for signs of chlorides I ran a quantab test strip with a reading of .6 which indicates water is well below current EPA standards for fresh water.
0051969790 2019-04-03 Salt Water Injection Well No Violations On site today to witness Producers Services perform 1500 gallon acid treatment on well.

1000 galllon of HCL type 500 gallon of HF type Operator displaced acid to formation with injection pump.

0074323686 2016-02-02 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection and it was noted that two SUNPRO vacuum trucks were unloading at the facility today.
0082647487 2016-06-01 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection and it was noted that three Ridge Runner vacuum trucks were unloading at the facility during my inspection.
0083047851 2017-09-06 Salt Water Injection Well No Violations Inspection revealed that all three injection pumps were in operation today.


Note: One 25-598 vacuum truck on site and three 25-647 tankers were on site.

0136513867 2017-06-08 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were not in operation and it was noted that one Meyers truck and two Deepwell trucks were unloading at the facility during my inspection.
0245825086 2016-03-07 Salt Water Injection Well No Violations Injection pumps were in operation during my inspection.
0246039266 2014-10-22 Salt Water Injection Well No Violations Inspection revealed that there was two Myers Water Service tankers on site during my inspection and according to owner they are receiving approximately 2400 barrel of water per day.
0247731442 2015-07-29 Salt Water Injection Well No Violations Inspection on this day indicated that all three injection pumps were in operation and it was noted that owner has recently built a cellar around wellhead and it is covered with grating to ensure no one will fall into cellar area.
0252516445 2017-03-24 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were not in operation during my inspection.
0307900257 2016-10-18 Salt Water Injection Well No Violations Injection pumps were in operation today.
0358026225 2014-11-10 Salt Water Injection Well No Violations Inspection revealed that temporary injection pump was in operation during my inspection and it was noted that one Nabors Water Service tanker was unloading at the facility during my inspection.
0367978733 2014-09-23 Salt Water Injection Well No Violations Inspection revealed that owner has begun to move dirt for permanent tank site and restoring drill site and they are getting ready to place the outer casing going to the well from tank site which will have the injection flow line inside of it once they have permanent facility built.
0373959078 2016-01-07 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that Germantown Electrical contractor was on site installing heaters in office shed and control room and I had conversation with well owner concerning getting vegetation established in area below vault for unloading pad and also in area of where temporary storage tanks were placed while facility was being built and we agreed that as soon as spring weather arrived they will address those areas.
0377739541 2015-04-07 Salt Water Injection Well No Violations Inspection revealed that both injection pumps were in operation during my inspection and it was noted that three Hall Drilling vacuum trucks were unloading during the time of my inspection.
0379387863 2014-05-30 Drill / Deepen / Reopen No Violations Inspection revealed that Whip Stock rig one was drilling on air/foam@ 6040 deep and they plan on making another bit trip just above the Rose Run sandstone.
0381893134 2017-07-14 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation and it was noted that one COYLE tanker was on site unloading they were operating under 25-633 UIC number which I told driver that they needed to have 633 list them as being leased to them and there info would need to be on the truck along with telephone number I took several photos of truck and sent them up to Central office for futher review.
0417639924 2017-01-26 Salt Water Injection Well No Violations Inspection today revealed that all three injection pumps were in operation and it was noted that one SUNPRO vacuum truck was unloading at the facility during my inspection.
0424171960 2017-08-08 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation during my inspection and it was noted that Myers and Deepwell and Youngs Trucking was at the facility unloading during my inspection.
0429717537 2014-10-02 Salt Water Injection Well No Violations Inspection revealed that owner has placed concrete in pump house area and unloading pad area and they plan on starting tank construction next week on tank number one and also they plan on placing flow line to wellhead and it will be casing within a larger diameter casing.
0436630902 2018-08-07 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation and it was noted that facility was extremely busy today we audited 27 different trucks during our time on site.
0449188194 2015-09-08 Salt Water Injection Well No Violations Inspection revealed that two injection pumps were in operation today an welder was working on the plumbing on the third pump repairing washed out fitting and it was noted that three Royal Flush vacuum trucks were unloading at the facility during my inspection.
0471203664 2018-07-05 Salt Water Injection Well No Violations Inspection revealed that injection pumps were not in operation during my inspection.
0485095522 2018-04-10 Salt Water Injection Well No Violations Inspection revealed that they were still prepping site for storage tank cleanout.
0504428983 2016-08-08 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation during my inspection.
0505373216 2018-08-01 Salt Water Injection Well No Violations On site today performing truck audits, there was nineteen various trucks offloading during our time on site and all was properly labeled.
0513833351 2014-10-15 Salt Water Injection Well No Violations Owner placing flow line to wellhead and storage tank construction is under way and owner thinks they should be done within the next couple weeks.
0518028283 2015-03-11 Brine Hauler No Violations Field Audit: 9 brine haulers on site. (6) Myers Trucking (UIC # 25-427) all labeled correctly (1) First Oilfield Services Truck (UIC # 25-595) also labeled correctly. However, Myers Well Service and First Oilfield Services have not modified their plan to include the Mozena #1 well as a disposal site. Called both companies and sent a letter to notify them to modify their existing disposal plan ASAP. (2) SunPro (UIC #25-418) were also on site, labeled correctly and approved to haul to the Mozena #1 well.
0539324804 2015-09-30 Salt Water Injection Well No Violations Inspection on this day indicated that injection pumps were in operation and it was noted that several Meyers Water trucks were unloading at the facility during my inspection.

