X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-019-00651"

m
m
 
(2 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-019-00651
 
| Well ID: 37-019-00651
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.792361, -79.747583 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.792350, -79.747550 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Butler County, Pennsylvania|Butler]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Winfield Township, Butler County, Pennsylvania|Winfield Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Butler_County,_Pennsylvania|Butler]]
 +
|-
 +
| Municipality: [[Winfield Township,_Butler_County,_Pennsylvania|Winfield Township]]
 
|-
 
|-
 
| Operator Name: [[REDMILL DRILLING]]
 
| Operator Name: [[REDMILL DRILLING]]
Line 13: Line 17:
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: WM M CYPHER ET UX 10211
|-
 
| First Permit Date: 1856-08-15
 
 
|-
 
|-
| Last Permit Date: 1856-08-15
+
| License Status: ACTIVE
 
|-
 
|-
| Spud Date: 1800-01-01
+
| Spud Date:  
 
|-
 
|-
| Unconventional: No
+
| Permit Date:  
 
|-
 
|-
| Horizontal: No
+
| Well Type: GAS
 
|-
 
|-
| Well Status: ACTIVE
+
| Unconventional Well: N
 
|-
 
|-
| Violations: 0
+
| Configuration: Vertical Well
 
|-
 
|-
| Latitude: 40.792361
+
| Conservation: No
 
|-
 
|-
| Longitude: -79.747583
+
| Latitude: 40.792350
 
|-
 
|-
 +
| Longitude: -79.747550
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Date
!scope="col" | GAS QUANTITY
+
!scope="col" | Event
!scope="col" | GAS PRODUCTION DAYS
 
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 1991-0
+
| 1916-01-01
| style="text-align:right;" | 936.0
+
| Drilling Completion
| style="text-align:right;" | 365.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 1987-03-25
 +
| OLD WELL
 
|-
 
|-
| 1992-0
+
|}
| style="text-align:right;" | 934.0
+
For data sources see<ref>{{cite web
| style="text-align:right;" | 366.0
+
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
| style="text-align:right;" | 0.0
+
| date = 2020-02-27
| style="text-align:right;" | 0.0
+
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
| style="text-align:right;" | 0.0
+
| accessdate = 2020-02-27 }}</ref>
| style="text-align:right;" | 0.0
+
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 1995-0
+
|}-->
| style="text-align:right;" | 183.0
+
 
| style="text-align:right;" | 211.0
+
<!--== Stimulation Data ==
| style="text-align:right;" | 0.0
+
{| class="wikitable sortable" width="95%"
| style="text-align:right;" | 0.0
+
!scope="col" | Stimulation Date
| style="text-align:right;" | 0.0
+
!scope="col" | Phase Number
| style="text-align:right;" | 0.0
+
!scope="col" | Chemical Agent
|-
+
!scope="col" | Volume (gal)
|-
+
!scope="col" | Treating Pressure (psi)
| 1996-0
+
!scope="col" | Breakdown Pressure (psi)
| style="text-align:right;" | 255.0
 
