34-055-21905

Well Details

Well ID: 34-055-21905
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2006-11-15
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 41.5325898531
Longitude: -81.3245270159

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1504185715 2014-01-13 My inspection today found no changes since my last. No violations found.
-1606862349 2013-10-22 I was on location with Tom Hill. The production tank has been over flowed and oil is covering a good area of the inside of the tank battery. Peat sorb has been spread to absorb the oil. I notified Mike Cutter to have the oil contaminated stone and dirt to be removed and replaced with new stone and soil. I was later notified that Scott Miller Contstruction was on location to clean up the spill. No other changes were noticed during my inspection.
-239014146 2006-11-15 Rig moving on site, pits have been built. Operator has bermed east and west side of site and constructed a sump in the south east corner of the site. Silt fence and straw bails have been placed to prevent off site sedimentation. Will spud tonight.
1380718168 2013-10-02 I am on location due to a water well complaint #4484 at 8921 Sherman Rd. The well is equipped with a plunger lift unit. The annulus valve is plumbed up and open. The well and tank battery are in good repair and are surrounded by a locked wooden fence. The tank consists of a 100 BBL production tank, a 50 BBL poly brine tank, and a mechanical separator. The production tank is vented through a 55 gallon charcoal filter and into a spark arrestor. The proper identification is located on the tank battery. The lease road is in stable condition.
1384439591 2013-11-14 My inspection found the outside of the tanks have been steam cleaned. The contaminated stone has been removed from inside the tank battery. No violations found. Nothing else has changed since my last inspection.
1585764292 2007-03-12 Well head is installed. Minor leak around one set of threads and collar. Tank battery is installed. One 50 BBL and one 110 BBL tank on site. Mechanical separator. Drainage is contained on site.
1698891063 2008-01-22 Site has been graded. Land owner is using site as a parking area. Well head and tank battery is fenced. Site is snow covered.
31095876 2007-07-18 Site needs ID sign, final grading needs completed. Litter from the silt fence and pit liner needs cleaned up around the site. Area behind the well head needs graded and seeded. Lease road needs a topcoat of gravel.
930516015 2013-06-25 My inspection found the well to be equipped with a plunger lift unit. The well and the tank battery are in good condition and surrounded by a locked chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The production tanks vent is plumbed through a 55 gallon charcoal filter and then plumbed up into a spark arrestor. The load lines have bull plugs and are locked. The proper identification is located on the tank battery. The lease road is in stable condition.