34-119-23056

Well Details

Well ID: 34-119-23056
Loading map...
Country: United States
State: Ohio
County: Muskingum
Municipality: Rich Hill Township
Operator Name: WATSON DANA L
Well Pad ID:
Farm/Lease Name: WATSON
License Status: Final Restoration
License Date: 2015-12-15
Spud Date: 1973-04-24
Spud Drilling Contractor: PERKINS DRLG
Final Drill Date: 1973-04-29
Well Total Depth: 4988.00 ft
Configuration: Vertical
Latitude: 39.860000
Longitude: -81.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1973-04-24 UPDATED WELL LOCATION PER SURVEYOR'S COORDINATES ALE 03/29/2017.
Completed 1973-04-29 UPDATED WELL LOCATION PER SURVEYOR'S COORDINATES ALE 03/29/2017.
Reached Total Depth 1973-04-29 UPDATED WELL LOCATION PER SURVEYOR'S COORDINATES ALE 03/29/2017.
Completion Report Received 1973-07-02 UPDATED WELL LOCATION PER SURVEYOR'S COORDINATES ALE 03/29/2017.
CO 1982-02-01 628 WALDRON DAVID A GeoDate 2/1/82
CO 1989-06-13 3441 WATSON DANA L GeoDate 6/13/89
Unknown 1989-06-13 Issued Date 6/13/89 Expired Date 6/13/90 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
APP 2015-12-15 Proposed Formations:CLINTON, Issued Date:12/15/2015, Expired Date:12/14/2017 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2015-12-29 UPDATED WELL LOCATION PER SURVEYOR'S COORDINATES ALE 03/29/2017.
Record Last Modified 2017-03-29 UPDATED WELL LOCATION PER SURVEYOR'S COORDINATES ALE 03/29/2017.
Construction Permit Expires 2017-12-14 UPDATED WELL LOCATION PER SURVEYOR'S COORDINATES ALE 03/29/2017.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2002-11-22 4805 4837 13
4805 4837 13
4805 4837 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1405 Bbl 52500

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 CAVENDISH PETRO OF OH INC 9443.00 0.00 0
1985 CAVENDISH PETRO OF OH INC 4878.00 0.00 365
1988 WALDRON DAVID A 0.00 0.00 365
1989 WALDRON DAVID A 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 CAVENDISH PETRO OF OH INC Brine 0 0
1985 CAVENDISH PETRO OF OH INC Brine 12 365
1988 WALDRON DAVID A Brine 15 365
1989 WALDRON DAVID A Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-280000979 2017-1-4 0:00:0 FR No Violations 1.00
-457973872 2003-6-12 0:00: PW No Violations
-745088189 2016-1-25 0:00: PB No Violations 4.00
0280000979 2017-01-04 Final Restoration No Violations Final Restoration passed on 1-4-17 by Patrick Shreve. Well was plugged in compliance OAC 1501-9-11. The land was restored back under ORC 1509.072. Weather is cold, windy and clear. The temperature is 31 degrees Fahrenheit and there is no snow on the ground.
0457973872 2003-06-12 Production Wells No Violations
0745088189 2016-01-25 Plug / Plug Back No Violations I met with Brian Jasper on well 119-23056. The well plugged. He had talked about the water tickets and his obligation with State and the Paperwork. He would remove the 210 barrel steel tank when the weather warrants.
0820369606 2016-08-04 Final Restoration No Violations The purpose of my inspection was a Final Restoration that did not pass. I met with Brian Jasper of Formation Cementing on the permit number 119-2-3056. He stated that Altier Bros. were supposed to come back and remove the 210 barrel steel tank and the vertical separator. They were supposed to clean up the piping laying on the ground. He said he will take care of the issue and have removed.
0961330254 2015-11-03 Production Wells Violations Noted Well is shut in and not producing. Well is equipped with a gas plunger lift system. The tubing annulus is shut with no pressure. The tubing valve is shut in. The well is not hooked up to the flow lines at all. There is 1-210 barrel steel tank and the meter has been removed from the flow line. There is no identification. Well has watered out and is not capable. The well owner /operator shall submit a written plugging schedule to Patrick Shreve at 5880 Memory Rd. Zanesville, Ohio 43701 within 30 days per OAC 1501:9-11-05(B) and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
1125174246 2017-01-20 Final Restoration No Violations The Final Restoration has been completed on this well site. Tom Smith and I inspector Patrick Shreve visited site to locate the well casing with the Ga-52CX unit and then Tom used the Trimble and shot an accurate coordinate for the file. The Final Restoration was passed on 1-4-2017 by Patrick Shreve.
1203106713 2008-02-15 Production Wells No Violations Domestic well. Producing, no problems noted
1369297886 2015-08-27 Exempt Well Pre Transfer No Violations The well is a gas plunger lift system that is shut in and not capable. The well is loaded up with brine. There is a 210 barrel steel tank with no dike or identification. The well owner has hooked up to a gas line that runs in front of the house. The house is not hooked up to the well at all. Well does not meet the criteria listed under the R.C. 1509.01 for the definition of the Exempt Domestic wells.
1450731870 2015-12-21 Plug / Plug Back No Violations

-30---

1451938933 2015-12-29 Plug / Plug Back No Violations

---

1493815449 2015-12-29 Plug / Plug Back No Violations Well was plugged in compliance OAC 1501-9-11. This resolves the Compliance Notice Number 961330254.
820369606 2016-8-4 0:00:0 FR No Violations 2.00
961330254 2015-11-3 0:00: PW No Violations 2.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0961330254 US-OH-130999 2017-05-26 9-9-05(A)10 Failure to legibly identify well
0961330254 US-OH-131000 2017-05-26 NONE Well shall be plugged

For data sources see[9]