Note: Dike has been reworked and owner is currently making plans to install sumps in the southeast and southwest corners of containment area.

0543931964 2015-05-01 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that several different water haulers were waiting to unload today.
0551908148 2017-04-07 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were not in operation during my inspection.
0577186251 2015-03-13 Salt Water Injection Well No Violations On site to witness Producers Services perform 1500 gallon acid treatment on said well and also pressure test annulus of tubing.

Note: 420 psi is what we tested annulus of tubing and acid treatment was 500 gal of 28% acid and 1000 gal of HF type acid.

0599981279 2017-10-02 Salt Water Injection Well No Violations Inspection today revealed that all three injection pumps were in operation during my inspection and it was noted that two Royal Flush vacuum trucks and one Youngs tanker was unloading at the facility today.
0601613699 2018-08-27 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection and it was noted that facility was extremely busy today.
0615039157 2017-08-23 Surface Facility Construction No Violations Inspection today indicated that all three injection pumps were in operation during my inspection and it was noted that there was 12 vacuum trucks waiting to unload at the facility during my inspection.
0621375106 2018-10-04 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation during my inspection.

Note: Facility was busy today 27 various brine trucks were on site waiting to offload during my time on site.

0639007716 2015-03-23 Salt Water Injection Well No Violations Inspection revealed that owner is now using the permanent facility and that have started cleaning tanks in the temporary storage tank area.

Note: Suggested to owner that they have roll off box full of used filters hauled off to a approved landfill and I needed documentation of where material was properly disposed of.

0678575967 2016-09-19 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation and it was noted that two Sunpro vacuum trucks were offloading during my inspection.
0714334636 2014-06-02 Drill / Deepen / Reopen No Violations Inspection revealed that they were drilling@6964 on fluid and they are not losing any fluid in well bore at this time.
0722358874 2014-09-04 Salt Water Injection Well No Violations Company rep on site pumping on well at 2-3 bbl. per minute at a pressure of 50-75 psi and they plan on pumping fluid for 48 hour test.
0726456178 2015-08-12 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation(2) on the day of my inspection and it was noted that four Meyers vacuum trucks were unloading at the facility on this day.
0754278943 2018-09-26 Salt Water Injection Well No Violations On site performing truck audits today.


Note: Eighteen brine trucks on site during audit session.

0775668292 2016-09-08 Salt Water Injection Well No Violations Inspection today revealed that all three injection pumps were in operation and there was nine Myers vacuum trucks waiting to unload at the facility during my inspection.
0813619563 2015-06-11 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation today and it was noted that four Myers Vacuum Trucks were unloading at the facility during my inspection.

UIC# 25-427.

