X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-005-20805"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-005-20805
 
| Well ID: 34-005-20805
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.73753909, -82.29729244 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.738003685, -82.29792039 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Ashland County, Ohio|Ashland]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 
|-
 
|-
| Operator Name: [[COLUMBIA GAS TRANSMISSION]]
+
| County: [[Ashland_County,_Ohio|Ashland]]
 +
|-
 +
| Municipality: Vermilion Township
 +
|-
 +
| Operator Name: [[COLUMBIA GAS TRANSMISSION LLC]]
 
|-
 
|-
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: MCCLURE WM S
 
|-
 
|-
| First Permit Date:  
+
| License Status: Storage Well
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 2009-10-26
 
|-
 
|-
 
| Spud Date: 1952-10-01
 
| Spud Date: 1952-10-01
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor: [[CO TOOLS]]
 +
|-
 +
| Final Drill Date: 1952-11-04
 +
|-
 +
| Well Total Depth: 2699 ft
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Well Status: Storage Well
+
| Latitude: 40.738003685
 +
|-
 +
| Longitude: -82.29792039
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 
|-
 
|-
| Violations: 0
+
| Original Spud
 +
| 1952-10-01
 +
 
|-
 
|-
| Latitude: 40.73753909
+
| Completed
 +
| 1952-11-04
 +
 
|-
 
|-
| Longitude: -82.29729244
+
| Reached Total Depth
 +
| 1952-11-04
 +
 +
|-
 +
| Record Last Modified
 +
| 2013-05-23
 +
 
|-
 
|-
 
|}
 
|}
== Inspection Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 +
|-
 +
|}-->
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
== Stimulations Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Stimulation Date
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Chemical Agent
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Fracking Fluid Volume
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
!scope="col" | VIOLATION CODE
+
!scope="col" style="text-align: center"| Fracking Company
!scope="col" | VIOLATION COMMENT
+
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
| -165129680
 
| 2013-12-19
 
 
|  
 
|  
| Gas is venting through the line to the poly tank from the drip.  ID posted.
 
 
|  
 
|  
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 
|  
 
|  
 
|  
 
|  
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblStimulation Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
|}-->
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Inspection Date
 +
!scope="col" style="text-align: center"| Inspection Type
 +
!scope="col" style="text-align: center"| Inspection Result
 +
!scope="col" style="text-align: center"| Inspection Comments
 
|-
 
|-
| -1910055150
+
| 0165129680
 +
| 2013-12-19
 +
| Storage Well
 +
| No Violations
 +
| Gas is venting through the line to the poly tank from the drip.  ID posted.
 +
|-
 +
| 0702411929
 +
| 2017-07-13
 +
| Storage Well
 +
| No Violations
 +
| ID is posted and the location is maintained.  The gate valve and annulus are open.  The well is equipped with a separator.  There is a 5 barrel tank connected to the separator.
 +
|-
 +
| 1052320493
 +
| 2016-10-19
 +
| Storage Well
 +
| No Violations
 +
| ID is posted and the location is maintained.  The gate valve and annulus are open.  There is a 5 barrel tank connected to the separator.  The welltender repaired a valve on the line from the separator to the tank during inspection.
 +
|-
 +
| 1264572892
 +
| 2015-10-19
 +
| Storage Well
 +
| No Violations
 +
| ID is posted and the location is maintained.  The well is shut in at the gate valve; the annulus is open.  There is a 5 barrel tank at the well.
 +
|-
 +
| 1729089896
 +
| 2019-04-09
 +
| Storage Well
 +
| No Violations
 +
| Performed annual inspection for Columbia Gas Storage Well #9135 on 04/09/2019.  The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-210 gal plastic tank.  Well identification is clearly displayed.  The well is located ~260 from its RBDMS location.  A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz (DOGRM Columbus).  No other problems were noted at the time of the inspection.
 +
|-
 +
| 1910055150
 
| 2014-10-16
 
| 2014-10-16
|  
+
| Storage Well
 +
| No Violations
 
| ID posted, location maintained.
 
| ID posted, location maintained.
|  
+
|-
|  
+
| 1990361666
|  
+
| 2018-10-01
 +
| Storage Well
 +
| No Violations
 +
| ID is posted and the location is maintained.  The annulus is open.  There is a 5 barrel tank connected to the separator.
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Revision as of 14:52, 24 July 2019

Well Details

Well ID: 34-005-20805
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Vermilion Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: MCCLURE WM S
License Status: Storage Well
License Date: 2009-10-26
Spud Date: 1952-10-01
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1952-11-04
Well Total Depth: 2699 ft
Configuration: Vertical
Latitude: 40.738003685
Longitude: -82.29792039

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1952-10-01
Completed 1952-11-04
Reached Total Depth 1952-11-04
Record Last Modified 2013-05-23

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0165129680 2013-12-19 Storage Well No Violations Gas is venting through the line to the poly tank from the drip. ID posted.
0702411929 2017-07-13 Storage Well No Violations ID is posted and the location is maintained. The gate valve and annulus are open. The well is equipped with a separator. There is a 5 barrel tank connected to the separator.
1052320493 2016-10-19 Storage Well No Violations ID is posted and the location is maintained. The gate valve and annulus are open. There is a 5 barrel tank connected to the separator. The welltender repaired a valve on the line from the separator to the tank during inspection.
1264572892 2015-10-19 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. There is a 5 barrel tank at the well.
1729089896 2019-04-09 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #9135 on 04/09/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-210 gal plastic tank. Well identification is clearly displayed. The well is located ~260 from its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection.
1910055150 2014-10-16 Storage Well No Violations ID posted, location maintained.
1990361666 2018-10-01 Storage Well No Violations ID is posted and the location is maintained. The annulus is open. There is a 5 barrel tank connected to the separator.