34-151-23401

Well Details

Well ID: 34-151-23401
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Canton Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: DEHOFF H
License Status: Producing
License Date: 1980-12-02
Spud Date: 1981-08-14
Spud Drilling Contractor:
Final Drill Date: 1981-08-20
Well Total Depth: 4825.00 ft
Configuration: Vertical
Latitude: 40.750000
Longitude: -81.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-12-02 182 BELDEN & BLAKE CO GeoDate 12/2/80
Oil and Gas 1980-12-02 Issued Date 12/2/80 Expired Date Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1981-08-14 LOG TYPE=HI
Completed 1981-08-20 LOG TYPE=HI
Reached Total Depth 1981-08-20 LOG TYPE=HI
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
Record Last Modified 2013-10-03 LOG TYPE=HI

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4630 4717 21
4630 4717 21
4630 4717 21

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 86500 Gal 50000
N2 0 180 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION 22501.00 105.00 0
1985 BELDEN & BLAKE CORPORATION 28447.00 119.00 0
1986 BELDEN & BLAKE CORPORATION 18422.00 80.00 365
1987 BELDEN & BLAKE CORPORATION 21280.00 95.00 365
1988 BELDEN & BLAKE CORPORATION 14755.00 89.00 153
1990 BELDEN & BLAKE CORPORATION 21526.00 97.00 356
1991 BELDEN & BLAKE CORPORATION 18499.00 139.00 365
1992 BELDEN & BLAKE CORPORATION 19566.00 0.00 362
1993 BELDEN & BLAKE CORPORATION 14517.00 97.00 365
1994 BELDEN & BLAKE CORPORATION 16172.00 93.00 365
1995 BELDEN & BLAKE CORPORATION 16699.00 0.00 351
1996 BELDEN & BLAKE CORPORATION 18306.00 103.00 366
1997 BELDEN & BLAKE CORPORATION 9587.00 0.00 351
1998 BELDEN & BLAKE CORPORATION 12087.00 75.00 365
1999 BELDEN & BLAKE CORPORATION 10067.00 33.00 358
2000 BELDEN & BLAKE CORPORATION 9718.00 14.00 359
2001 BELDEN & BLAKE CORPORATION 8488.00 44.00 365
2002 BELDEN & BLAKE CORPORATION 8056.00 0.00 365
2003 BELDEN & BLAKE CORPORATION 6202.00 47.00 365
2004 BELDEN & BLAKE CORPORATION 6983.00 24.00 364
2005 BELDEN & BLAKE CORPORATION 6869.00 33.00 359
2006 BELDEN & BLAKE CORPORATION 6748.00 0.00 359
2007 ENERVEST OPERATING LLC 5604.00 69.00 365
2008 ENERVEST OPERATING LLC 5718.00 1.00 365
2009 ENERVEST OPERATING LLC 5301.00 0.00 365
2010 ENERVEST OPERATING LLC 4992.00 28.00 365
2011 ENERVEST OPERATING LLC 4749.00 0.00 0
2012 ENERVEST OPERATING LLC 3903.00 24.00 366
2013 ENERVEST OPERATING LLC 3890.00 0.00 365
2014 ENERVEST OPERATING LLC 3699.00 0.00 365
2015 ENERVEST OPERATING LLC 3470.00 0.00 365
2016 ENERVEST OPERATING LLC 3375.00 27.00 366
2017 ENERVEST OPERATING LLC 2663.00 0.00 365
2018 ENERVEST OPERATING LLC 2723.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION Brine 0 0
1985 BELDEN & BLAKE CORPORATION Brine 106 0
1986 BELDEN & BLAKE CORPORATION Brine 34 365
1987 BELDEN & BLAKE CORPORATION Brine 24 365
1988 BELDEN & BLAKE CORPORATION Brine 42 153
1990 BELDEN & BLAKE CORPORATION Brine 51 356
1991 BELDEN & BLAKE CORPORATION Brine 103 365
1992 BELDEN & BLAKE CORPORATION Brine 44 362
1993 BELDEN & BLAKE CORPORATION Brine 59 365
1994 BELDEN & BLAKE CORPORATION Brine 76 365
1995 BELDEN & BLAKE CORPORATION Brine 23 351
1996 BELDEN & BLAKE CORPORATION Brine 73 366
1997 BELDEN & BLAKE CORPORATION Brine 31 351
1998 BELDEN & BLAKE CORPORATION Brine 30 365
1999 BELDEN & BLAKE CORPORATION Brine 25 358
2000 BELDEN & BLAKE CORPORATION Brine 51 359
2001 BELDEN & BLAKE CORPORATION Brine 36 365
2002 BELDEN & BLAKE CORPORATION Brine 22 365
2003 BELDEN & BLAKE CORPORATION Brine 5 365
2004 BELDEN & BLAKE CORPORATION Brine 84 364
2005 BELDEN & BLAKE CORPORATION Brine 39 359
2006 BELDEN & BLAKE CORPORATION Brine 22 359
2007 ENERVEST OPERATING LLC Brine 45 365
2008 ENERVEST OPERATING LLC Brine 3 365
2009 ENERVEST OPERATING LLC Brine 0 365
2010 ENERVEST OPERATING LLC Brine 19 365
2011 ENERVEST OPERATING LLC Brine 0
2012 ENERVEST OPERATING LLC Brine 7 366
2013 ENERVEST OPERATING LLC Brine 0 365
2014 ENERVEST OPERATING LLC Brine 0 365
2015 ENERVEST OPERATING LLC Brine 0 365