0814368404 2015-02-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that three Meyers vacuum trucks were unloading at the facility during my inspection.

Note: Cement contractor was onsite preparing to install new floor in the west storage tank.

0831806840 2017-02-23 Salt Water Injection Well No Violations On this day of my inspection it was determined that injection pumps were not in operation and it was stated by employees that they have been slow receiving water for disposal.
0920989644 2015-09-24 Salt Water Injection Well No Violations Inspection on this day indicated that injection pumps were in operation and it was also noted that owner has been making upgrades to current dike he has hauled in 250 ton of soil to enable contractor to raise dike wall and once liner is reattached they will cover exposed portions of liner with soil so it is not exposed to the sunlight and then they will establish vegetation on dike walls.

Note: Owner is also planning on doing remedial work on drill site too establish better vegetation to help bind soils and prevent erosion issues.

0928603875 2015-04-13 Salt Water Injection Well No Violations Inspection revealed that both injection pumps were in operation during my inspection and it was noted that Myers Water Services and Clearcreek both had two vacuum trucks unloading at the facility during my inspection.
0970179515 2015-03-12 Salt Water Injection Well No Violations On site to check on storage tank(west side) owner has begun to fill it with fresh water and if no leaks are detected once full and we monitor it for 72 hours and if no leaks are found they will drain it and refill with brine and properly dispose of it down hole.
0976173619 2015-07-09 Brine Hauler No Violations PERFORMED FIELD AUDIT OF BRINE TRUCKS:(6) STALLION OILFIELD CONSTRUCTION LLC UIC #25-368 ON SITE LABELED PROPERLY BUT NOT APPROVED TO HAUL TO THE SOS D-1 WELL. LETTER SENT REQUESTING MODIFICATION OF DISPOSAL PLAN APPLICATION FORM 12. (1) ENVIRONMENTAL MANAGEMENT SPECIALISTS INC UIC #25-637 ON SITE LABELED PROPLERLY AND APPROVED TO HAUL TO THE SOS D-1
1010387015 2016-06-27 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection.

Note: Landowner has worked up field to meet his expectations with proper drainage and corrected vegetation to meet his standards and he applied seed and mulch to the reworked areas and new growth has began to grow.

1015408436 2015-12-11 Salt Water Injection Well No Violations Inspection revealed that there was no activity at the site during my inspection.
1018817820 2014-05-27 Drill / Deepen / Reopen No Violations Inspection revealed that Whip stock drilling was at a depth of 4705 soaping and they plan on making bit trip three kellys into the Queenstown shale.
1029591739 2019-6-19 0:00: SW No Violations
1038831879 2014-06-06 Drill / Deepen / Reopen No Violations Whipstock drilling at 8074 in the Rome section of well they should be at total depth tomorrow.
1101984780 2019-8-21 0:00: SW No Violations
1141562090 2016-06-08 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection.
1144951095 2018-07-30 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection.

Note: Truck traffic at the well site was heavy during my inspection.

1214528771 2018-04-09 Salt Water Injection Well No Violations Inspection revealed that injection pumps were not in operation during my inspection and in conversation with workers they are preparing for tank cleanout operations.
1219340037 2016-11-07 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
1219606449 2019-03-20 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation during our inspection.


Truck audits.

1227804908 2016-07-14 Salt Water Injection Well No Violations Inspection revealed that two out of the three injection pumps were in operation during my inspection.
1248046662 2018-03-12 Salt Water Injection Well No Violations Inspection today revealed that two of the three injection pumps were in operation during my inspection.


Note: Seventeen vacuum trucks on site waiting to unload during my inspection.

1259543149 2018-08-16 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation today.

On site to witness liner being installed in additional storage area.

1267994420 2017-06-01 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were not in operation during my inspection and it was noted that one Deepwell vacuum truck was on site unloading during my inspection.
1291021999 2017-05-09 Salt Water Injection Well No Violations Inspection revealed that only two injection pumps were in operation during my inspection.
1301579320 2019-04-14 Salt Water Injection Well No Violations Inspection revealed that injection pumps were not in operation during my inspection.

