34-085-21084

Well Details

Well ID: 34-085-21084
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Geneva Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: LOSELY SUBJECT TRACT
License Status: Producing
License Date: 2003-11-03
Spud Date: 2004-01-12
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2004-01-18
Well Total Depth: 3108.00 ft
Configuration: Vertical
Latitude: 41.790000
Longitude: -81.000000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-11-03 Proposed Formations:CLINTON, Issued Date:11/3/2003, Expired Date:11/2/2004 6:00:00 AM, Drilling unit acres:43.833, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-01-12 RBDMS Rec
Completed 2004-01-18 RBDMS Rec
Reached Total Depth 2004-01-18 RBDMS Rec
Completion Report Received 2004-02-20 RBDMS Rec
Construction Permit Expires 2004-11-02 RBDMS Rec
Change of Owner 2015-07-16 Operator changed from 8685, M & R INVESTMENTS OHIO LLC BROAD STREET ENERGY COMPANY to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-04-26 2884 2916 33
2884 2916 33
2884 2916 33

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 1476 Bbl 70000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 BROAD STREET ENERGY COMPANY 0.00 0.00 0
2004 BROAD STREET ENERGY COMPANY 1563.00 125.00 318
2005 BROAD STREET ENERGY COMPANY 2737.00 68.00 365
2006 BROAD STREET ENERGY COMPANY 3077.00 63.00 365
2007 BROAD STREET ENERGY COMPANY 1689.00 0.00 365
2008 BROAD STREET ENERGY COMPANY 1097.00 0.00 365
2009 BROAD STREET ENERGY COMPANY 964.00 0.00 365
2010 BROAD STREET ENERGY COMPANY 855.00 0.00 365
2011 BROAD STREET ENERGY COMPANY 776.00 0.00 365
2012 BROAD STREET ENERGY COMPANY 635.00 0.00 366
2013 BROAD STREET ENERGY COMPANY 512.00 112.00 365
2014 BROAD STREET ENERGY COMPANY 486.00 0.00 365
2015 M & R INVESTMENTS OHIO LLC 81.00 0.00 365
2016 M & R INVESTMENTS OHIO LLC 336.00 0.00 365
2017 M & R INVESTMENTS OHIO LLC 328.00 0.00 365
2018 M & R INVESTMENTS OHIO LLC 307.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 BROAD STREET ENERGY COMPANY Brine 0 0
2004 BROAD STREET ENERGY COMPANY Brine 1074 318
2005 BROAD STREET ENERGY COMPANY Brine 874 365
2006 BROAD STREET ENERGY COMPANY Brine 473 365
2007 BROAD STREET ENERGY COMPANY Brine 354 365
2008 BROAD STREET ENERGY COMPANY Brine 332 365
2009 BROAD STREET ENERGY COMPANY Brine 238 365
2010 BROAD STREET ENERGY COMPANY Brine 68 365
2011 BROAD STREET ENERGY COMPANY Brine 254 365
2012 BROAD STREET ENERGY COMPANY Brine 347 366
2013 BROAD STREET ENERGY COMPANY Brine 238 365
2014 BROAD STREET ENERGY COMPANY Brine 188 365
2015 M & R INVESTMENTS OHIO LLC Brine 58 365
2016 M & R INVESTMENTS OHIO LLC Brine 114 365
2017 M & R INVESTMENTS OHIO LLC Brine 70 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1106345568 2014-8-6 0:00:0 UP No Violations
-1384776372 2004-1-13 0:00: DD No Violations
-1652262236 2015-4-1 0:00:0 UP No Violations 0.50
-1874647664 2009-9-11 0:00: PL No Violations
-769050092 2019-9-6 0:00:0 UP No Violations
0617279825 2017-11-15 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and associated battery are located on a larger, rural parcel, utilized for a nursery operation The surrounding areas are comprised of tree and shrub growing operations. The well is comprised of a plunger-lift system which was in production. The fittings and connections were secure with no signs of problems or leakage. The associated tank battery is comprised of one 100-bareel steel stock tank and one 100-barrel steel brine tank. Fittings and connections were secure . The load lines were plugged and secure. The ID signage had been updated as previously requested. The battery is shared with the Spear-Yoe-Horton-Murray , located 1,200 feet northwest of the battery. Access road to the wellhead and battery is shared with the nursery and in good condition. I walked and inspected the areas surrounding the wellhead and battery and found no signs of problems or impacts. I noted that the load-line needed a plug. I notified Bill Fitzmartin about the need for a plug.
1106345568 2014-08-06 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 01/18/2004. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and pump jack system. The wellhead is located within the overall confines of a commercial nursery facility. The well and battery are accessed via shared, unpaved roads within the facility. The battery is comprised of 1 steel 40-barrel production tank, 1 100-barrel, steel brine tank, and horizontal separator. Spacing from well to battery, and spacing of elements within the battery meet regulations. The wellhead is not enclosed. The load-outs are bull-plugged. The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery. No problems requiring attention at the time of this inspection.
1384776372 2004-01-13 Drill / Deepen / Reopen No Violations On site to check status drilling 187 .Had trouble with conductor had to pull and re set. 113/4 to 36
1448070749 2004-01-14 Drill / Deepen / Reopen No Violations on site drilling at 450 No gas
1652262236 2015-04-01 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well is producing and production reports are current. The wellhead pump jack is functioning with no signs of leakage or problems. The tank battery is intact. Load-outs are bull-plugged. Secondary containment is intact. ID placards are present. The lease road which is shared with the nursery facility is well drained and free from wash-outs or other erosional deficits. I did not observe any signs of impact relating to the on-going production activity.
1796913310 2014-10-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well is producing and production reports are current. The wellhead pump jack is functioning with no signs of leakage or problems. The tank battery is intact. Load-outs are bull-plugged. Secondary containment is intact. ID placards are present. The lease road which is shared with the nursery facility consists of hard-packed clayey sand and is well drained.
1874647664 2009-09-11 Preliminary Restoration No Violations Preliminary restoration was completed and passed inspection.
2035089452 2017-07-26 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and associated battery are located on a larger, rural parcel, utilized for a nursery operation. At the time of this inspection, I observed the following The fittings and connections were secure with no signs of problems or leakage. The load lines were closed but a plug is was missing. The ID signage needs updated. The battery is shared with the Spear-Yoe-Horton-Murray , located 1,200 feet northwest of the battery. Access road to the wellhead and battery is shared with the nursery and in good condition. I walked and inspected the areas surrounding the wellhead and battery and found no signs of problems or impacts. I noted that the load-line needed a plug. I notified well tender Matt Sisson about the missing plug and need for updated signage. Matt indicated that these issues will be addressed ASAP.
617279825 2017-11-15 0:00 UP No Violations 0.50

For data sources see[9]

References