| style="text-align:right;" | 365.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
|}-->
 +
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 1999-0
+
| 1990
| style="text-align:right;" | 315.0
+
| [[DAMSON OIL CORP]]
| style="text-align:right;" | 365.0
+
| style="text-align: right;" | 1010.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 1991
 +
| [[PARKER & PARSLEY DEV LP]]
 +
| style="text-align: right;" | 936.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2000-0
+
| 1992
| style="text-align:right;" | 282.0
+
| [[PARKER & PARSLEY DEV LP]]
| style="text-align:right;" | 364.0
+
| style="text-align: right;" | 934.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 366
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 1993
 +
| [[PARKER & PARSLEY DEV LP]]
 +
| style="text-align: right;" | 970.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2001-0
+
| 1994
| style="text-align:right;" | 260.0
+
| [[PARKER & PARSLEY DEV LP]]
| style="text-align:right;" | 335.0
+
| style="text-align: right;" | 637.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 1995
 +
| [[RANGE OPR CO]]
 +
| style="text-align: right;" | 135.00
 +
| style="text-align: right;" | 153
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2002-0
+
| 1996
| style="text-align:right;" | 255.87
+
| [[RANGE OPR CO]]
| style="text-align:right;" | 335.0
+
| style="text-align: right;" | 255
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 1999
 +
| [[BLX INC]]
 +
| style="text-align: right;" | 315
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2003-0
+
| 2000
| style="text-align:right;" | 250.17
+
| [[BLX INC]]
| style="text-align:right;" | 334.0
+
| style="text-align: right;" | 282
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2001
 +
| [[BLX INC]]
 +
| style="text-align: right;" | 260
 +
| style="text-align: right;" | 335
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2004-0
+
| 2002
| style="text-align:right;" | 275.52
+
| [[BLX INC]]
| style="text-align:right;" | 365.0
+
| style="text-align: right;" | 255.87
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 335
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2003
 +
| [[BLX INC]]
 +
| style="text-align: right;" | 250.17
 +
| style="text-align: right;" | 334
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2005-0
+
| 2004
| style="text-align:right;" | 273.02
+
| [[BLX INC]]
| style="text-align:right;" | 365.0
+
| style="text-align: right;" | 275.52
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2005
 +
| [[BLX INC]]
 +
| style="text-align: right;" | 273.02
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2006-0
+
| 2006
| style="text-align:right;" | 320.0
+
| [[BLX INC]]
| style="text-align:right;" | 364.0
+
| style="text-align: right;" | 320.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2007
 +
| [[BLX INC]]
 +
| style="text-align: right;" | 287.00
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2007-0
+
| 2008
| style="text-align:right;" | 287.0
+
| [[BLX INC]]
| style="text-align:right;" | 364.0
+
| style="text-align: right;" | 275.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2009
 +
| [[BLX INC]]
 +
| style="text-align: right;" | 284.00
 +
| style="text-align: right;" | 361
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2008-0
+
| 2010
| style="text-align:right;" | 275.0
+
| [[BLX INC]]
| style="text-align:right;" | 365.0
+
| style="text-align: right;" | 142.66
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 155
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2011
 +
| [[BLX INC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2009-0
+
| 2012
| style="text-align:right;" | 284.0
+
| [[BLX INC]]
| style="text-align:right;" | 361.0
+
| style="text-align: right;" | 1,658.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[REDMILL DRILLING]]
 +
| style="text-align: right;" | 1,978.46
 +
| style="text-align: right;" | 308
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-0
+
| 2014
| style="text-align:right;" | 142.66
+
| [[REDMILL DRILLING]]
| style="text-align:right;" | 155.0
+
| style="text-align: right;" | 2,427.71
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[REDMILL DRILLING]]
 +
| style="text-align: right;" | 1,809.14
 +
| style="text-align: right;" | 331
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-0
+
| 2016
| style="text-align:right;" | 0.0
+
| [[REDMILL DRILLING]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1,733.45
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[REDMILL DRILLING]]
 +
| style="text-align: right;" | 1,553.71
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-0
+
| 2018
| style="text-align:right;" | 1658.0
+
| [[REDMILL DRILLING]]
| style="text-align:right;" | 365.0
+
| style="text-align: right;" | 1,501.04
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| 2019
| 2013-0
+
| [[SME WELL SVC INC]]
| style="text-align:right;" | 1978.46
+
| style="text-align: right;" | 1,353.66
| style="text-align:right;" | 308.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
|-
 
|-
 
| 2014-0
 
| style="text-align:right;" | 2427.71
 
| style="text-align:right;" | 364.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =Oil and Gas Production Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== Waste Data ==
+
<!--== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
+
|-
!scope="col" | FACILITY CITY
+
|}-->
!scope="col" | FACILITY STATE
+
 
|}
 
For data sources see<ref>{{cite web
 
| title = Oil and Gas Historical Waste Report
 
| publisher = [[Pennsylvania Department of Environmental Protection]]
 