One Ryan Environmental truck on site during inspection.

1341669515 2018-01-16 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation during my inspection and it was noted that facility was extremely busy today.
1345108355 2014-07-02 Production Wells No Violations On site to witness tubing and packer run into well on this day they were unable to start job due to missing components on working string.
1346449104 2014-09-30 Salt Water Injection Well No Violations Well not in operation today and it was noted that one Myers Water Service had one tanker on site unloading into there temporary storage tank during my inspection.

Note: Drilling pits have been closed and drill site roughed in waiting on final grade to be made once flow line is put into place.

1348262062 2015-10-13 Salt Water Injection Well No Violations Inspection on this day indicated that injection pumps were in operation today.


Note: Met with well owner Mike Chapin to discuss completing preliminary restoration at the site it is over due to wet weather conditions and we talked about hauling in soil to level up field for better water drainage and to help get vegetation established in a timely manner.

1364135361 2017-01-09 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation today and it was noted that five ECM vacuum trucks were unloading at the facility during my inspection.
136513867 2017-6-8 0:00:0 SW No Violations
1372806805 2016-03-02 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation and it was noted that three Myers tankers were unloading at the facility during my inspection.
1387398780 2015-05-22 Salt Water Injection Well No Violations Inspection revealed that all three injection pumps were in operation today and there was several brine haulers on site during my inspection.

Hauler#s 25-591,25-600,25-533,and roll off box containing filters have been hauled away and additional roll off boxes full of solidified material has also been removed from site and I contacted Mike Chapin and requested manifest records of material removed from site.

1399651993 2014-06-04 Drill / Deepen / Reopen No Violations Inspection revealed that Whip Stock Drilling was at 7465 drilling on fluid and they anticipate being at total depth in the next couple of days.

Note: Formation tops are as follows Big Injun476-558 Berea 928-981,Lime 3052,Newburg 4211-4268,Clinton 4563-4656,Medina 4712-4727,Utica 5952-6073, Trenton 6190-6310,Rose Run 71107230, Rome 7735-8260.Mt. Simon 8260-8361.

1400284068 2014-05-15 Drill / Deepen / Reopen No Violations Whip stock Drilling rigging up preparing to start drilling on Monday 5/19/14.
1404481029 2014-07-03 Production Wells No Violations On site to witness tubing and packer run into well along with two division staff members,Kilbarger Services and Halliburton staff made up packer and started tubing in well and they set packer at 7150 and we will pressure test casing and tubing on 7/7/14.

Note: Packer is set in 35K compression.

1409869377 2014-09-03 Salt Water Injection Well No Violations Inspection revealed that Baker Wireline set down hole pressure gauges in well in preparation for pressure falloff testing.
1418592000 2014-12-12 Salt Water Injection Well No Violations Owner had Producers Services perform 1000 gal acid treatment on said well.
1420098974 2015-12-18 Salt Water Injection Well No Violations No activity at the site during my inspection.

Vegetation in area of well head beginning to grow landowner is concerned with sparsely vegetated areas told him to be patient it will fill in if not they will reapply more seed in the spring.

