X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24303

Well Details

Well ID: 34-059-24303
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Londonderry Township
Operator Name: GULFPORT APPALACHIA LLC
Well Pad ID: US-OH-000533
Farm/Lease Name: RIPLEY
License Status: Producing
License Date: 2013-07-19
Spud Date: 2014-05-14
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2014-07-18
Well Total Depth: 13975.00 ft
Configuration: Horizontal
Latitude: 40.140000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-07-19 Proposed Formations:POINT PLEASANT, Issued Date:7/19/2013, Expired Date:7/19/2015 12:00:00 PM, Drilling unit acres:625.078, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2014-06-27 CHANGE IN TARGET INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE DECREASED TO 623.320 ACRES.
Reached Total Depth 2014-07-18
Correction to Well 2015-01-09 UPDATE TO TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2015-06-15
Construction Permit Expires 2015-07-19
Record Last Modified 2017-10-24

For data sources see[2]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/07/2014 09/21/2014 7574 12,124,200.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 OptiKleen-WF(TM) Halliburton Concentrate Sodium perborate tetrahydrate 10486-00-7 100 0.0119976 0
FE-2A Halliburton Additive Citric acid 77-92-9 60 0.00381781 0
FRA-407 Operator Friction Reducer Ammonium acetate 631-61-8 5 0.0012 0
Petroleum distillates, hydrotreated light 64742-47-8 40 0.00962 0
Water 7732-18-5 55 0.01323 0
HCl 10% Halliburton Solvent Hydrochloric Acid 7647-01-0 10 0.00191065 0
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.000863072 0
HCl 7.5% Halliburton Solvent Hydrochloric Acid 7647-01-0 7.5 0.0354148 0
HCl 15% Halliburton Solvent Hydrochloric Acid 7647-01-0 15 0.014674 0
Other Purpose Ammonium chloride 12125-02-9 0 0.00522303 0
Olefins Confidential 0 0.00003498 0
Polyacrylate Confidential 0 0.00720888 0
Sorbitan, mono-9-octadecenoate, (Z) 1338-43-8 0 0.000804485 0
Alcohols, C14-C15, ethoxylated 68951-67-7 0 0.000205493 0
Formaldehyde 50-00-0 0 0.00009881 0
Sorbitan monooleate polyoxyethylene derivative 9005-65-6 0 0.000804485 0
Reaction product of acetophenone,

formaldehyde, thiourea and oleic acid in dimethyl formamide

68527-49-1 0 0.000205493 0
Organic phosphonate Confidential 0 0.00591646 0
Sodium chloride 7647-14-5 0 0.00402155 0
Alcohols, C12-16, ethoxylated 68551-12-2 0 0.00120148 0
Alcohols ethoxylated Confidential 0 0.00402155 0
Olefins Confidential 0 0.00000700 0
Inorganic salt Confidential 0 0.00240296 0
Polyacrylamide copolymer Confidential 0 0.0241276 0
Water 7732-18-5 0 0.0810335 0
Fatty acid ester Confidential 0 0.000240471 0
Amide Confidential 0 0.00522303 0
Fatty acids, tall oil Confidential 0 0.000205493 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Propargyl alcohol 107-19-7 10 0.00006908 0
Methanol 67-56-1 60 0.000410987 0
Scalechek(R) LP-65 Scale Inhibitor Halliburton Scale Inhibitor Ammonium chloride 12125-02-9 10 0.000986368 0
FRA-405 Operator Friction Reducer Water 7732-18-5 36 0.02879 0
Ammonium chloride 12125-02-9 7 0.0056 0
Alcohol, C12-16, Ethoxilated 68551-12-2 7 0.0056 0
Petroleum Distillate 64742-47-8 40 0.03199 0
Sodium Chloride 7647-14-5 10 0.008 0
SAND - PREMIUM WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 10.8437 0
Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 88.4197 0
FE-1A ACIDIZING COMPOSITION Halliburton Additive Acetic acid 64-19-7 60 0.00331238 0
Acetic anhydride 108-24-7 100 0.00551947 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-09-07 H2O 0 377230 Gal 155600 Halliburton STAGE 1/31

45 SHOTS STAGES 2-30

2014-09-20 H2O 8 370777 Gal 156900 Halliburton STAGE 31/31

45 SHOTS

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 GULFPORT ENERGY CORPORATION 63583 15047 30
2015 GULFPORT ENERGY CORPORATION 553946 111315 342
2016 GULFPORT ENERGY CORPORATION 294464 37085 347
2017 GULFPORT ENERGY CORPORATION 192199 21181 353
2018 GULFPORT ENERGY CORPORATION 131062 14815 297
2019 GULFPORT ENERGY CORPORATION 31919 3407 88

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 GULFPORT ENERGY CORPORATION Brine 4642 30
2015 GULFPORT ENERGY CORPORATION Brine 13998 342
2016 GULFPORT ENERGY CORPORATION Brine 3371 347
2017 GULFPORT ENERGY CORPORATION Brine 1951 353
2018 GULFPORT ENERGY CORPORATION Brine 2179 297
2019 GULFPORT ENERGY CORPORATION Brine 294 88