| date = 2015-05-26
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
 
| accessdate = 2015-05-26 }}</ref>
 
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 1924380
 
| 1924380
 +
| Primary Facility
 
| 2010-10-22
 
| 2010-10-22
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1927972
 
| 1927972
 +
| Primary Facility
 
| 2010-11-17
 
| 2010-11-17
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1931713
 
| 1931713
 +
| Primary Facility
 
| 2010-12-03
 
| 2010-12-03
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1932085
 
| 1932085
 +
| Primary Facility
 
| 2010-12-06
 
| 2010-12-06
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1932660
 
| 1932660
 +
| Primary Facility
 
| 2010-12-08
 
| 2010-12-08
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1933340
 
| 1933340
 +
| Primary Facility
 
| 2010-12-10
 
| 2010-12-10
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1934606
 
| 1934606
 +
| Primary Facility
 
| 2010-12-16
 
| 2010-12-16
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 1940682
 +
| Primary Facility
 +
| 2011-01-04
 +
| Complaint Inspection
 +
| No Violations Noted
 
|  
 
|  
|
 
|
 
|-
 
 
|-
 
|-
 
| 1941077
 
| 1941077
 +
| Primary Facility
 
| 2010-12-23
 
| 2010-12-23
 +
| Complaint Inspection
 
| Pending
 
| Pending
 
| Atmospheric free gas samples were taken with combustable gas meter for stray gas complaint.
 
| Atmospheric free gas samples were taken with combustable gas meter for stray gas complaint.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1941087
 
| 1941087
 +
| Primary Facility
 
| 2010-12-28
 
| 2010-12-28
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Free atmospheric methane was sampled for complaint investigation using a combustable gas meter.
 
| Free atmospheric methane was sampled for complaint investigation using a combustable gas meter.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1941107
 
| 1941107
 +
| Primary Facility
 
| 2010-12-30
 
| 2010-12-30
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1941114
 
| 1941114
 +
| Primary Facility
 
| 2010-01-04
 
| 2010-01-04
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Free gas samples taking while investigating complaint of stray gas.
 
| Free gas samples taking while investigating complaint of stray gas.
|
 
|
 
|
 
|-
 
|-
 
| 1940682
 
| 2011-01-04
 
| No Violations Noted
 
|
 
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1943858
 
| 1943858
 +
| Primary Facility
 
| 2011-01-06
 
| 2011-01-06
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| This inspection involved taking free atmospheric gas samples with a combustable gas meter calibrated for % methane.  80% methane in old water well, 0% methane in new water well (used) and Cypher Gas Well vent was @ 98% methane.
 
| This inspection involved taking free atmospheric gas samples with a combustable gas meter calibrated for % methane.  80% methane in old water well, 0% methane in new water well (used) and Cypher Gas Well vent was @ 98% methane.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1944522
 
| 1944522
 +
| Primary Facility
 
| 2011-01-19
 
| 2011-01-19
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Free atmospheric gas samples were taken as part of investigation of this complaint.  At the Cypher Well 1.4% methane.  0.0% at the "new" water well.  60% at the old water well.  At the time of the inspection the vent was clogged due to frozen condensation in the line.  The vent line was cut off to prevent the collection of condensation.
 
| Free atmospheric gas samples were taken as part of investigation of this complaint.  At the Cypher Well 1.4% methane.  0.0% at the "new" water well.  60% at the old water well.  At the time of the inspection the vent was clogged due to frozen condensation in the line.  The vent line was cut off to prevent the collection of condensation.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1944562
 
| 1944562
 +
| Primary Facility
 
| 2011-01-19
 
| 2011-01-19
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1944564
 
| 1944564
 +
| Primary Facility
 
| 2011-01-21
 
| 2011-01-21
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1944600
 
| 1944600
 +
| Primary Facility
 
| 2011-01-20
 
| 2011-01-20
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Inspection done as part of an on-going gas migration complaint.  Free Atmospheric Gas measurement.  0% in New Well  0% in Old Water Well.  End of plastic vent line- 0%.  Gas sample was not taken at the Cypher well head vent.  No plume was observed at well head vent.
 
| Inspection done as part of an on-going gas migration complaint.  Free Atmospheric Gas measurement.  0% in New Well  0% in Old Water Well.  End of plastic vent line- 0%.  Gas sample was not taken at the Cypher well head vent.  No plume was observed at well head vent.
 