1420297093 2015-01-02 Salt Water Injection Well No Violations Inspection revealed that owner has storage tanks nearly completed and they plan on test permanent injection line the first of the week and once line is tested they plan on filling one of the storage tanks with fresh water and we will monitor tank for 72 hours to look for any potential leaks and if none are found we will then transfer water to the other tank and repeat process.
1421708614 2015-01-19 Salt Water Injection Well No Violations On site to witness pressure testing of 4 steel flow line to wellhead we pressured up to 1820 psi and monitored pressure for 15 minutes with no decline in pressure (TEST PASSED).
1423399025 2015-02-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that permanent storage tanks are nearly complete and once they are completed we will hydro test them with fresh water for 72 hours to monitor for possible leakage if none are found drain tanks and fill with brine for disposal.
1424894546 2015-02-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and I was on site to witness contractor place concrete in the base area of the east tank and once it is cured they will install new tank bottom and then we will hydro test tank with fresh water and once tank is full we will monitor it for any leakage for 72 hours and if no leaks are found they will drain tank and fill with brine and place tank into operation.
1428965005 2018-11-23 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation and it was noted that contractor was on site working on plumbing on new 10,000bbl. Tank projected that they should be ready to start hydro testing tank possibly late next week.
1434236665 2015-06-09 Salt Water Injection Well No Violations Inspection revealed that all three injection pumps were in operation during my inspection and it was noted brine hauler#25-528 was unloading at the facility during my inspection.
1440601744 2015-08-20 Salt Water Injection Well No Violations Inspection revealed that Producers Services was on site to perform 1500 gal. acid treatment on said well.
1442699166 2015-09-15 Salt Water Injection Well No Violations Inspection on this day indicated that only two injection pumps were in operation during my inspection and it was noted that three Royal Flush vacuum trucks were unloading at the facility at the time of my inspection.
1447240838 2015-11-09 Salt Water Injection Well No Violations Inspection on this day indicated that contractor was placing soil in low lying areas around drill site to help with drainage issues brought up by landowner and I told contractor to seed and mulch these affected areas once restoration work was completed and field was restored to landowners satisfaction.

Note: Injection pumps were not in operation during my inspection today.

1447969338 2015-11-18 Preliminary Restoration No Violations Restoration work at the site has been completed the area around well site has been graded and fertilizer and seed and mulch has been applied and vegetation has begun to grow will monitor growth and if needed will have company reapply seed and mulch in the spring to control any potential erosion issues that may arise.
1448718207 2015-11-25 Preliminary Restoration No Violations Restoration work at site is satisfactory owner has recently reworked site and seed and mulch was applied to sparsely vegetated areas and currently vegetation has begun to grow and there was drainage ditches installed to help with standing water on the site.
1449090277 2015-12-01 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection.
1453251700 2014-06-18 Production Wells No Violations Inspection revealed that drilling rig has completed drilling the well to a total depth of 8260 and location revealed that the pits are still in need of closure and site has been roughed in waiting on owner to complete well.
1453757363 2016-01-25 Salt Water Injection Well No Violations Inspection on this day indicated that injection pump was in operation and it was noted that two Royal Flush vacuum trucks were on the unloading pad during my inspection.

Note: Contractor was on site applying seed and mulch in the area of temporary storage area that was used when permanent facility was being constructed will see if vegetation is established in the spring.

1458790949 2017-11-14 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation and it was noted that two ECM tankers and one Ramco tanker was unloading brine during my inspection.
1464124246 2016-05-24 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation and landowner flagged me down to discuss two low spots in field that he would like owner to add soil and seed and mulch to these two affected areas told him I would speak to well owner and let him be aware of his concerns.
1466542685 2016-06-21 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were not in operation and in conversation with workers stating it has been slow this week and it was noted that landowner was grading field to make it level to meet his approval there was vegetation established and landowner stated he will reapply seed and mulch to the affected areas.
1471552123 2016-08-16 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection and it was noted one Petta Enterprises truck and one C J Trucking tanker was unloading at the site today.
1479511250 2016-11-16 Salt Water Injection Well No Violations Inspection revealed that injection pumps were not in operation during my inspection.

Note: Two 25-456 brine trucks were unloading at the facility during my inspection.

1480365824 2016-11-28 Salt Water Injection Well No Violations Inspection today indicated that two of the three injection pumps were in operation and it was noted that one ECM Tanker was unloading at the site today(25-548)brine hauler number.
1482257464 2016-12-20 Preliminary Restoration No Violations Restoration work at site is satisfactory pits were filled in and site reclaimed and vegetation has been established.
1487969459 2017-02-23 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were not in operation during my inspection and it was noted that Ergon Ooil tanker was onsite picking up a load of oil.
1497982048 2017-06-19 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were not in operation during my inspection and it was noted that one Deepwell vacuum truck was unloading at the facility on this day of my inspection.
1499239441 2014-07-31 Salt Water Injection Well No Violations Met with Mike Chapin to discuss constructing temporary facility at site,we went over containment requirements and temporary unloading pad requirements also and he stated he would submit plan to UIC department for approval.
1501013651 2017-07-25 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were not in operation during my inspection.
1502980794 2017-08-14 Salt Water Injection Well No Violations Inspection today indicated that all three injection pumps were in operation during my inspection and it was noted that two Royal Flush vacuum trucks were unloading at the site during my inspection.
1505412237 2017-09-13 Salt Water Injection Well No Violations Inspection today indicated that all three injection pumps were in operation during my inspection and it was noted that four MYERS tankers were unloading at the facility during my inspection.
1509781840 2017-11-02 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation and facility was noted to be busy today.

