X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-075-25583

Well Details

Well ID: 34-075-25583
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Hardy Township
Operator Name: BANDS GROUP LLC
Well Pad ID:
Farm/Lease Name: ERB UNIT
License Status: Producing
License Date: 2011-04-12
Spud Date: 2011-06-18
Spud Drilling Contractor: MARIC DRILLING CO.
Final Drill Date: 2011-06-30
Well Total Depth: 5654.00 ft
Configuration: Vertical
Latitude: 40.560000
Longitude: -81.920000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-04-12 Proposed Formations:KNOX, Issued Date:4/12/2011, Expired Date:4/11/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-06-30
Completion Report Received 2011-08-22
Construction Permit Expires 2012-04-11
Change of Owner 2015-01-01 Operator changed from 30, BANDS CO INC to 9384, BANDS GROUP LLC
Record Last Modified 2018-01-30

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-11-23 5517 5580 37
5517 5580 37
5517 5580 37

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-08-03 ACID 15 2500 Gal 0 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 BANDS COMPANY INC 41542.00 708.00 150
2012 BANDS COMPANY INC 169011.00 2187.00 366
2013 BANDS COMPANY INC 170540.00 2183.00 365
2014 BANDS COMPANY INC 187580.00 2026.00 365
2015 BANDS GROUP LLC 160037.00 1304.00 365
2016 BANDS GROUP LLC 146130.00 1044.00 365
2017 BANDS GROUP LLC 165945.00 708.00 365
2018 BANDS GROUP LLC 73969.00 447.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 BANDS COMPANY INC Brine 0 150
2012 BANDS COMPANY INC Brine 0 366
2013 BANDS COMPANY INC Brine 0 365
2014 BANDS COMPANY INC Brine 0 365
2015 BANDS GROUP LLC Brine 0 365
2016 BANDS GROUP LLC Brine 0 365
2017 BANDS GROUP LLC Brine 0 365
2018 BANDS GROUP LLC Brine 14 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1110354924 2011-6-3 0:00:0 DD No Violations
-1163075294 2011-7-5 0:00:0 DD No Violations
-1209595846 2011-6-30 0:00: UP No Violations 3.00
-1478305045 2011-6-27 0:00: DD No Violations
-1808158289 2011-6-9 0:00:0 DD No Violations
-1838868300 2015-7-30 0:00: PW No Violations
-1848750311 2015-8-3 0:00:0 PW No Violations
-2020059245 2016-7-6 0:00:0 PW No Violations
-2032335316 2011-7-20 0:00: DD No Violations
-592893495 2015-7-28 0:00: PW No Violations
-966302447 2011-6-20 0:00: DD No Violations
0038523563 2011-06-13 Drill / Deepen / Reopen No Violations Cutting location. Silt fence to be set today. Signage to be placed today.
0173742643 2014-06-11 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
0484570607 2011-06-23 Drill / Deepen / Reopen No Violations Drilling ahead on fluid at 2393.
0592893495 2015-07-28 Production Wells No Violations An operator of Cobra pipeline shut the sales line in w/o notifying the Producer. The well was feeding on line at the time and the pressure blew a lineof the motor valve inside the production unit and the gas caught fire and burned up the unit. The Millersburg FD put out the fire with foam. There are 2 bbls of oil inside the dike around the production unit. Nothing got outside the dike. A vacuum truck is on the way to suck out the dike and roustabouts are on standby to clean up the residuals .
0616704041 2019-05-01 Production Wells No Violations On the day of my inspection I found an 8 5/8-inch diameter casing, a 4 1/2-inch diameter casing, and 2 3/8-inch diameter tubing and rods. The well is operated by a pumping unit with an electric motor. The production equipment is made up of one 210 bbl. steel tank, a production separator, a vertical separator, and a rotary meter. The tank is properly identified. The production reporting is up to date.
0966302447 2011-06-20 Drill / Deepen / Reopen No Violations Ran 14 joints of 8-5/8 23# R-3 casing 588 set at 598. Petroset cemented with 220 sx regular Class A with 3% caCl2. 10 bbl of good cement returned to surface. Plug down at 11:45 AM. See casing ticket for more information.
0969048981 2013-01-14 UrbanPreliminary Restoration No Violations There is good grass growth. All fences are in place and the gates locked. This is a producing pump jack well. There were no problems noted at the time of the inspection. Urban preliminary Restoration has passed.
1060294513 2011-05-24 Drill / Deepen / Reopen No Violations Urban location. Met with Brett Smith to make sure we were all on same page with placement of drilling equipment and safety fences etc.
1110354924 2011-06-03 Drill / Deepen / Reopen No Violations Waiting on loggers to cut trees.
