If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-019-22737 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.645351086,"lon":-81.0977706,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Harrison Township | |
Operator Name: PENNENERGY RESOURCES LLC | |
Well Pad ID: US-OH-001487 | |
Farm/Lease Name: GOEBELER UNIT | |
License Status: Producing | |
License Date: 2017-07-25 | |
Spud Date: 2017-08-10 | |
Spud Drilling Contractor: SIDEWINDER DRILLING INC | |
Final Drill Date: 2017-10-24 | |
Well Total Depth: 15763 ft | |
Configuration: Horizontal | |
Latitude: 40.645351086 | |
Longitude: -81.09777060 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-07-25 | Proposed Formations:UTICA/POINT PLEASANT, Issued Date:7/25/2017, Expired Date:7/25/2019 12:00:00 PM, Drilling unit acres:179.3, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2017-10-24 | Baker Hughes ran directional survey OP REQUEST 1 YEAR CONFIDENTIALITY ALL LOGS |
Change of Owner | 2018-10-03 | Operator changed from 8894, R E GAS DEVELOPMENT LLC to 10212, PENNENERGY RESOURCES LLC |
Completion Report Received | 2019-01-08 | Baker Hughes ran directional survey OP REQUEST 1 YEAR CONFIDENTIALITY ALL LOGS |
Record Last Modified | 2019-01-10 | Baker Hughes ran directional survey OP REQUEST 1 YEAR CONFIDENTIALITY ALL LOGS |
Construction Permit Expires | 2019-07-25 | Baker Hughes ran directional survey OP REQUEST 1 YEAR CONFIDENTIALITY ALL LOGS |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2018-04-25 | 8138 | 8295 | 55 |
2018-04-25 | 15508 | 15692 | 55 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 01/26/2018 | 02/28/2018 | 7355 | 15,854,000.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | 4.0 Guar Slurry | ProFrac | Proppant Transport | Guar Gum | 9000-30-0 | 55 | 0.0499457 | 75982 |
Distillates (petroleum), hydrotreated light | 64742-47-8 | 45 | 0.0408646 | 62167 | ||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | 4-Methoxyphenol | 150-76-5 | 0 | 0 | 0 | |
Citric Acid | 77-92-9 | 40 | 0.00290608 | 4421 | ||||
Ammonium Chloride | 12125-02-9 | 1 | 0.000218893 | 333 | ||||
Ethanol | 64-17-5 | 2 | 0.000541645 | 824 | ||||
Water | 7732-18-5 | 75 | 0.0164058 | 24958 | ||||
Alcohols C12-14 ethoxylated | 68439-50-9 | 3.6 | 0.00131533 | 2001 | ||||
Copolymer of 2-Propenamide | 69418-26-4 | 30 | 0.0148939 | 22658 | ||||
Water | 7732-18-5 | 85 | 0.0171558 | 26099 | ||||
Hydrochloric Acid (Hydrogen Chloride) | 7647-01-0 | 28 | 0.565133 | 859732 | ||||
Alkyl Quaternary Compound | 7173-51-5 | 1.2 | 0.000324724 | 494 | ||||
Glutaraldehyde | 111-30-8 | 12.5 | 0.00338594 | 5151 | ||||
Organophosphonate | 129828-36-0 | 15 | 0.00328142 | 4992 | ||||
Oleic Acid Diethanolamide | 93-83-4 | 3 | 0.00148952 | 2266 | ||||
Ethylenediamineteraacetate, sodium salt | 64-02-8 | 0.1 | 0 | 0 | ||||
Alcohols C10-16 | 68002-97-1 | 3.6 | 0.00131533 | 2001 | ||||
Alcohol Ethoxylate Surfactants | 68551-12-2 | 3 | 0.00148952 | 2266 | ||||
Quarternary Ammonium Compound | 68424-85-1 | 1.8 | 0.000487086 | 741 | ||||
Ammonium acetate | 631-61-8 | 10 | 0.00365282 | 5557 | ||||
Sodium Chloride | 7647-14-5 | 10 | 0.00496486 | 7553 | ||||
Hydrotreated Petroleum Distillate | 64742-47-8 | 25 | 0.0124118 | 18882 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 45 | 0.0408646 | 62167 | ||||
Alcohols C12-16 ethoxylated | 68551-12-2 | 3.6 | 0.00131533 | 2001 | ||||
Sulphamic Acid | 5329-14-6 | 5 | 0.000363507 | 553 | ||||
Ammonium Chloride | 12125-02-9 | 2 | 0.000993234 | 1511 | ||||
Polyoxyethylene Sorbitan Monooleate | 9005-65-6 | 1 | 0.000496288 | 755 | ||||
Alpha 123 | Baker Hughes | Biocide | Water | 7732-18-5 | 82.5 | 0.0223468 | 33996 | |
Alkyl Quaternary Compound | 7173-51-5 | 1.2 | 0.000324724 | 494 | ||||
Glutaraldehyde | 111-30-8 | 12.5 | 0.00338594 | 5151 | ||||
Ethanol | 64-17-5 | 2 | 0.000541645 | 824 | ||||
Quarternary Ammonium Compound | 68424-85-1 | 1.8 | 0.000487086 | 741 | ||||
ProFE 105 | ProFrac | Iron Control | Citric Acid | 77-92-9 | 40 | 0.00290608 | 4421 | |
Sulphamic Acid | 5329-14-6 | 5 | 0.000363507 | 553 | ||||
Water | 7732-18-5 | 70 | 0.00508646 | 7738 | ||||
Sand | ProFrac | Proppant | Silica Substrate | 14808-60-7 | 100 | 10.7553 | 16,362,000.0 | |
Hydrochloric Acid (10%) | Cooper Natural | Acidizing | Water | 7732-18-5 | 72 | 1.4532 | 2,210,740.0 | |