Noted that six Myers tankers and four ECM tankers and two Royal Flush vacuum trucks were waiting to offload during my inspection.

1510086917 2017-11-06 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation during my inspection and it was noted that two ECM tankers and two Royal Flush vacuum trucks were unloading at the facility during my inspection
1511789441 2017-11-24 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation and it was noted that four Sunpro tankers and six Myers tankers were on site during my inspection.
1518540679 2017-05-16 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection.
1519929075 2018-02-26 Salt Water Injection Well No Violations Inspection revealed that two of the three injection pumps were in operation during my inspection and it was noted that twenty seven brine trucks were on site waiting to offload during my inspection.
1522768178 2018-04-03 Salt Water Injection Well No Violations Inspection today indicated that two injection pumps were in operation during my inspection and it was noted that roll off box containing used filters is in need of being emptied owner stated that he is waiting on analytical report to come back so he can ship filters to approved disposal site.
1523909617 2018-04-15 Salt Water Injection Well No Violations Inspection today indicated that one injection pump was in operation during my inspection and it was noted that storage tank fluids are being cleaned at this present time.

Note: Six Royal Flush vacuum trucks were on site unloading during my inspection.

1524684845 2018-04-22 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation during my inspection and it was noted that facility was extremely busy during my inspection, brine was coming in from CNX site in PA.
1527788348 2018-05-30 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were not in operation at the time of my inspection.
1529255317 2018-06-14 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation during our inspection.

Five-Clearcreek trucks 25-474 Four-Deepwell 25-600 Five-Royal 25-549 One-Gasfield Services 25-684 Sixteen brine trucks on site during our inspection.

1531862217 2018-07-16 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.


Note: Two Oil Hauler vacuum trucks on site during my inspection.

1536961162 2018-09-12 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and it was noted that 22 various brine trucks were on site during my inspection..
1538762037 2018-10-02 Salt Water Injection Well No Violations Inspection today indicated that two injection pumps were in operation during my inspection and it was noted that new 10,000 bbl. water storage tank is under construction.

Facility extremely busy today.

1542827852 2018-11-20 Salt Water Injection Well No Violations Inspection today indicated that all three injection pumps were in operation and it was noted that four Oil Haulers vacuum trucks were on site offloading during our inspection.


Truck audits today.

1546025743 2018-12-26 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation and injecting to both wells on the day of my inspection.
1570741754 2019-10-7 0:00: SW No Violations
1572632427 2016-01-19 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation and it was noted that two CJ Trucking vacuum trucks were unloading at the facility during my inspection.
1573364046 2019-7-10 0:00: SW No Violations
1574283677 2019-11-15 0:00 SW No Violations
1577544510 2019-12-26 0:00 SW No Violations
1579969012 2020-1-22 0:00: SW No Violations
1580509337 2020-1-30 0:00: SW No Violations
1586543909 2020-4-9 0:00:0 SW No Violations
1593270445 2020-6-24 0:00: SW No Violations
1601018326 2018-08-17 Salt Water Injection Well No Violations Witness contractor place sand on exposed portion of new liner that was placed in need containment area.
1605062702 2014-09-12 Salt Water Injection Well No Violations Inspection revealed that owner is constructing temporary storage area for six 500 barrel tanks and temporary unloading pad area and a area for injection pump to be placed he plans on to start using site for active injection facility while he waits on permanent facility to be constructed.
1607585059 2019-02-26 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation today(4) pumps in operation and there was several brine haulers on site waiting to offload.


Truck audits.