1163075294 2011-07-05 Drill / Deepen / Reopen No Violations Reserve pit emptied and closed. Floccing working pit.
1209595846 2011-06-30 UrbanProduction Wells No Violations Maric Drilling set 4.5 casing at 5548 ft . Total depth of well at 5550.
1308221937 2011-06-15 Urban Drill / Deepen / Reopen No Violations All silt fence in place and location fenced.
1309970132 2011-06-28 Drill / Deepen / Reopen No Violations Drilling ahead on fluid at 5116 in the Utica shale.
1310409131 2011-07-11 Drill / Deepen / Reopen No Violations Working pit emptied. No service rig yet.
1311015170 2011-07-18 Drill / Deepen / Reopen No Violations Seting tank Battery. Waiting on power before acidizing.
1312396723 2011-08-03 Drill / Deepen / Reopen No Violations Acidized with 2500 gallons of 15% acid. BDP 1300psi. 2.1 BPM at 1300 psi. ISIP 650 psi
1312540043 2011-08-04 Preliminary Restoration No Violations Well is producing. Working on putting the location back.
1314643782 2011-08-29 Preliminary Restoration No Violations Final grade not yet hydro-seeded.
1318336569 2011-10-11 UrbanPreliminary Restoration No Violations Final grade completed and location has been seeded and mulched. Fences have been erected around pumping unit, production unit, and tank battery. All gates locked and signs in place.
1319539562 2011-10-24 Preliminary Restoration No Violations Grasses growing and should hold upduring winter. Will check back in spring. Well is producing, signs are in place, fences are up and the gates are locked.
1351706282 2011-06-14 Drill / Deepen / Reopen No Violations Pits cut and lined, some water added to hold them. Fence put up around location. Warning signs up. Silt fence in place.
1438253944 2015-07-29 Production Wells No Violations Checked the status of the clean up from the aftermath of the production unit fire. The oil and water have been removed from inside the dike and the residuals have been soaked up with peat sorb. The fire actually was the result of a failed insulated union. The pop-off was set for 500 psig and the well shut down was set for 300 psig. The well shut down worked but the insulted union on the up stream side of the motor valve failed causing the fire.
1476451626 2011-08-02 Drill / Deepen / Reopen No Violations Bond log showed cement top at 4875. Good bond through and above perforated interval. First perforation run did not fire.
1478305045 2011-06-27 Drill / Deepen / Reopen No Violations Drilling ahead on fluid at 4638 in Utica shale.
1493034481 2017-04-21 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
1538567150 2018-10-03 Production Wells No Violations On the day of my inspection I found an 8 5/8 inch diameter casing, a 4 1/2 inch diameter casing, and 2 3/8 inch diameter tubing and rods. The well is operated by a pumping unit with an electric motor. The production equipment is made up of one 210 bbl. steel tank, a production separator, a vertical separator, and a rotary meter. The tank is properly identified. The production reporting is up to date.
1566991752 2019-8-29 0:00: PW No Violations 0.50
1577104979 2019-12-23 0:00 PW No Violations 0.30
1579893578 2020-1-24 0:00: PW No Violations 0.50
1719358061 2011-09-26 Preliminary Restoration No Violations Well is to final grade (and has been) but unable to seed and mulch due to unusally heavy rain over last several weeks.
173742643 2014-6-11 0:00: PW No Violations
1808158289 2011-06-09 Drill / Deepen / Reopen No Violations Met tool pusher on location. Waiting on loggers to remove trees so he can start cutting location.
1838868300 2015-07-30 Production Wells No Violations They are setting and plumbing in a new production unit to replace the one that burned. The old unit is out of the dike and the new oneis in. They are filling the reservoir with 50/50 water/antifreeze.
1848750311 2015-08-03 Production Wells No Violations The production unit has been replaced and plumbed in and the well is back on line after the production unit fire.
2020059245 2016-07-06 Production Wells No Violations This is a producing pump jack well. There were no problems noted at the time of the inspection.
2032335316 2011-07-20 Drill / Deepen / Reopen No Violations Tank battery set. Waiting on electic drop.
38523563 2011-6-13 0:00: DD No Violations
466744042 2020-8-11 0:00: PW No Violations 0.30
484570607 2011-6-23 0:00: DD No Violations
616704041 2019-5-1 0:00:0 PW No Violations 0.50
969048981 2013-1-14 0:00: UL No Violations

For data sources see[9]

References