2016 ENERVEST OPERATING LLC Brine 0 366
2017 ENERVEST OPERATING LLC Brine 0 365
2018 ENERVEST OPERATING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1304409014 2018-8-9 0:00:0 PW No Violations 0.50
-603699274 2014-9-24 0:00: PW No Violations 2.00
0603699274 2014-09-24 Production Wells No Violations I was on location to follow up on complaint #4802 regarding black in the water well and tremors at a home located at 1517 Mattie Street SE, Canton, Ohio. The tank battery contains a 210bbl production tank, brine vault, vertical separator and an ID sign. The well is a plunger lift well with no gauges to measure pressure. The 8.625 diameter casing is buried and has a 2 diameter riser pipe to surface. There is no gas flow or pressure on the 2 riser from the 8.625 wellhead. The well and the tank battery are in good condition and appear to have no mechanical issues.
1304409014 2018-08-09 Production Wells No Violations I did a status check inspection on this well. The well is equipped with a casing plunger-lift system. The tank battery consists of a steel production tank, an inground concrete brine vault, a horizontal separator and a meter. The well is legibly identified. No compliance issues are noted at this time.
1320635260 2011-11-04 Production Wells No Violations I received a call on 11-4-11 from Deb Moore of the Stark County Health Department (330-493-9904, extension 260) regarding a water well investigation she is conducting for Glen Sheats and Helen Stevens who live at 1701 Mattie St., Canton, OH 44707. The water well tested negative for bacteria and negative for VOCs. The Health Department does not test for methane and she would like ODNR to test for methane. The home owners told her that they saw gas bubbling around the casing of the oil and gas well over a year ago. Not long after that they started to see effervesence in their well water and became concerned. I met with Tim McConaha (Enervest) and the property owners and inspected the oil and gas well. There was no evidence of gas leaking at the wellhead. I requested that Enervest dig up and expose the buried 8.625 wellhead so we can check for any gas leaks. This will be done on Tuesday 11-8-11. The water well is located approximately 350 north and upgradient from the oil and gas well. I went into the basement of the house with the home owners to do a visual inspection of the their water. The water is highly effervesent, turns clear in less than 1 minute when put into a glass, and has no petroleum odor. There was no evidence of oil residue in the toilet tank or in the sink. I will investigate the buried oil and gas wellhead for any leaks and I will ask Kyle Tharp to contact Deb Moore about sampling the water well for methane.
1320885840 2011-11-08 Production Wells No Violations Hawkins Well Service excavated around the 8.625 wellhead. There was no gas leaking from the wellhead, but there was some oil staining in the excavated soil. This is normal for wells that have been in production for many years. Hawkins Well Service installed a 2 dia riser pipe from the 8-5/8 dia wellhead to 2 above ground level for future monitoring of gas. The excavation was backfilled and leveled. Glen Sheats, Helen Stevens, Charlie Youngen (Enervest), and I observed the excavation process. I walked up gradient from the oil and gas well and took a GPS (40.75986, 81.35888) on the water well.
1608059990 2015-03-10 Production Wells No Violations I was on location to follow up to complaint #4957 regarding natural gas venting from a domestic water well. The lease road is stable and does not show signs of erosion. The tank battery is contained within a dike and has proper I.D. signage. The tank battery contains a 210bbl production tank, vertical separator and concrete brine vault. The well is a concoyle well with a riser tube from the 8.625 diameter surface casing. There is no pressure or venting from the annulus. The well is in good mechanical condition and there are no violations at this time.

For data sources see[9]