1613641232 2018-12-05 Salt Water Injection Well No Violations On site today to perform truck audits.


Note: 21 various brine haulers on site during audit session.

1632710939 2017-03-01 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that 2-Dow Cameron trucks and 3-Evolution trucks and 1-ECM tanker was on site during my inspection.
1633751540 2018-06-21 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were not in operation during my inspection and it was noted that one Cleercreek tanker was on site offloading during my inspection.
1641375109 2017-09-25 Salt Water Injection Well No Violations Met well owner on site to discuss the possibility of placing more storage tanks at the site and possibly apply for Order to operate a facility to clean and store brine and other oilfield waste.
1663370848 2017-11-29 Salt Water Injection Well No Violations Inspection today indicated that all three injection pumps were in operation during my inspection.
1695615170 2019-7-24 0:00: SW No Violations
1717402096 2015-07-09 Salt Water Injection Well No Violations Inspection revealed that well was in operation today.
1737527093 2018-08-10 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were in operation today and it was noted that facility was extremely busy today.
1746595363 2018-05-15 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation during my inspection and it was noted that twenty brine trucks were on site during my inspection.
1753402116 2015-04-03 Brine Hauler No Violations On site with UIC Inspector Dave Ball, 3 Brine Trucks on site. SunPro (UIC #25-418) Labeled Properly and approved to haul to the Mozena #1, and Hall Drilling (25-361) Labeled properly but has not modified plan to haul to the Mozena #1 called Hall Drilling and requested a modification application.
1756669040 2016-07-29 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation and it was noted that one 25-564 vacuum truck was on site unloading during my inspection.
1760953633 2017-04-07 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were not in operation during my inspection.
1787708278 2014-07-07 Completion Testing No Violations On site to perform required pressure testing of casing and pump inhibitor and pressure test tubing.
1805856757 2016-05-16 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection and it was noted that three Ridge Runner vacuum trucks were unloading at the facility today.
1808500377 2017-12-18 Salt Water Injection Well No Violations Inspection today indicated that all three injection pumps were in operation during my inspection.

Note: Two Sunpro vacuum trucks were offloading at the facility during my inspection.

1808690326 2015-06-22 Preliminary Restoration No Violations Restoration work at the site is satisfactory pits have been filled in and site restored and vegetation has been established.
1816554862 2016-12-30 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were in operation during my inspection.
1855768081 2015-04-22 Salt Water Injection Well No Violations Inspection on this day indicated that both injection pumps were in operation and there was several vacuum trucks waiting to unload at the facility during my inspection.

Note: Owner has had storage tanks cleaned out and is waiting on profile of material so he can make arrangements to haul to a approved landfill.

1895994736 2019-04-24 Salt Water Injection Well No Violations Inspection revealed that injection pumps were not in operation during my inspection.

Truck audits today.

1899601043 2016-07-19 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and it was stated by operator that water disposal is pretty slow going for that past week.
1910890424 2015-10-28 Salt Water Injection Well No Violations

Inspection revealed that owner has recently graded site and applied seed & mulch to recently reclaimed ground in the area of drilling pit and also graded area where temporary storage tanks were located will check back at site at later date too see if vegetation has began to grow.

Note: Four monitoring wells have been placed on outside perimeter of storage tank area too allow for monitoring ground water in the event of tank leakage or vault leakage.
1919256328 2018-10-25 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during our inspection.

On site today to perform truck audits.

1923415522 2016-08-26 Salt Water Injection Well No Violations Inspection today revealed that injection pumps were not in operation and it was noted that one ECM Tanker was unloading at the site during my inspection.
1933946219 2017-07-06 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were not in operation during my inspection and it was noted that three Evolution vacuum trucks were unloading at the facility today.
1937560577 2018-03-05 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operationtoday and it was noted that 19 brine trucks were on site waiting to unload during my inspection.
1950136092 2015-07-09 Preliminary Restoration No Violations Restoration work at site satisfactory, pits have been filled in and site restored and vegetation has been established.
1971764894 2019-05-10 Salt Water Injection Well No Violations On site to witness MIT testing on said well they applied 1725 psi and we monitored pressure for 15 minutes with no decline in pressure(TEST PASSED).