 
 
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1945180
 
| 1945180
 +
| Primary Facility
 
| 2011-01-24
 
| 2011-01-24
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1946218
 
| 1946218
 +
| Primary Facility
 
| 2011-01-25
 
| 2011-01-25
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Stray Gas Investigation inspection:  Well vent was clogged.  Called well operator BLX to reconfigure vent in a safe yet more effective manner that prevents blockage due to freezing and/or snow blockage.  Gas samples were taken at old water well, new water well and at this gas well.  New water well 0%,  Old water well 24%, Cypher well vent 0%.methane.
 
| Stray Gas Investigation inspection:  Well vent was clogged.  Called well operator BLX to reconfigure vent in a safe yet more effective manner that prevents blockage due to freezing and/or snow blockage.  Gas samples were taken at old water well, new water well and at this gas well.  New water well 0%,  Old water well 24%, Cypher well vent 0%.methane.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1946223
 
| 1946223
 +
| Primary Facility
 
| 2011-01-13
 
| 2011-01-13
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Stray Gas complaint investigation.  Down hole work being conducted on this well to set plug and to remove stuck packer, etc...  Atmospheric methane levels as taken with the MSA Model 60. Old water well= 0%, New Water Well= 0%, Cypher gas well vent= 98% methane.
 
| Stray Gas complaint investigation.  Down hole work being conducted on this well to set plug and to remove stuck packer, etc...  Atmospheric methane levels as taken with the MSA Model 60. Old water well= 0%, New Water Well= 0%, Cypher gas well vent= 98% methane.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1946226
 
| 1946226
 +
| Primary Facility
 
| 2011-01-14
 
| 2011-01-14
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Inspection done as part of a stray gas investigation.  Service rig on site.  Well plug was set in the Cypher Well in the 3" casing.  Free atmospheric gas samples were taken at the following locations:  Old water well = 0% and New Well 0%.  No sample taken at the Cypher well due to the fact work was being performed down hole at the time of inspection.
 
| Inspection done as part of a stray gas investigation.  Service rig on site.  Well plug was set in the Cypher Well in the 3" casing.  Free atmospheric gas samples were taken at the following locations:  Old water well = 0% and New Well 0%.  No sample taken at the Cypher well due to the fact work was being performed down hole at the time of inspection.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1946608
 
| 1946608
 +
| Primary Facility
 
| 2011-01-27
 
| 2011-01-27
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
| Complaint inspection conducted as a result of an on-going complaint investigation for stray gas.  BLX personel were contacted and informed that the existing 1.5" plastic vent line that they installed was clogged again.  BLX said that they would reconfigure the vent in a safe manner and in a way that will prevent freezing/clogging.  Old water well vent was reconfigured vertically to prevent freezing.  Free gas readings taken with the MSA model 60 are as follows  Old Water Well= 0 %,  New Water Well = 0%.  New vent configuration appears to be working.
+
| Complaint inspection conducted as a result of an on-going complaint investigation for stray gas.  BLX personel were contacted and informed that the existing 1.5" plastic vent line that they installed was clogged again.  BLX said that they would reconfigure the vent in a safe manner and in a way that will prevent freezing/clogging.  Old water well vent was reconfigured vertically to prevent freezing.  Free gas readings taken with the MSA model 60 are as follows  Old Water Well= 0 %,  New Water Well = 0%.  New vent configuration appears to be working.
 
