If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-051-24325 | | Well ID: 37-051-24325 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 39.808139, -79.390917 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 21: | Line 21: | ||
| License Status: Regulatory Inactive Status | | License Status: Regulatory Inactive Status | ||
|- | |- | ||
− | | Spud Date: 05 | + | | Spud Date: 2010-05-10 |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2010-03-05 |
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
Line 49: | Line 49: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | <!--== Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 205: | Line 230: | ||
| 1889746 | | 1889746 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2010-05-27 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 212: | Line 237: | ||
| 1958047 | | 1958047 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2011-02-18 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 219: | Line 244: | ||
| 1958051 | | 1958051 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2011-02-14 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 226: | Line 251: | ||
| 1958059 | | 1958059 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2011-02-12 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 233: | Line 258: | ||
| 1960999 | | 1960999 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2011-03-14 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 240: | Line 265: | ||
| 1961191 | | 1961191 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2011-03-07 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 247: | Line 272: | ||
| 1979334 | | 1979334 | ||
| Primary Facility | | Primary Facility | ||
− | | 06 | + | | 2011-06-09 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| Violation(s) Noted | | Violation(s) Noted | ||
Line 254: | Line 279: | ||
| 1989856 | | 1989856 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2011-07-19 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| Outstanding Violations - No Viols Req'd | | Outstanding Violations - No Viols Req'd | ||
Line 261: | Line 286: | ||
| 2006151 | | 2006151 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2011-07-06 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 268: | Line 293: | ||
| 2046964 | | 2046964 | ||
| Primary Facility | | Primary Facility | ||
− | | 02 | + | | 2012-02-15 |
| Compliance Evaluation | | Compliance Evaluation | ||
| No Violations Noted | | No Violations Noted | ||
Line 275: | Line 300: | ||
| 2092490 | | 2092490 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2012-08-16 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 282: | Line 307: | ||
| 2165182 | | 2165182 | ||
| Primary Facility | | Primary Facility | ||
− | | 05 | + | | 2013-05-09 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 289: | Line 314: | ||
| 2187997 | | 2187997 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2013-07-23 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 296: | Line 321: | ||
| 2265674 | | 2265674 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2014-04-23 |
| Site Restoration | | Site Restoration | ||
| No Violations Noted | | No Violations Noted | ||
Line 349: | Line 374: | ||
| 613113 | | 613113 | ||
| 06/09/2011 | | 06/09/2011 | ||
− | | | + | | 2011-06-09 |
| 206C - Failure to restore well site within nine months after completion of drilling, failure to remove all pits, drilling supplies and equipment not needed for production. | | 206C - Failure to restore well site within nine months after completion of drilling, failure to remove all pits, drilling supplies and equipment not needed for production. | ||
| Administrative | | Administrative | ||
Line 371: | Line 396: | ||
| Comply/Closed | | Comply/Closed | ||
| | | | ||
− | | 03 | + | | 2012-03-02 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
| style="text-align: right;" | | | style="text-align: right;" | | ||
Line 382: | Line 407: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> | ||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Pennsylvania Wells]] | [[Category:Pennsylvania Wells]] |
Well ID: 37-051-24325 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.808139,"lon":-79.390917,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Fayette | |
Municipality: Henry Clay Township | |
Operator Name: LPR ENERGY LLC | |
Well Pad ID: 146187 | |
Farm/Lease Name: BURNWORTH UNIT 1H | |
License Status: Regulatory Inactive Status | |
Spud Date: 2010-05-10 | |
Permit Date: 2010-03-05 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.808139 | |
Longitude: -79.390917 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | LPR ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | LPR ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2010-A01 | Drilling Fluid Waste (in Barrels) | 663.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010-S01 | Drilling Fluid Waste (in Barrels) | 331.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011-S01 | Drill Cuttings (in Tons) | 399.44 Tons | LANDFILL | 100081 |
2011-S01 | Drill Cuttings (in Tons) | 662.43 Tons | LANDFILL | 100172 |