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1302053334 2016-9-6 0:00:0 PW No Violations 0.20
-1820396205 2015-1-12 0:00: PL No Violations 0.50
-2099071539 2014-7-7 0:00:0 CS No Violations
-234175438 2018-5-2 0:00:0 PW No Violations 0.20
-25135081 2020-10-22 0:00 PW No Violations 1.00
-367082164 2018-4-19 0:00: PW No Violations 0.20
-961929668 2017-2-7 0:00:0 PW No Violations 0.30
0234175438 2018-05-02 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. The production equipment consisted of eight 400 barrel tanks, one 50 barrel tank, a vapor recovery tower, two compressors, a vertical heater treater, a gas combustor, back-up flare stack, a horizontal line heater, a vertical separator, and a sand trap.
0367082164 2018-04-19 Production Wells No Violations The purpose of my inspection was to follow up on a fire that occurred on the Northeast side of the pad. The containment under the vertical heater treater ignited and caught fire which eventually spread to the vegetation beside the pad. During my inspection the wells were shut in and contractors were installing new containment under the vertical heater treater. The production equipment consisted of eight 400 barrel tanks, one 50 barrel tank, a vapor recovery tower, two compressors, a vertical heater treater, a gas combustor, back-up flare stack, a horizontal line heater, a vertical separator, and a sand trap.
0521404994 2019-02-14 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present with valves reading 0 pounds per square inch on the 13.375-inch diameter surface casing, and 200 pounds per square inch on the 9.625-inch diameter intermediate casing which was plumbed into the production flow line. The production equipment on pad consisted of four vertical separators, four sand traps, four horizontal indirect line heaters, one vertical heater treater, eight 400-barrel tanks, one 50-barrel tank, one vapor recovery tower, one gas combustor, and one flare stack. Identification was located on the wellhead.
0859296207 2016-04-07 Production Wells No Violations On the day of my inspection I witnessed that the location was gated and locked. The production equipment included 8-400bbl tanks and 1-50bbl tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 3-26H, and Ripley 4-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 550psi on the tubing and 300psi on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
0928372958 2014-07-07 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Patterson Drilling Rig#257 had skidded from the 3-26H and drilled a 17.5 inch diameter hole to the depth of 357 feet. Franks Casing Crew was on site and began to run casing and on the second joint their tongs broke and became stuck on the casing. I left and will return later after repairs are made.
0958142348 2014-07-10 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson UTI Drilling Rig #257 drilled a 12.25 inch diameter hole to the depth of 2070 feet and Wyoming Casing crew ran 2050 feet of 9.625 inch 36#/ft. J-55 Intermediate Casing. Stingray Cementing pumped 50bbls of gel, 10bbls of fresh water and cemented casing with 799 sacks of class A cement. Good cement returns of 38bbls plug was landed @980and pressured up to 1480psi for 5 minutes and the floats held. Cement stayed to surface.
0961929668 2017-02-07 Production Wells No Violations On the day of my inspection I witnessed the production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 3-26H, and Ripley 4-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 200 pounds per square inch on the tubing and 450 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
1302053334 2016-09-06 Production Wells No Violations On the day of my inspection I witnessed that the location was gated and locked. The production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 3-26H, and Ripley 4-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a production tree with valves in the open position with 200 pounds per square inch the tubing and 400 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
1400256169 2014-05-16 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Express Energy Services drilled a 32 inch diameter hole to the depth of 100 feet and ran 105 feet of 26 inch 102.63#/ft conductor pipe. Stingray Cementing was on site and gained circulation with 25bbls of fresh water. Stingray pumped 15bbls of gel, 10bbls of fresh water and cemented pipe with 236 sacks of class A cement. Good returns of 9bbls and cement stayed surface.
1404797915 2014-07-08 Casing String Witnessed No Violations

-55 casing. Patterson 257 had to wash down the last joint of casing. Stingray Cementing was on site and circulated the hole with 110bbls of fresh water. Stingray Cementing pumped 25bbls of gel, 10bbls of fresh water and cemented casing with 474 sacks of class A cement 15.6ppg, 1.2cuft/sk. cement. Displaced cement with 49bbls of fresh water had good cement returns of 9bbls, plug was landed and pressured to 509psi for 5 minutes and the floats held.

1406247434 2014-07-24 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Patterson Drilling Rig #257 had drilled a 17.5 inch diameter hole to the depth 357 feet and 357 feet of 13.375 inch 54.5#/ft. casing. Stingray Cementing LLC cemented said casing with Inspector Mike Hartshorn witnessing 10bbls of cement to surface. Casing head failed pressure test and had to be cut off and replaced with a new head. Casing head passed pressure test along with BOP test.
1729304961 2014-07-09 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that BOP testing was completed and Patterson Drilling Rig #257 was mist drilling with a 12.25 inch diameter bit at a depth of 1009 feet with an estimated td of 2050 feet with intermediate casing to follow. Walk around with Company Man Manuel Olmos revealed no violations.
1820396205 2015-01-12 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A.
1854721157 2017-07-25 Production Wells No Violations On the day of my inspection I witnessed the production equipment included 8-400 barrel tanks and 1-50 barrel tank within containment, a vapor recovery tower, a vapor blow case, a disconnected horizontal 3-phase separator, 2-compressor units, a vertical heater treater, a gas combustor and back-up flare stack all shared with the Ripley 1-26H, Ripley 3-26H, and Ripley 4-26H. Also present a horizontal line heater, a vertical separator and a sand trap. The well was equipped with a plunger lift system with valves in the open position with 250 pounds per square inch on the tubing and 400 pounds per square inch on the casing. Annular pressure monitoring was present along with proper identification and production records being current.
2099071539 2014-07-07 Casing String Witnessed No Violations
521404994 2019-2-14 0:00: PW No Violations 0.30
859296207 2016-4-7 0:00:0 PW No Violations 0.20
928372958 2014-7-7 0:00:0 DD No Violations 2.00
958142348 2014-7-10 0:00: DD No Violations 5.50

For data sources see[9]

References