Note bled pressure on annulus down to 500 psi once testing was completed.

1985416438 2015-07-09 Brine Hauler No Violations PERFORMED FIELD AUDIT OF BRINE TRUCKS:(1) RAMCO ENVIRONMENTAL UIC #25-591 LABELED PROPERLY BUT NOT APPROVED TO HAUL TO THE MOZENA #1. SENT EMAIL NOTIFYING THEM TO FILL OUT A MODIFICATION OF DISPOSAL PLAN APPLICATION FORM 12. (2) IBEX INCORPORATED UIC #25-522 LABELED PROPERLY BUT NOT APPROVED TO HAUL TO THE MOZENA #1 SENT LETTER REQUESTING MODIFICATION OF DISPOSAL PLAN APPLICATION FORM 12 (1) MOUNTAIN ENERGY UIC #25-514 LABELED PROPERLY AND APPROVED TO HAUL TO THE MOZENA #1 (1) ELITE GASFIELD SERVICES UIC #25-516 LABELED PROPERLY BUT NOT APPROVED TO HAUL TO THE MOZENA #1, SENT A LETTER REQUESTING MODIFICATION OF DISPOSAL PLAN APPLICATION FORM 12. (1) MYERS WELL SERVICE UIC #25-427 LABELED PROPERLY AND APPROVED TO HAUL TO THE MOZENA #1.
2015475700 2018-07-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that facility was extremely busy during my inspection.
2033900620 2019-04-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Noted four Myers trucks offloading during my inspection.

2074681583 2020-3-31 0:00: SW No Violations
2076096051 2018-09-04 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection and it was noted that contractor was starting construction of new storage tank today.
2081242459 2018-11-02 Salt Water Injection Well No Violations Inspection revealed that injection pumps were in operation during my inspection.

Note: 10,000 barrel storage tank nearly complete, contractor has to place valves and then complete plumbing work then we can hydro test tank.

2082441960 2018-01-05 Salt Water Injection Well No Violations Inspection today revealed that two injection pumps were in operation and it was noted that fluid end on pump number three has been removed and being repaired.

Note four Royal Flush trucks were offloading at the facility during my inspection.

2119462763 2017-04-20 Salt Water Injection Well No Violations Inspection today indicated that injection pumps were not in operation during my inspection and it was noted that two Myers tankers were unloading at the facility during my inspection.
245825086 2016-3-7 0:00:0 SW No Violations
252516445 2017-3-24 0:00: SW No Violations
307900257 2016-10-18 0:00 SW No Violations
358026225 2014-11-10 0:00 SW No Violations
367978733 2014-9-23 0:00: SW No Violations 2.00
373959078 2016-1-7 0:00:0 SW No Violations
377739541 2015-4-7 0:00:0 SW No Violations
424171960 2017-8-8 0:00:0 SW No Violations
429717537 2014-10-2 0:00: SW No Violations
471203664 2018-7-5 0:00:0 SW No Violations
485095522 2018-4-10 0:00: SW No Violations
505373216 2018-8-1 0:00:0 SW No Violations
513833351 2014-10-15 0:00 SW No Violations
518028283 2015-3-11 0:00: BH No Violations
539324804 2015-9-30 0:00: SW No Violations
551908148 2017-4-7 0:00:0 SW No Violations
599981279 2017-10-2 0:00: SW No Violations
600891801 2019-8-12 0:00: SW No Violations
615039157 2017-8-23 0:00: SC No Violations
722358874 2014-9-4 0:00:0 SW No Violations
726456178 2015-8-12 0:00: SW No Violations
754278943 2018-9-26 0:00: SW No Violations
814368404 2015-2-27 0:00: SW No Violations
83047851 2017-9-6 0:00:0 SW No Violations
831806840 2017-2-23 0:00: SW No Violations
920989644 2015-9-24 0:00: SW No Violations
928603875 2015-4-13 0:00: SW No Violations
970179515 2015-3-12 0:00: SW No Violations

For data sources see[4]