 
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1946623
 
| 1946623
 +
| Primary Facility
 
| 2011-01-26
 
| 2011-01-26
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Inspection was done as part of an on-going complaint investigation.  BLX staff were contacted and informed that the vent line on the old Crytzer water well was plugged.  The 1.5" line was most likely clogged by frozen condensation.  Free Atmospheric gas readings are as follows.  Old water well= 54%,  New Water Well 0%, Old water well vent 0%.
 
| Inspection was done as part of an on-going complaint investigation.  BLX staff were contacted and informed that the vent line on the old Crytzer water well was plugged.  The 1.5" line was most likely clogged by frozen condensation.  Free Atmospheric gas readings are as follows.  Old water well= 54%,  New Water Well 0%, Old water well vent 0%.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1946629
 
| 1946629
 +
| Primary Facility
 
| 2011-01-31
 
| 2011-01-31
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| This inspection was done as part of a on-going stray gas investigation.  New vertical vent in place on well head.  Y was installed by operator to make sampling easier.  Atmospheric Free Gas reading were:  Old water well= 0%, New Water Well= 0% and Cypher Well vent 2 %.
 
| This inspection was done as part of a on-going stray gas investigation.  New vertical vent in place on well head.  Y was installed by operator to make sampling easier.  Atmospheric Free Gas reading were:  Old water well= 0%, New Water Well= 0% and Cypher Well vent 2 %.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1952294
 
| 1952294
 +
| Primary Facility
 
| 2011-02-23
 
| 2011-02-23
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1952295
 
| 1952295
 +
| Primary Facility
 
| 2011-02-24
 
| 2011-02-24
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1955419
 
| 1955419
 +
| Primary Facility
 
| 2011-02-08
 
| 2011-02-08
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Gas migration complaint investigation.  Used a MSA model 60 combustible gas meter to measure free atmospheric methane in:  Old Water Well= 0.0% methane  New  Water Well= 0.0% methane.
 
| Gas migration complaint investigation.  Used a MSA model 60 combustible gas meter to measure free atmospheric methane in:  Old Water Well= 0.0% methane  New  Water Well= 0.0% methane.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1955420
 
| 1955420
 +
| Primary Facility
 
| 2011-02-08
 
| 2011-02-08
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Performed pre-disturbance inspection on ESCGP-1 for this site.  Reviewed E&S plan which was adaquate.  Perimeter E&S control with all filter sock and R4 rocked channels .  Future site of 5 wells including Voll 3H.  Total disturbance area is 21.14.
 
| Performed pre-disturbance inspection on ESCGP-1 for this site.  Reviewed E&S plan which was adaquate.  Perimeter E&S control with all filter sock and R4 rocked channels .  Future site of 5 wells including Voll 3H.  Total disturbance area is 21.14.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1956674
 
| 1956674
 +
| Primary Facility
 
| 2011-02-09
 
| 2011-02-09
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Complaint Inspection performed.  Took atmospheric methane samples with MSA 60.
 
| Complaint Inspection performed.  Took atmospheric methane samples with MSA 60.
Old water well 0%,  New Water Well 0%.
 
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1956678
 
| 1956678
 +
| Primary Facility
 
| 2011-03-11
 
| 2011-03-11
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Inspection was done as follow-up to inspection 274631.  Took free atmospheric methane samples with MSA Model 60.  Old Water Well Sample - Fluctuating reading between 10-15% methane.  New Water Well= 0% methane.
 
| Inspection was done as follow-up to inspection 274631.  Took free atmospheric methane samples with MSA Model 60.  Old Water Well Sample - Fluctuating reading between 10-15% methane.  New Water Well= 0% methane.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1956688
 
| 1956688
 +
| Primary Facility
 
| 2011-02-15
 
| 2011-02-15
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| Inspection was conducted as part of a continuing stray gas investigation.  Atmospheric free methane samples were taken  with the MSA Model 60 Combustable Gas Meter.  Readings were as follows:  Old Water Well= 0% methane.  New Water Well= 0 % methane.
 
