X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-059-24293

Well Details

Well ID: 34-059-24293
Loading map...
Country: United States
State: Ohio
County: Guernsey
Municipality: Richland Township
Operator Name: UTICA RESOURCE OPERATING LLC
Well Pad ID: US-OH-000560
Farm/Lease Name: DETWEILER
License Status: Plugged Back
License Date: 2013-06-12
Spud Date: 2013-07-08
Spud Drilling Contractor:
Final Drill Date: 2013-07-20
Well Total Depth:
Configuration: Vertical
Latitude: 39.980000
Longitude: -81.380000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-06-12 Proposed Formations:POINT PLEASANT, Issued Date:6/12/2013, Expired Date:6/12/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Original Spud 2013-07-07
Reached Total Depth 2013-07-20
Construction Permit Expires 2015-06-12
Completion Report Received 2017-11-07
Change of Owner 2018-05-04 Operator changed from 8595, PDC ENERGY INC to 10114, UTICA RESOURCE OPERATING LLC
Record Last Modified 2018-05-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-09-04 8096 12446 0
8096 12446 0
8096 12446 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/15/2013 10/15/2013 7000 5,921,960.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Alpha 1427 Baker Hughes Biocide Glutaraldehyde 111-30-8 30 0.00647841 3706.68
Quaternary ammonium chloride 7173-51-5 10 0.00215947 1235.56
Alkyl dimethyl benzyl ammonium chloride (c12-16) 68424-85-1 7 0.00151163 864.892
Water 7732-18-5 60 0.0129568 7413.36
Ethanol 64-17-5 5 0.00107974 617.78
GW-3LDF Baker Hughes Gellant Petroleum Distillate Blend Proprietary 70 0.159538 91280.9
Guar Gum 9000-30-0 40 0.0911644 52160.5
FRW-18 Baker Hughes Friction Reducer Hydrotreated light distillate 64742-47-8 30 0.030957 17712.3
GBW-5 Baker Hughes Water Ammonium Persulfate 7727-54-0 98 0.00111161 636.02
CL-14 Baker Hughes Corrosion Inhibitor Propargyl alcohol NA 4 0.00003332 19.065
Methanol 67-56-1 67 0.000558143 319.346
Enzyme G-NE Baker Hughes Breaker Enzyme G-NE NA 100 0.0269226 15404
Scaletrol 720 Baker Hughes Scale Inhibitor Diethylene glycol 111-46-6 4 0.000886559 507.252
Ethylene glycol NA 44 0.00975215 5579.78
Gasflo G Baker Hughes Surfactant Water 7732-18-5 70 0.060564 34652.2
Methanol 67-56-1 30 0.025956 14851
Surfactants NA 60 0.051912 29701.9
Water Operator Carrier/Base Fluid Water 7732-18-5 100 83.3689 47,700,300.0
Sand (Proppant) Baker Hughes Proppant Silica Substrate NA 100 15.4517 8,840,820.0
BF-9L Baker Hughes Buffer Potassium hydroxide 1310-58-3 30 0.017037 9747.9
Potassium carbonate 584-08-7 60 0.0340741 19495.8
Ferrotrol 300L Baker Hughes Iron Control Citric acid 77-92-9 70 0.00336579 1925.77
XLW-32 Baker Hughes Crosslinker Methanol 67-56-1 60 0.0206806 11832.6
Boric acid 10043-35-3 30 0.0103403 5916.3
Methyl borate 121-43-7 30 0.0103403 5916.3
Hydrochloric Acid (15%) Baker Hughes Acidizing Hydrochloric Acid 7647-01-0 15 0.0889546 50896.2

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 PDC ENERGY INC Brine 1241 26
2014 PDC ENERGY INC Brine 13237 365
2015 PDC ENERGY INC Brine 3837 364
2016 PDC ENERGY INC Brine 2763 366
2017 PDC ENERGY INC Brine 2239 364
2018 UTICA RESOURCE OPERATING LLC Brine 1228 273
2019 UTICA RESOURCE OPERATING LLC Brine 380 90

