34-115-21462

Well Details

Well ID: 34-115-21462
Loading map...
Country: United States
State: Ohio
County: Morgan
Municipality: Center Township
Operator Name: TRIAD HUNTER LLC
Well Pad ID:
Farm/Lease Name: REMLEIGH JAMES & JOAN
License Status: Final Restoration
License Date: 2015-05-11
Spud Date: 1976-03-03
Spud Drilling Contractor:
Final Drill Date: 1976-03-10
Well Total Depth: 1780.00 ft
Configuration: Vertical
Latitude: 39.600000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1801-01-02 171 LYDIC W J INC
Original Spud 1976-03-03 I.P. NONE RPT.
Completed 1976-03-10 I.P. NONE RPT.
Reached Total Depth 1976-03-10 I.P. NONE RPT.
Completion Report Received 1976-03-18 I.P. NONE RPT.
Change of Owner 1998-12-29 Operator changed from 171, LYDIC W J INC to 1, HOPEWELL OIL & GAS
Change of Owner 2004-03-12 Operator changed from 1, HOPEWELL OIL & GAS to 2348, TRIAD RESOURCES INC
APP 2009-07-17 Proposed Formations:BEREA, Issued Date:7/17/2009, Expired Date:7/17/2010 6:00:00 AM, Drilling unit acres:225, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2010-03-24 Operator changed from 2348, TRIAD RESOURCES INC to 8610, TRIAD HUNTER LLC
APP 2015-05-11 Proposed Formations:BEREA, Issued Date:5/11/2015, Expired Date:5/10/2017 12:00:00 PM, Drilling unit acres:160, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2016-08-03 I.P. NONE RPT.
Record Last Modified 2017-02-15 I.P. NONE RPT.
Construction Permit Expires 2017-05-10 I.P. NONE RPT.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 PETROEL 0.00 0.00 0
1989 PETROEL 0.00 0.00 0
1990 PETROEL 0.00 0.00 365
1991 PETROEL 0.00 0.00 0
1995 PETROEL 0.00 0.00 365
2013 TRIAD HUNTER LLC 0.00 342.00 365
2014 TRIAD HUNTER LLC 0.00 394.00 365
2015 TRIAD HUNTER LLC 0.00 0.00 0
2016 TRIAD HUNTER LLC 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 PETROEL Brine 0 0
1989 PETROEL Brine 0 0
1990 PETROEL Brine 0 365
1991 PETROEL Brine 0 0
1995 PETROEL Brine 0 365
2013 TRIAD HUNTER LLC Brine 33 365
2014 TRIAD HUNTER LLC Brine 30 365
2015 TRIAD HUNTER LLC Brine 0 0
2016 TRIAD HUNTER LLC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2061665391 2016-11-7 0:00: FR No Violations 1.50
-810184390 2016-3-24 0:00: PW No Violations 2.00
0810184390 2016-03-24 Production Wells No Violations Upon my inspection today I found this well to have had its pump jack removed and the valves are closed in on the 2 inch production line. The well has had production reported for it in 2014, and I will be calling Triad to see if there was a mix up in production reports or if they can prove this well is capable of production.
1243426072 2009-05-21 Production Wells Violations Noted An inspection of the well revealed no pump jack on well, no production tanks. House gas may be used from well, no one at house. Unable to do a full inspection on well due to dogs. No production reported on well since well was drilled.
1337177918 2012-05-15 Production Wells No Violations Well id idle and all production equipment has been removed and is incapable of production in its current state -no house gas hook up, no reported production from time of completion.
1470671117 2016-08-03 Plug / Plug Back No Violations I was on location to witness Cemenco set a Berea plug (1771-1371) and a bottom of surface plug (240-0). There was circulation on all plugs and some oil. They used a total of 35 sacks of Class A cement. We used Appalachian Well Services to log the hole and we were going to shoot the 4 1/2 inch diameter pipe off but no free point could be found. When we logged the hole it was found that the 4 1/2 inch diameter casing was cemented on the back side almost clear to surface. There was no 7 inch diameter surface casing in the hole but we found there was a 12-13 inch hole at the surface that was about 15 feet deep. After we plugged to surface we took a piece of tubing and put it in the previously mentioned hole and filled that to surface with 15 sacks of cement. This well is now plugged and all violations have been resolved.
1767292659 2009-07-22 Production Wells No Violations Follow-up on NOV, In-Compliance, house gas being used.
2061665391 2016-11-07 Final Restoration No Violations This well was plugged and abandoned earlier this year. The inspection today revealed that this well has had all equipment removed, vegetation has been established, the pit has been closed and buried, and erosion has been controlled. This well has passed final restoration in accordance with ORC 1509.072(B).

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1243426072 US-OH-106481 2009-05-27 Failure to legibly identify well
1243426072 US-OH-106482 2009-05-27 Well shall be plugged

For data sources see[7]

References