2014-S02 | Fracing Fluid Waste (in Barrels) | 5,600.00 Bbl | REUSE OTHER THAN ROAD SPREADING |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1889746 | Primary Facility | 2010-05-27 | Routine/Complete Inspection | No Violations Noted | |
1958047 | Primary Facility | 2011-02-18 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, CLOSED LOOP SYSTEM WORKING GOOD .UDI # 5 CEMENTING, INTER MEDIATE CASING @ 1834'. RETURNS OF CEMENT TO SURFACE,JOB WENT GOOD. |
1958051 | Primary Facility | 2011-02-14 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, CLOSED LOOP SYSTEM WORKING GOOD. DRILLING @ 671' AT PRESENT TIME. E&S LOOKS GOOD. |
1958059 | Primary Facility | 2011-02-12 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, CLOSED LOOP SYSTEM WORKING GOOD. DRILLING @ 500' AT PRESENT TIME.EXSPECTING TO TD @ 563'.RECEIVED CALL 2/12/2011 ABOUT 10:00 PM LOST CIRCULATION PRIOR TO TD @ 563' REQURING IF THET TO USE POUR STRING. WHAT OPTIONS ARE THERE BECAUSE NO POUR STRING.RECOMMENDED 1" TUBING TO BE USED. VOID IS @ 170' -190'. TOTAL OF 340 SACKS OF CEMENT USED TO FILL VOID. RETURNS TO SURFACE TEN SACKS OF CEMENT. |
1960999 | Primary Facility | 2011-03-14 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS,CLOSE LOOP SYSTEM WORKING GOOD. TD @ 10,525' TODAY RUNNING PROD. CASING TODAY,CEMENTING TONIGHT. |
1961191 | Primary Facility | 2011-03-07 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, CLOSED LOOP SYSTEM WORKING GOOD. UDI # 5 DRILLING @ 7926'. EXSPECTING TO LAND IN MARCELLUS @ 8367'. |
1979334 | Primary Facility | 2011-06-09 | Routine/Complete Inspection | Violation(s) Noted | |
1989856 | Primary Facility | 2011-07-19 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2006151 | Primary Facility | 2011-07-06 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS, WELL SITE IN PROGRESS OF BEING RECLAIMED. |
2046964 | Primary Facility | 2012-02-15 | Compliance Evaluation | No Violations Noted | On June 9, 2011, WQS Beth Smock inspected the Burnworth site and found that the site was not restored within the required 9 months and issued a NOV to Chief for the same. Also in 2011, Chevron acquired the Burnworth site and the Chief NOV. |
2092490 | Primary Facility | 2012-08-16 | Routine/Complete Inspection | No Violations Noted | Site ID sign in place, area fenced in and gated, good vegetative growth and coverage, no other equipment on site, well was labeled. |
2165182 | Primary Facility | 2013-05-09 | Routine/Complete Inspection | No Violations Noted | Restoration work has been completed. Some areas left unmulched due to landowner request. |
2187997 | Primary Facility | 2013-07-23 | Routine/Complete Inspection | No Violations Noted | Well inactive. Reclaimation done earlier in year has good growth now. No E&S issues. |
2265674 | Primary Facility | 2014-04-23 | Site Restoration | No Violations Noted | On 4/23/2014, the Department performed an inspection of Chevron Appalachia LLC's Burnworth West Unit 1H in Henry Clay Township, Fayette County. The reason for the inspection was that the operator is requesting a Notice of Termination, (NOT), for their ESCGP#1 permit for the site. The well on site, permit # 051-24325, is on inactive status at this time. |
2474445 | Primary Facility | 2016-04-12 | Routine/Complete Inspection | No Violations Noted | ID sign at entrance. 1 well drilled but not equipped for production. No tanks. No pits. E&S ok. Inactive Status approved as per efacts. |
2694033 | Primary Facility | 2018-02-12 | Routine/Complete Inspection | No Violations Noted | Well head surrounded by security fence. The well does not appear equipped for production. The NOT associated with this site was approved on 4-23-14. According to Department records this well is in regulatory inactive status. |
2755233 | Primary Facility | 2018-07-24 | Routine/Complete Inspection | No Violations Noted | Well does not appear to be in production and does not appear to be equipped for production. Basement is wet but shows no hydrocarbon sheen. A significant pressure is noted on one annulus while another gauge shows no pressure. Unable to determine what is open and/or shut in. On site inspection shows no apparent violations. NOVIO |
2851850 | Primary Facility | 2019-03-12 | Compliance Evaluation | No Violations Noted | This well is tagged and presently under regulatory inactive status.
The well head casing looks ok. The application for inactive status was a one year extension and on the application the operator states that if the economics of building a pipeline to the Burnworth Well Pad do not support the cost of building the pipeline infrastructure then the operator will proceed with Plugging and Abandoning the well by May, 2019. An additional compliance inspection will be conducted at a later date. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1979334 | 613113 | 06/09/2011 | 2011-06-09 | 206C - Failure to restore well site within nine months after completion of drilling, failure to remove all pits, drilling supplies and equipment not needed for production. | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
613113 | 271504 | NOV - Notice of Violation | Comply/Closed | 2012-03-02 |
For data sources see[6]