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-109862226 2014-1-28 0:00: PL No Violations 0.50
-1242256205 2016-12-20 0:00 PW No Violations 0.50
-1275362273 2013-7-17 0:00: DD No Violations
-1561297818 2013-12-13 0:00 PW No Violations
-264675060 2017-10-24 0:00 PW No Violations 0.50
-542081982 2015-7-16 0:00: PW No Violations 0.50
0109862226 2014-01-28 Preliminary Restoration No Violations The site passed preliminary restoration according to 1509.072A.
0264675060 2017-10-24 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a GP Unit, a vapor recovery system, a gas combustor and a total of 8-500 barrel tanks all within containment and shared with the 3H and 42-3H. The well was equipped with a plunger lift system with valves in the open position. Gauge present read 420 pounds per square inch on the tubing and 590 pounds per square inch on the casing. Identification was present with production records current.
0516910737 2014-09-18 Preliminary Restoration No Violations On the day of my inspection I witnessed that the site passed preliminary restoration according to ORC 1509.072A
0542081982 2015-07-16 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a GP Unit, a vapor recovery system, a gas combustor and a total of 8-500bbl tanks all within containment and shared with the 3H and 42-3H. The well was equipped with a plunger lift system with valves in the open position. Gauge present read 510psi on the tubing. Identification was present with production records current.
0867500305 2016-03-15 Production Wells No Violations On the day inspection following up on complaint ID 5259, I witnessed that the production equipment included a GP Unit, a vapor recovery system, a gas combustor and a total of 8-500bbl tanks all within containment and shared with the 3H and 42-3H. The well was equipped with a plunger lift system with valves in the open position. Identification was present with production records current. Completed walk around with PDC Well Technician Carl Caplinger revealing equipment was functioning properly.
1181067054 2018-05-03 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. The gauge on the production casing read 616 and the gauge on the production tubing read 315. Annular pressure monitoring was present. The production equipment consisted of eight 500 barrel tanks with three vapor recovery towers, three gas production units, one gas compression skid, horizontal vent scrubber, and one combustor. Identification was present and production records were current.
1242256205 2016-12-20 Production Wells No Violations On the day of my inspection I witnessed that the production equipment included a GP Unit, a vapor recovery system, a gas combustor and a total of 8-500 barrel tanks all within containment and shared with the 3H and 42-3H. The well was equipped with a plunger lift system with valves in the open position. Gauge present read 595 pounds per square inch on the tubing and 630 pounds per square inch on the casing. Identification was present with production records current.
1275362273 2013-07-17 Drill / Deepen / Reopen No Violations On the day of my inspection, I witnessed the rig currently drilling for the 9.625 casing, there has been no spills to record, the location has containment control and erosion control.
1456326003 2016-02-24 Production Wells No Violations Inspection response to complaint # 5259. Upon inspection the following was observed at the well head- the well is equipped with a tubing head and casing head with the production flow line valve in the open position. Addressing the production facility and equipment- a total of (8) production tanks are present along with 3 vertical sand trap separators all located inside a polymer lined metal containment dike area. Also on location is 3 gas processing units processing the fluid from the 3 existing wells on location. Supporting the production facility is a low pressure vapor recovery system that is supported by a vapor recover burner system that is on the day of my inspection operating, with the vapor recovery ignition stack found to be located at a coordinates of 39.98900 x 81.38609. Addressing the complaint- On the day of my inspection the wind is noted to be coming from the East and the residence of the individual at 61100 Buzz Kirk Lane does lie a measured distance of 2600 approximately due West and downwind of the well pad. The coordinates for the home is 39.98609 x 81.39547. On this day I did contact a Blake Roush with PDC Energy at 970-260-7028 and inform Him that the landowner identified as Lee Ann Rudd has filed a complaint indicating she is getting a caustic smell during the evening hours inside Her home with the strongest odor between 1:30am and 2:00am. Mr. Roush Indicated the company would follow up on the issue. No compliance issues were present the well pad on the day of my inspection and no gas reading were detected with my meter in the area of the residence or well pad.
1457029720 2013-06-25 Casing String Witnessed No Violations On this day of my inspection with Mike Hartshorn witnessed PDC Energy ran 100 of 30 conductor pipe. Express Energy Services cemented conductor back to surface with 64.41 bbls of class A cement with 2% calc. Displaced cement with 74.8 bbls of fresh water. Good returns of 10 bbls.
1500951216 2019-04-30 Production Wells No Violations The purpose of my inspection was a status check. During my inspection the well was equipped with a plunger lift system with production valves in the open position. Annular pressure monitoring was present. The production equipment consisted of eight 500-barrel tanks with three vapor recovery towers, three gas production units, one gas compression skid, horizontal vent scrubber, and one combustor. Identification was present and production records were current. An ECM tanker truck was loading produced fluids from the tank battery and a Utica Resources well tender was present.
1561297818 2013-12-13 Production Wells No Violations On the day of my inspection, I found the well to be in production, Ergon was there loading oil from (1) of (8) four hundred barrel production tanks that is setting inside a steel sealed containment, there is (3) five hundred barrel fresh water tanks setting inside temporary containment on location, I placed a phone call to PDC Energy to inform them of proper I.D. needs to be posted at the entry and at the well.
516910737 2014-9-18 0:00: PL No Violations 1.00
867500305 2016-3-15 0:00: PW No Violations 1.00
937789985 2020-7-22 0:00: PW No Violations 1.00

For data sources see[7]

References