34-035-22138

Well Details

Well ID: 34-035-22138
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: RATNER SCHOOL
License Status: Producing
License Date: 2009-11-10
Spud Date: 2009-11-16
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2009-11-22
Well Total Depth: 3722.00 ft
Configuration: Vertical
Latitude: 41.480000
Longitude: -81.480000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-11-10 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:11/10/2009, Expired Date:11/10/2010 6:00:00 AM, Drilling unit acres:24.09, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-11-22
Completion Report Received 2010-01-04
Construction Permit Expires 2010-11-10
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-01-21 3559 3583 18
3559 3583 18
3559 3583 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 57308 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 BASS ENERGY CO INC 4237.00 917.00 281
2011 BASS ENERGY CO INC 2520.00 850.00 0
2012 BASS ENERGY CO INC 2181.00 492.00 366
2013 BASS ENERGY CO INC 1436.00 445.00 365
2014 BASS ENERGY CO INC 2267.00 475.00 365
2015 BASS ENERGY CO INC 1373.00 413.00 365
2016 BASS ENERGY CO INC 1016.00 309.00 365
2017 BASS ENERGY CO INC 930.00 322.00 365
2018 BASS ENERGY CO INC 832.00 298.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 BASS ENERGY CO INC Brine 395 281
2011 BASS ENERGY CO INC Brine 140
2012 BASS ENERGY CO INC Brine 45 366
2013 BASS ENERGY CO INC Brine 25 365
2014 BASS ENERGY CO INC Brine 73 365
2015 BASS ENERGY CO INC Brine 40 365
2016 BASS ENERGY CO INC Brine 75 365
2017 BASS ENERGY CO INC Brine 50 365
2018 BASS ENERGY CO INC Brine 25 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1269041678 2013-10-22 0:00 UL No Violations
-1417512898 2010-2-18 0:00: DD No Violations
-1517001977 2015-3-9 0:00:0 UP No Violations 0.50
-1780265085 2017-10-10 0:00 UP No Violations 0.50
-1858298258 2019-10-31 0:00 UP No Violations
-1941885355 2009-11-20 0:00 DD No Violations
-480935182 2009-11-24 0:00 DD No Violations
0480935182 2009-11-24 Drill / Deepen / Reopen No Violations on site for permit condition cementing 4 1/2casing
0871272847 2009-11-17 Drill / Deepen / Reopen No Violations drilled surface hole to 395 will set 361 of 85/8 casing with 200 sacks of class A. Good returns to surface Approximately 8 bbls of cement returns to surface.

Berea at 200-260 (drilling samples)

1061446790 2012-01-05 UrbanPreliminary Restoration No Violations On 01/05/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
1116707684 2010-01-13 Drill / Deepen / Reopen No Violations company still working on well site. Company met with school to change location of tank battery to south of well into hill side. New location LAT/LONG 41.47991 081.48639 also advise Ralph Gregory

to send Pepper Pike the location.

1262614080 2009-11-16 Drill / Deepen / Reopen No Violations On site checking permit condition, digging pits on southwest side, location fenced in with construction fencing; Surface pit lined filling with fire hydrate water ,started to drill hole for conductor.

Estimated cementing time 1:30 -2:00 PM

1262628486 2009-11-16 Drill / Deepen / Reopen No Violations cementing conductor pipe 113/4 to 40with 50 sacks class A cement.

(Company drilling this well while school is on Thanksgiving Break)

1269041678 2013-10-22 UrbanPreliminary Restoration No Violations The producing unit consists of a mechanical plunger lift unit and above-ground storage tank (AST) battery. The battery is comprised of 1 100-barrel steel production tank and 1 50-barrel brine tank, separator unit, and Dominion metering run. The wellhead and battery are both enclosed in separate board-on-board fences. The load-outs are bull-plugged. The ID and secondary containment are good. The unit is fitted with carbon canister, low-pressure relief valve, and spark arrestor. Gates are locked. Lease road is in good condition and areas impacted by drilling have been restored. No problems noted and passes preliminary restoration.
1308097606 2009-12-17 Drill / Deepen / Reopen No Violations service crew on site preparing to fracture well.
1349914660 2009-11-17 Drill / Deepen / Reopen No Violations BOP test passed
1411836111 2014-10-15 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead and tank battery areas are in good condition and free from signs of leakage or problems. The secondary containment is intact and free from fluids. I observed some peeling of the paint on the tanks but otherwise no problems noted. Enclosure gates are locked. The short access road from the Ratner School parking area is stable and drainage is good.
1417512898 2010-02-18 Drill / Deepen / Reopen No Violations No violations Company on site grading out topsoil which is still wet .
1502373029 2017-08-10 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate board-on-board enclosures. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of tall grasses and other vegetation, with a short, gravel-paved access road. I did not observe any signs of problems.
1517001977 2015-03-09 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. Access to the well and battery is via a short dedicated access road on the SW side of the Ratner School building. The wellhead plunger lift and battery are in separate board-on-board enclosures. At the time of my inspection, the enclosure gates are locked, load-outs are plugged, secure, and locked, and connections and fittings are secure and free from signs of leakage or other problems. At the time of this inspection, the surrounding areas are snow-covered. I did not observe any signs of impact relating to the on-going production activity at the time of this inspection.
1780265085 2017-10-10 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift and associated tank battery located on the grounds of a relious school facility. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery, and found no signs of impact or degradation attributable to the production system. The egress and ingress road was in good condition.
1941885355 2009-11-20 Drill / Deepen / Reopen No Violations walked perimeter with gas meter NO GAS DETECTED or ODORS. Checked blow line 70 to separator set up to control the flow of drill mud to pits

Drilling at 3124 Prognosis for Lockport 2993-3405 (Newburgh 3180-3187)

871272847 2009-11-17 0:00 DD No Violations

For data sources see[9]

References