34-059-24501

Well Details

Well ID: 34-059-24501
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Oxford Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001462
Farm/Lease Name: RABER W LND GR
License Status: Producing
License Date: 2017-04-19
Spud Date: 2017-05-03
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2017-10-06
Well Total Depth: 19886.00 ft
Configuration: Horizontal
Latitude: 40.080000
Longitude: -81.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-04-19 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:4/19/2017, Expired Date:4/19/2019 12:00:00 PM, Drilling unit acres:685.362, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2017-10-06
Record Last Modified 2019-01-02
Construction Permit Expires 2019-04-19

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 12/13/2017 02/22/2018 7583 22,139,000.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 89.1717 184,639,000.0
FE-2A Halliburton Additive Listed Below Listed Below 0 0 0
SP BREAKER Halliburton Breaker Listed Below Listed Below 0 0 0
Inorganic salt Proprietary 30 0.0163781 33913
Acetic acid 64-19-7 100 0.00237882 4927
Hydrochloric acid 7647-01-0 7.5 0.08679 179706
Sodium persulfate 7775-27-1 100 0.00000048 1
Propargyl alcohol 107-19-7 10 0.00008732 181
Ethanol 64-17-5 1 0.000212032 440
Acetic anhydride 108-24-7 100 0.00142799 2957
Sodium sulfate 7757-82-6 0.1 0.00000000 1
Acrylamide acrylate copolymer Proprietary 30 0.0163781 33913
Modified thiourea polymer Proprietary 30 0.000261959 543
Glutaraldehyde 111-30-8 30 0.00636097 13172
Acrylic acid 79-10-7 0.01 0.00000236 5
Ethylene glycol 107-21-1 60 0.0141598 29320
Guar gum 9000-30-0 100 0.00002463 51
Crystalline silica, quartz 14808-60-7 100 9.56181 19,798,700.0
Phosphoric acid 7664-38-2 0.1 0.00002120 44
Sodium polyacrylate 9003-04-7 1 0.000235997 489
Fatty acids, tall oil Proprietary 30 0.000261959 543
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.00106016 2196
Methanol 67-56-1 60 0.000553602 1147
Hydrotreated light petroleum distillate 64742-47-8 30 0.0163781 33913
Citric acid 77-92-9 60 0.00365486 7568
Olefins Proprietary 5 0.000104784 220
Ethoxylated alcohols Proprietary 30 0.000261959 543
Telmer Proprietary 10 0.00235997 4887
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
SAND-COMMON WHITE-100 MESH Halliburton Proppant Listed Below Listed Below 0 0 0
FE-1A ACIDIZING COMPOSITION Halliburton Additive Listed Below Listed Below 0 0 0
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0
SAND-PREMIUM WHITE-30/50 Halliburton Proppant Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 1.22536 2,537,230.0
SCALECHEK LP-70 Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
FE-1 Halliburton Additive Listed Below Listed Below 0 0 0
WG-36 GELLING AGENT Halliburton Gelling Agent Listed Below Listed Below 0 0 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0
0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC 835131 158074 273
2019 ASCENT RESOURCES UTICA LLC 216099 25626 90

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC Brine 29139 273
2019 ASCENT RESOURCES UTICA LLC Brine 4184 90