| Inspection was conducted as part of a continuing stray gas investigation.  Atmospheric free methane samples were taken  with the MSA Model 60 Combustable Gas Meter.  Readings were as follows:  Old Water Well= 0% methane.  New Water Well= 0 % methane.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1963626
 
| 1963626
 +
| Primary Facility
 
| 2011-04-06
 
| 2011-04-06
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1965280
 
| 1965280
 +
| Primary Facility
 
| 2011-04-13
 
| 2011-04-13
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1972142
 
| 1972142
 +
| Primary Facility
 
| 2011-05-11
 
| 2011-05-11
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1972608
 
| 1972608
 +
| Primary Facility
 
| 2011-05-13
 
| 2011-05-13
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1973386
 
| 1973386
 +
| Primary Facility
 
| 2011-05-17
 
| 2011-05-17
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1974359
 
| 1974359
 +
| Primary Facility
 
| 2011-05-17
 
| 2011-05-17
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1975322
 
| 1975322
 +
| Primary Facility
 
| 2011-05-23
 
| 2011-05-23
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1977346
 
| 1977346
 +
| Primary Facility
 
| 2011-06-02
 
| 2011-06-02
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 1984994
 
| 1984994
 +
| Primary Facility
 
| 2011-07-01
 
| 2011-07-01
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1997000
 
| 1997000
 +
| Primary Facility
 
| 2011-08-18
 
| 2011-08-18
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2063163
 
| 2063163
 +
| Primary Facility
 
| 2012-04-20
 
| 2012-04-20
 +
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|  
+
|-
|  
+
| 2731665
|  
+
| Primary Facility
 +
| 2018-05-16
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| At the time of inspection, well was producing.  Well integrity appeared to be in good condition, with no signs of any leaks or spills.  Well was painted and no rust was noticed.  The well was properly labeled.  The well had 4 7/8" inside of what appears to be 7" casing.  The well had a long drip hooked up, as well as a small meter, heater, and chart.  There was a strong smell of gas at the well, but I wasn't able to determine the exact location it was coming from.  Production was reported in 2017 as 1553 mcf for 365 days.
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =Oil and Gas Compliance Report
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-05-20
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]

Latest revision as of 17:40, 21 May 2020

Well Details

Well ID: 37-019-00651
Loading map...
Country: United States
State: Pennsylvania
County: Butler
Municipality: Winfield Township
Operator Name: REDMILL DRILLING
Well Pad ID:
Farm/Lease Name: WM M CYPHER ET UX 10211
License Status: ACTIVE
Spud Date:
Permit Date:
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.792350
Longitude: -79.747550

For data sources see[1][2][3]

