If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-20677 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.9,"lon":-81.66,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Baughman Township | |
Operator Name: DOMINION EAST OHIO | |
Well Pad ID: | |
Farm/Lease Name: GEISER FREDERICK | |
License Status: Storage Well | |
License Date: 1957-12-06 | |
Spud Date: 1957-12-07 | |
Spud Drilling Contractor: | |
Final Drill Date: 1958-02-12 | |
Well Total Depth: 3870.00 ft | |
Configuration: Vertical | |
Latitude: 40.900000 | |
Longitude: -81.660000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1957-12-07 | GL=1032.1, STORAGE |
Completed | 1958-02-12 | GL=1032.1, STORAGE |
Reached Total Depth | 1958-02-12 | GL=1032.1, STORAGE |
Record Last Modified | 2009-12-11 | GL=1032.1, STORAGE |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | R.P. 90 HRS. |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2003 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2004 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2005 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2006 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2007 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2008 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | DOMINION EAST OHIO | Brine | 0 | 0 |
2003 | DOMINION EAST OHIO | Brine | 0 | 0 |
2004 | DOMINION EAST OHIO | Brine | 0 | 0 |
2005 | DOMINION EAST OHIO | Brine | 0 | 0 |
2006 | DOMINION EAST OHIO | Brine | 0 | 0 |
2007 | DOMINION EAST OHIO | Brine | 0 | 0 |
2008 | DOMINION EAST OHIO | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-114315467 | 2018-1-18 0:00: | SO | No Violations | |
-1449680039 | 2015-1-22 0:00: | SO | No Violations | 0.50 |
-1838347861 | 2013-4-15 0:00: | SO | No Violations | |
-550714054 | 2017-2-6 0:00:0 | SO | No Violations | |
0114315467 | 2018-01-18 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohio Storage Well #2075 on 01/18/2018. The well is equipped with a flanged wellhead with 1-master valve and 2-wing valves, and 1-meter with 2-regulators and 1-100 bbl steel tank, located within an earthen dike. Well identification is clearly displayed. No problems were noted at the time of the inspection. |
0550714054 | 2017-02-06 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohios Storage Well #2075 on 02/06/2017. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and 1-meter and 1-100 bbl steel tank, located within an earthen dike. Well identification is clearly displayed. A small gas leak was noted at the wing valve. Phil Zbasnik with Dominion East Ohio was notified of this issue and will have it addressed by field staff promptly. No other problems were noted at the time of the inspection. |
0991683969 | 2019-01-22 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohio Storage Well #2075 on 01/22/2019 with Inspector Ashley Raff. The well is equipped with a flanged wellhead with 1-master valve and 2-wing valves, and 1-meter with 2-regulators and 1-100 bbl steel tank, located within an earthen dike. Well identification is clearly displayed. A locked security chain around the master valve and one wing valve was present at the time of the inspection. No problems were noted at the time of the inspection. |
1449680039 | 2015-01-22 | Storage Well | No Violations | This gas storage facility has no evident problems at this time. |
1838347861 | 2013-04-15 | Storage Well | No Violations | I inspected Dominion East Ohio Gas storage well #2075 today. The well is located in Section 36, Chippewa Township, Wayne County, Ohio. The well is equipped with a master gate valve and a side gate valve with a 4.00 Daniels run plumbed directly into the main pipeline. There is a flow gate valve with a 3.00 line plumbed into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. The storage tank is surrounded by a 2.00 dike and it is of sufficient size to meet the standards of 1501-9-9-05. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. No violations found. |
1944558669 | 2014-02-20 | Storage Well | No Violations | This storage well has no apparent problems at time of inspection. |
828528712 | 2020-1-23 0:00: | SO | No Violations | |
991683969 | 2019-1-22 0:00: | SO | No Violations |
For data sources see[8]