34-035-22060

Well Details

Well ID: 34-035-22060
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Chagrin Falls Township
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: JACKSON
License Status: Producing
License Date: 2008-07-15
Spud Date: 2008-09-27
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-10-02
Well Total Depth: 3744.00 ft
Configuration: Vertical
Latitude: 41.430000
Longitude: -81.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-15 Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:7/15/2008, Expired Date:7/15/2009 6:00:00 AM, Drilling unit acres:34.65, Proposed Well Type:OG, Proposed Well Class:EOUT
Reached Total Depth 2008-10-02
Completion Report Received 2009-01-02
Construction Permit Expires 2009-07-15
Change of Owner 2018-08-21 Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2018-08-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-02-20 3556 3616 26
3556 3616 26
3556 3616 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 67000 Gal 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 GONZOIL INC 18486.00 283.00 365
2010 GONZOIL INC 19243.00 87.00 365
2011 GONZOIL INC 14375.00 170.00 365
2012 GONZOIL INC 12386.00 80.00 366
2013 GONZOIL INC 9805.00 0.00 365
2014 GONZOIL INC 8301.00 85.00 365
2015 GONZOIL INC 6952.00 0.00 365
2016 GONZOIL INC 6484.00 75.00 365
2017 GONZOIL INC 7116.00 33.00 365
2018 PIN OAK ENERGY PARTNERS LLC 1138.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 GONZOIL INC Brine 378 365
2010 GONZOIL INC Brine 245 365
2011 GONZOIL INC Brine 130 365
2012 GONZOIL INC Brine 135 366
2013 GONZOIL INC Brine 120 365
2014 GONZOIL INC Brine 40 365
2015 GONZOIL INC Brine 0 365
2016 GONZOIL INC Brine 0 365
2017 GONZOIL INC Brine 75 365
2018 GONZOIL INC Brine 0 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1001420862 2008-9-27 0:00: DD No Violations
-1248925114 2017-7-7 0:00:0 UP No Violations 1.00
-152273984 2008-10-1 0:00: DD No Violations
-1670174437 2008-9-28 0:00: DD No Violations
0152273984 2008-10-01 Drill / Deepen / Reopen No Violations Drilling approx 3600 No violation found , fences up (pit,silt), no off site run off.
0247480513 2008-10-02 Drill / Deepen / Reopen No Violations company (Doug Gonzilus) called to say the rig has TD and 4.5 casing to be run and cemented tonight
0661821541 2008-09-26 Drill / Deepen / Reopen No Violations Rig move to location on Saturday morning.
1001420862 2008-09-27 Drill / Deepen / Reopen No Violations arrived on site for 11 3/4 conductor cement job.
1225718900 2008-09-24 Drill / Deepen / Reopen No Violations Doug Gonzalus Called to say location is made and He also made calls made to city.
1231168733 2008-11-03 Drill / Deepen / Reopen No Violations area levaled tanks on site not set
1248925114 2017-07-07 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead plunger lift and battery are in separate board-on-board enclosures which were locked and secure. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. The secondary containment was intact. I walked the areas around the wellhead and battery and found no observable signs of impact to the natural greenscape.
1373300319 2013-07-08 UrbanPreliminary Restoration No Violations The producing unit consists of a an above-ground storage tank (AST) battery with 1 140-barrel steel production tank, and 1 50-barrel poly brine tank, a mechanical separator, and metering run. Identification is present. There is an earthen secondary containment which is in good condition. The load-outs are bull-plugged and locked. Safety equipment is present. The wellhead is located 50 feet southwest of the battery. The wellhead consists of a mechanical plunger lift system and associated valve-tree. The annulus is plumbed into the production line. The wellhead and battery are in separate board-on-board enclosures which are locked. The lease road is paved with mixed, coarse limestone aggregate. I did not observe any problems or violations. Preliminary restoration passes.
1425048385 2015-02-27 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located in a small clearing in a mostly wooded area. The wellhead plunger lift and battery are in separate board-on-board enclosures which are locked. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. Process safety gear is present. Signage is in place and current. At the time of this inspection there are 15 to 20 inches of snow cover in the area which obscures some surficial elements from observation.
1670174437 2008-09-28 Drill / Deepen / Reopen No Violations 85/8 casing was cemented on Sunday night
2100873198 2008-10-09 Drill / Deepen / Reopen No Violations Doug Gonzoilus. called to infome me pits are to be soildified.
247480513 2008-10-2 0:00: DD No Violations
661821541 2008-9-26 0:00: DD No Violations

For data sources see[9]