Well History

Date Event
1916-01-01 Drilling Completion
1987-03-25 OLD WELL

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1990 DAMSON OIL CORP 1010.00 365 0.00 0 0.00 0
1991 PARKER & PARSLEY DEV LP 936.00 365 0.00 0 0.00 0
1992 PARKER & PARSLEY DEV LP 934.00 366 0.00 0 0.00 0
1993 PARKER & PARSLEY DEV LP 970.00 365 0.00 0 0.00 0
1994 PARKER & PARSLEY DEV LP 637.00 365 0.00 0 0.00 0
1995 RANGE OPR CO 135.00 153 0.00 0 0.00 0
1996 RANGE OPR CO 255 365 0.00 0 0.00 0
1999 BLX INC 315 365 0.00 0 0.00 0
2000 BLX INC 282 364 0.00 0 0.00 0
2001 BLX INC 260 335 0.00 0 0.00 0
2002 BLX INC 255.87 335 0.00 0 0.00 0
2003 BLX INC 250.17 334 0.00 0 0.00 0
2004 BLX INC 275.52 365 0.00 0 0.00 0
2005 BLX INC 273.02 365 0.00 0 0.00 0
2006 BLX INC 320.00 364 0.00 0 0.00 0
2007 BLX INC 287.00 364 0.00 0 0.00 0
2008 BLX INC 275.00 365 0.00 0 0.00 0
2009 BLX INC 284.00 361 0.00 0 0.00 0
2010 BLX INC 142.66 155 0.00 0 0.00 0
2011 BLX INC 0.00 0 0.00 0 0.00 0
2012 BLX INC 1,658.00 365 0.00 0 0.00 0
2013 REDMILL DRILLING 1,978.46 308 0.00 0 0.00 0
2014 REDMILL DRILLING 2,427.71 364 0.00 0 0.00 0
2015 REDMILL DRILLING 1,809.14 331 0.00 0 0.00 0
2016 REDMILL DRILLING 1,733.45 364 0.00 0 0.00 0
2017 REDMILL DRILLING 1,553.71 365 0.00 0 0.00 0
2018 REDMILL DRILLING 1,501.04 365 0.00 0 0.00 0
2019 SME WELL SVC INC 1,353.66 365 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1924380 Primary Facility 2010-10-22 Complaint Inspection No Violations Noted
1927972 Primary Facility 2010-11-17 Routine/Complete Inspection No Violations Noted
1931713 Primary Facility 2010-12-03 Complaint Inspection No Violations Noted
1932085 Primary Facility 2010-12-06 Complaint Inspection No Violations Noted
1932660 Primary Facility 2010-12-08 Complaint Inspection No Violations Noted
1933340 Primary Facility 2010-12-10 Complaint Inspection No Violations Noted
1934606 Primary Facility 2010-12-16 Complaint Inspection No Violations Noted
1940682 Primary Facility 2011-01-04 Complaint Inspection No Violations Noted
1941077 Primary Facility 2010-12-23 Complaint Inspection Pending Atmospheric free gas samples were taken with combustable gas meter for stray gas complaint.
1941087 Primary Facility 2010-12-28 Complaint Inspection No Violations Noted Free atmospheric methane was sampled for complaint investigation using a combustable gas meter.
1941107 Primary Facility 2010-12-30 Complaint Inspection No Violations Noted
1941114 Primary Facility 2010-01-04 Complaint Inspection No Violations Noted Free gas samples taking while investigating complaint of stray gas.
1943858 Primary Facility 2011-01-06 Complaint Inspection No Violations Noted This inspection involved taking free atmospheric gas samples with a combustable gas meter calibrated for % methane. 80% methane in old water well, 0% methane in new water well (used) and Cypher Gas Well vent was @ 98% methane.
1944522 Primary Facility 2011-01-19 Complaint Inspection No Violations Noted Free atmospheric gas samples were taken as part of investigation of this complaint. At the Cypher Well 1.4% methane. 0.0% at the "new" water well. 60% at the old water well. At the time of the inspection the vent was clogged due to frozen condensation in the line. The vent line was cut off to prevent the collection of condensation.
1944562 Primary Facility 2011-01-19 Complaint Inspection No Violations Noted
1944564 Primary Facility 2011-01-21 Complaint Inspection No Violations Noted
1944600 Primary Facility 2011-01-20 Complaint Inspection No Violations Noted Inspection done as part of an on-going gas migration complaint. Free Atmospheric Gas measurement. 0% in New Well 0% in Old Water Well. End of plastic vent line- 0%. Gas sample was not taken at the Cypher well head vent. No plume was observed at well head vent.
1945180 Primary Facility 2011-01-24 Complaint Inspection No Violations Noted
1946218 Primary Facility 2011-01-25 Complaint Inspection No Violations Noted Stray Gas Investigation inspection: Well vent was clogged. Called well operator BLX to reconfigure vent in a safe yet more effective manner that prevents blockage due to freezing and/or snow blockage. Gas samples were taken at old water well, new water well and at this gas well. New water well 0%, Old water well 24%, Cypher well vent 0%.methane.
1946223 Primary Facility 2011-01-13 Complaint Inspection No Violations Noted Stray Gas complaint investigation. Down hole work being conducted on this well to set plug and to remove stuck packer, etc... Atmospheric methane levels as taken with the MSA Model 60. Old water well= 0%, New Water Well= 0%, Cypher gas well vent= 98% methane.