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-227204443 2020-5-26 0:00: PW No Violations 1.00
-756087341 2017-10-10 0:00 DD No Violations 1.00
0032167199 2019-02-07 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Gauges were present on all casing strings. The 13.375-inch diameter surface casing had 50 pounds per square inch and the 9.625-inch diameter intermediate had 0 pounds per square inch. The production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor. The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry. Ascent well tender was on location along with two Wise tanker trucks that were loading produce fluids from the tank battery.
0071884220 2017-05-04 Casing String Witnessed No Violations On the day inspection I witnessed that Precision Rathole had drilled a 36 inch diameter hole to the depth of 100 feet, hitting water at 40 feet and ran 100 feet of 30 inch 118.65 pounds per foot conductor pipe. O-Tex Pumping LLC was onsite and performed a 200 pounds per square inch pressure test, gained circulation with 2 barrels of fresh water and cemented pipe with 330 sacks Class H cement with 1.5% Calcium Chloride, .2% X--flake weighing 15.6 pounds per gallon and a yield of 1.2 cubic foot per sack. Cement was weight was verified with pressurized mud scales and displaced to 90 feet with 74.8 barrels of fresh water with good cement returns of 24 barrels to surface. Mix water was tested revealing chlorides of 54 parts per million, pH 7 and 59 degrees.
0482023389 2018-05-17 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. The wells on the pad are in the process of flowing back. The production equipment consisted of nine barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor.
0756087341 2017-10-10 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson UTI Drilling Rig #584 had completed move from location and Myers Well Service was onsite cleaning rig mats.
0786712843 2018-09-12 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. Gauges were present on all casing strings. The 9.625-inch diameter intermediate casing had 300 pounds per square inch and the 13.375-inch surface casing had 50 pounds per square inch. The production equipment consisted of nine 400-barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and two combustors. The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry.
0796659432 2018-02-05 Completion Testing No Violations On the day of my inspection I witnessed Halliburton Services had screened of stage 51 of 80 with 75000 pounds of 100 mesh and 36000 pounds of 30/50 mesh sand put away. The 5.5 inch diameter casing was perforated with 40 shots from 12438 feet to 12306 feet. Three unsuccessful attempts have been made trying to get back into the formation with IPS coil tubing unit in-route. I met with Ascent Consultants Delbert Brown, Larry Jennings and Andy Ramoni and discussed their plans and completed a walk around.
0832317954 2017-09-19 Drill / Deepen / Reopen No Violations On the day of my inspection following up from call on 9/12/17 where it was reported that the derrick hand left the valve on the barite hopper open when he went to the rig floor resulting in a 50 barrel spill of oil based mud (OBM) on containment and 5 gallons leaving containment, I witnessed that the area had been remediated with 49 barrels and 37 gallons recovered and mixed off. When the rig has completed drilling this well all mats will be removed and any residual OBM will be removed and properly disposed. No OBM was found off the well pad with all sump drains in the closed position. Patterson UTI Drilling Rig #584 was drilling ahead on air with a 12.25 inch diameter bit at 4233 feet with a planned total depth in the intermediate section of 6700 feet. KLX Energy Services was onsite making up the shoe track for the intermediate section. Shoe track consisted of 2 joints of 9.625 inch diameter 40 pound per foot L-80 casing with a Halliburton float shoe, 1 Centek centralizer and a Halliburton float collar.
1134500937 2017-10-02 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson UTI Drilling Rig #584 had reached a total depth in the 8.5 inch diameter lateral at 19886 feet and was tripping out of the wellbore at 16517 feet. Patterson UTI Drilling Rig #584 was performing a clean-up cycle to remove built up from the wellbore to decrease drag tripping out. I completed walk around with Ascent Consultant Alan Rice revealing 5.5 inch diameter 23 pound per foot production casing along with float equipment and centralizers were staged for the upcoming casing and cementing job.
1494890943 2017-05-15 Casing String Witnessed No Violations On the day of my inspection I witnessed that Falcon Drilling Rig #26 had drilled a 17.5 inch diameter hole to the depth of 1225 feet and Wyoming casing crew ran 1216 feet of 13.375 inch 61 pounds per foot J-55 casing 4.8 feet above KB. O-Tex Pumping LLC was on site and gained circulation with 5 barrels of fresh water, 35 barrels of gel, 10 barrels of fresh water and cemented casing with 1340 sacks of Class H cement with 1.5% Calcium Chloride, .2% X--<39 parts per million, pH 7 and 55 degrees.
1989158782 2018-07-06 Preliminary Restoration No Violations The purpose of my inspection was a status check on a preliminary restoration. During my inspection the well was equipped with a production tree style wellhead with valves in the open position. The production equipment consisted of nine 400 barrel tanks, two vapor recovery towers, six sand traps, six gas production units, three horizontal heater treaters, one compressor, one vertical vent scrubber, and one combustor. The area effected by the pad construction has been restored with vegetation coverage. The lease road and well pad consisted of a gravel surface with no erosion issues. The location has met preliminary restoration requirements written within 1509.072 (A). The identification was posted at the well, tank battery, and entry. Laminated copies of the Drilling permits were posted at entry.
32167199 2019-2-7 0:00:0 PW No Violations 0.20
482023389 2018-5-17 0:00: PW No Violations 0.20
71884220 2017-5-4 0:00:0 CS No Violations 3.00
786712843 2018-9-12 0:00: PW No Violations 0.20
796659432 2018-2-5 0:00:0 CT No Violations 2.00
832317954 2017-9-19 0:00: DD No Violations 2.00

For data sources see[9]