If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-22767 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.08,"lon":-80.92,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Milton Township | |
Operator Name: CEDAR VALLEY ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: STEVENS UNIT | |
License Status: Producing | |
License Date: 2007-07-11 | |
Spud Date: 2007-10-28 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2007-11-04 | |
Well Total Depth: 5071.00 ft | |
Configuration: Vertical | |
Latitude: 41.080000 | |
Longitude: -80.920000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 1997-07-30 | 4939 ENERGY RESOURCES AMERICA Proposed Formation CLINTON Issued Date 7/30/97 Expired Date 7/30/98 6:00:00 AM |
APP | 2007-07-11 | Proposed Formations:CLINTON, Issued Date:7/11/2007, Expired Date:7/10/2008 6:00:00 AM, Drilling unit acres:42.77, Proposed Well Type:OG, Proposed Well Class:POOL |
Completed | 2007-11-04 | RBDMS Rec |
Reached Total Depth | 2007-11-04 | RBDMS Rec |
Completion Report Received | 2008-01-28 | RBDMS Rec |
Construction Permit Expires | 2008-07-10 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-03-26 | 4859 | 4922 | 27 |
4859 | 4922 | 27 | |
4859 | 4922 | 27 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 105708 Gal | 65000 | ALSO USED 100 MSCF OF N2 IN FRAC |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CEDAR VALLEY ENERGY INC | 11754.00 | 878.00 | 279 |
2009 | CEDAR VALLEY ENERGY INC | 12042.00 | 512.00 | 365 |
2010 | CEDAR VALLEY ENERGY INC | 9977.00 | 428.00 | 365 |
2011 | CEDAR VALLEY ENERGY INC | 7359.00 | 252.00 | 365 |
2012 | CEDAR VALLEY ENERGY INC | 5853.00 | 257.00 | 366 |
2013 | CEDAR VALLEY ENERGY INC | 4918.00 | 275.00 | 365 |
2014 | CEDAR VALLEY ENERGY INC | 4912.00 | 205.00 | 365 |
2015 | CEDAR VALLEY ENERGY INC | 4608.00 | 222.00 | 365 |
2016 | CEDAR VALLEY ENERGY INC | 4620.00 | 159.00 | 365 |
2017 | CEDAR VALLEY ENERGY INC | 4021.00 | 172.00 | 365 |
2018 | CEDAR VALLEY ENERGY INC | 3523.00 | 130.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CEDAR VALLEY ENERGY INC | Brine | 466 | 279 |
2009 | CEDAR VALLEY ENERGY INC | Brine | 175 | 365 |
2010 | CEDAR VALLEY ENERGY INC | Brine | 232 | 365 |
2011 | CEDAR VALLEY ENERGY INC | Brine | 50 | 365 |
2012 | CEDAR VALLEY ENERGY INC | Brine | 0 | 366 |
2013 | CEDAR VALLEY ENERGY INC | Brine | 89 | 365 |
2014 | CEDAR VALLEY ENERGY INC | Brine | 134 | 365 |
2015 | CEDAR VALLEY ENERGY INC | Brine | 50 | 365 |
2016 | CEDAR VALLEY ENERGY INC | Brine | 0 | 365 |
2017 | CEDAR VALLEY ENERGY INC | Brine | 35 | 365 |
2018 | CEDAR VALLEY ENERGY INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1720028470 | 2008-2-6 0:00:0 | PL | No Violations | |
-1755765327 | 2007-11-5 0:00: | PL | No Violations | |
-188269777 | 2017-1-25 0:00: | PW | No Violations | 1.00 |
0188269777 | 2017-01-25 | Production Wells | No Violations | I performed status check on the above location. The well is a plunger lift equipped with 1.5 tubing. There is a domestic house gas hook up at the wellhead. The tank battery is equipped with one 100 barrel tank and one horizontal. ID signs are posted. No noted violations at this time. |
0709935578 | 2007-10-30 | Drill / Deepen / Reopen | No Violations | I performed a rig inspection. The pit liners were in good shape. The location was in good shape. There were no violations at this time. |
1193685004 | 2007-10-29 | Drill / Deepen / Reopen | No Violations | I performed a rig inspection. Drilling depth was 204. GPSd the well. Both sets of drilling pit liners in good shape. I found no violations at this time. |
1193774796 | 2007-10-30 | Drill / Deepen / Reopen | No Violations | I witnessed the running of and the cementing of the 8 5/8 casing. I found no violations at this time. |
1194279509 | 2007-11-02 | Drill / Deepen / Reopen | No Violations | I performed a rig inspection. Drilling depth was 3127. Pit liners still in good shape. I found no violations at this time. |
1194803441 | 2007-11-09 | Preliminary Restoration | No Violations | I witnessed the partial pit solidification and closing of both pits. The drilling equipment is gone. The debris has been removed. There were no violations at this time. |
1720028470 | 2008-02-06 | Preliminary Restoration | No Violations | I performed a preliminary restoration status check. The drilling pits are closed. The debris has been removed. The drilling equipment has been removed. The topsoil has been spread over the location. Needs to have the finishing touch and then seeded. This well has not passed preliminary restoration. |
1755765327 | 2007-11-05 | Preliminary Restoration | No Violations | I performed a preliminary restoration status check. Drilling pit liner on the mud pit side had some pit liner burned and water was over the top of the liner. Called Tim Cosma from Cedar Valley Energy (330-853-9565)and told him the water in mud pits need to be vaccumed down below the burned liner. He would have a water truck up to the location within 2 hours to suck the pit down below the bad liner. |
2031584910 | 2008-06-16 | Preliminary Restoration | No Violations | I performed a preliminary restoration status check. I GPSd both the well and the tank battery. The drilling equipment is gone as well as the debris. The drilling pits are closed. There is vegetation growth on the location. The ID sign is posted at the tank battery. This well has PASSED PRELIMINARY RESTORATION. |
709935578 | 2007-10-30 0:00 | DD | No Violations |
For data sources see[9]