1946226 Primary Facility 2011-01-14 Complaint Inspection No Violations Noted Inspection done as part of a stray gas investigation. Service rig on site. Well plug was set in the Cypher Well in the 3" casing. Free atmospheric gas samples were taken at the following locations: Old water well = 0% and New Well 0%. No sample taken at the Cypher well due to the fact work was being performed down hole at the time of inspection.
1946608 Primary Facility 2011-01-27 Complaint Inspection No Violations Noted Complaint inspection conducted as a result of an on-going complaint investigation for stray gas. BLX personel were contacted and informed that the existing 1.5" plastic vent line that they installed was clogged again. BLX said that they would reconfigure the vent in a safe manner and in a way that will prevent freezing/clogging. Old water well vent was reconfigured vertically to prevent freezing. Free gas readings taken with the MSA model 60 are as follows Old Water Well= 0 %, New Water Well = 0%. New vent configuration appears to be working.
1946623 Primary Facility 2011-01-26 Complaint Inspection No Violations Noted Inspection was done as part of an on-going complaint investigation. BLX staff were contacted and informed that the vent line on the old Crytzer water well was plugged. The 1.5" line was most likely clogged by frozen condensation. Free Atmospheric gas readings are as follows. Old water well= 54%, New Water Well 0%, Old water well vent 0%.
1946629 Primary Facility 2011-01-31 Complaint Inspection No Violations Noted This inspection was done as part of a on-going stray gas investigation. New vertical vent in place on well head. Y was installed by operator to make sampling easier. Atmospheric Free Gas reading were: Old water well= 0%, New Water Well= 0% and Cypher Well vent 2 %.
1952294 Primary Facility 2011-02-23 Complaint Inspection No Violations Noted
1952295 Primary Facility 2011-02-24 Complaint Inspection No Violations Noted
1955419 Primary Facility 2011-02-08 Complaint Inspection No Violations Noted Gas migration complaint investigation. Used a MSA model 60 combustible gas meter to measure free atmospheric methane in: Old Water Well= 0.0% methane New Water Well= 0.0% methane.
1955420 Primary Facility 2011-02-08 Routine/Complete Inspection No Violations Noted Performed pre-disturbance inspection on ESCGP-1 for this site. Reviewed E&S plan which was adaquate. Perimeter E&S control with all filter sock and R4 rocked channels . Future site of 5 wells including Voll 3H. Total disturbance area is 21.14.
1956674 Primary Facility 2011-02-09 Complaint Inspection No Violations Noted Complaint Inspection performed. Took atmospheric methane samples with MSA 60.
1956678 Primary Facility 2011-03-11 Complaint Inspection No Violations Noted Inspection was done as follow-up to inspection 274631. Took free atmospheric methane samples with MSA Model 60. Old Water Well Sample - Fluctuating reading between 10-15% methane. New Water Well= 0% methane.
1956688 Primary Facility 2011-02-15 Routine/Complete Inspection No Violations Noted Inspection was conducted as part of a continuing stray gas investigation. Atmospheric free methane samples were taken with the MSA Model 60 Combustable Gas Meter. Readings were as follows: Old Water Well= 0% methane. New Water Well= 0 % methane.
1963626 Primary Facility 2011-04-06 Complaint Inspection No Violations Noted
1965280 Primary Facility 2011-04-13 Complaint Inspection No Violations Noted
1972142 Primary Facility 2011-05-11 Complaint Inspection No Violations Noted
1972608 Primary Facility 2011-05-13 Complaint Inspection No Violations Noted
1973386 Primary Facility 2011-05-17 Complaint Inspection No Violations Noted
1974359 Primary Facility 2011-05-17 Complaint Inspection No Violations Noted
1975322 Primary Facility 2011-05-23 Complaint Inspection No Violations Noted
1977346 Primary Facility 2011-06-02 Complaint Inspection No Violations Noted
1984994 Primary Facility 2011-07-01 Complaint Inspection No Violations Noted
1997000 Primary Facility 2011-08-18 Drilling/Alteration No Violations Noted
2063163 Primary Facility 2012-04-20 Routine/Partial Inspection No Violations Noted
2731665 Primary Facility 2018-05-16 Routine/Partial Inspection No Violations Noted At the time of inspection, well was producing. Well integrity appeared to be in good condition, with no signs of any leaks or spills. Well was painted and no rust was noticed. The well was properly labeled. The well had 4 7/8" inside of what appears to be 7" casing. The well had a long drip hooked up, as well as a small meter, heater, and chart. There was a strong smell of gas at the well, but I wasn't able to determine the exact location it was coming from. Production was reported in 2017 as 1553 mcf for 365 days.