Hydrochloric Acid (Hydrogen Chloride) | 7647-01-0 | 28 | 0.565133 | 859732 | ||||
FR 9400 | StimStream | Friction Reducer | Alcohols C10-16 | 68002-97-1 | 3.6 | 0.00131533 | 2001 | |
Ammonium acetate | 631-61-8 | 10 | 0.00365282 | 5557 | ||||
Alcohols C12-14 ethoxylated | 68439-50-9 | 3.6 | 0.00131533 | 2001 | ||||
Alcohols C12-16 ethoxylated | 68551-12-2 | 3.6 | 0.00131533 | 2001 | ||||
Distillates (petroleum), hydrotreated light | 64742-47-8 | 25 | 0.00913237 | 13893 | ||||
Water | Rex Energy | Carrier/Base | Water | 7732-18-5 | 100 | 86.9668 | 132,302,000.0 | |
Scaletrol 767W | Baker Hughes | Biocide | Organophosphonate | 129828-36-0 | 15 | 0.00328142 | 4992 | |
Methanol | 67-56-1 | 30 | 0.00656218 | 9983 | ||||
Ammonium Chloride | 12125-02-9 | 1 | 0.000218893 | 333 | ||||
Water | 7732-18-5 | 75 | 0.0164058 | 24958 | ||||
ProHib 100 | ProFrac | Acid Inhibitor | 2-Polyn-1-ol compound w/ methyloxirane | 38172-91-7 | 15 | 0.00302769 | 4606 | |
Water | 7732-18-5 | 85 | 0.0171558 | 26099 | ||||
FR 7005 | ECM | Friction Reducer | Polyoxyethylene Sorbitan Monooleate | 9005-65-6 | 1 | 0.000496288 | 755 | |
Ammonium Chloride | 12125-02-9 | 2 | 0.000993234 | 1511 | ||||
Oleic Acid Diethanolamide | 93-83-4 | 3 | 0.00148952 | 2266 | ||||
Hydrotreated Petroleum Distillate | 64742-47-8 | 25 | 0.0124118 | 18882 | ||||
Copolymer of 2-Propenamide | 69418-26-4 | 30 | 0.0148939 | 22658 | ||||
Sodium Chloride | 7647-14-5 | 10 | 0.00496486 | 7553 | ||||
Water | 7732-18-5 | 50 | 0.024823 | 37763 | ||||
Alcohol Ethoxylate Surfactants | 68551-12-2 | 3 | 0.00148952 | 2266 | ||||
ProBreak 100 | ProFrac | Oxidizer | Ammonium Persulfate | 7727-54-0 | 100 | 0.000747391 | 1137 |
For data sources see[4]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2018-01-25 | H2O | 10 | 10886 Bbl | 240380 | PRO FRAC | STAGE 1/45
STAGES 2-44 SEE IMAGES |
2018-02-27 | H2O | 10 | 6937 Bbl | 372780 | PRO FRAC | STAGE 45/45
STAGES 2-44 SEE IMAGES |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2018 | PENNENERGY RESOURCES LLC | 447675 | 51025 | 267 |
2019 | PENNENERGY RESOURCES LLC | 110128 | 13106 | 89 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2018 | PENNENERGY RESOURCES LLC | Brine | 27988 | 267 |
2019 | PENNENERGY RESOURCES LLC | Brine | 3516 | 89 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0071174977 | 2018-01-10 | Drill / Deepen / Reopen | No Violations | I was on site to check the status of the pad. Schlumberger was on site running wireline logs, and a10k frac valve had been installed all seven wells. I spoke to the consultant on site, who anticipates completion activities to commence by the end of January. |
0423494240 | 2018-06-30 | Production Wells | No Violations
-around inspection of the pad perimeter and erosional controls appeared functioning. Production equipment consisted of the following: - 400 bbl production tanks, nine labeled as containing condensate, and nine as containing produced water Three vapor recovery units Four oil stabilization units with towers and vertical separators Ten gas processing units with vertical separators Seven combustor units I did not locate a surface-intermediate annular pressure gauge. I contacted operator who stated they in the process of acquiring gauges from the supplier and an annular gauge will be installed as soon as possible. | |
0489574728 | 2017-11-17 | Drill / Deepen / Reopen | No Violations | I was on site during drilling operations. Sidewinder #62 was the drilling operator, and was drilling the 8.75 tangent section at a depth of 5350 and at approximately 200 ft/hr. I spoke to the consultant on site who informed me that no hole issues have been encountered during drilling. |
0864289612 | 2017-09-21 | Drill / Deepen / Reopen | No Violations | I was on site to check the drilling status of the pad. Sidewinder #62 was currently moving equipment on site and was anticipated to resume drilling operations this week. I performed a walk-around inspection of the site and no violations were noted at the time of inspection. |
0905999191 | 2018-04-25 | Completion Testing | No Violations | I was on site during flow back operations of the pad which started on 04/20/2018. Two stacks were actively flaring on the pad. I did not receive notification of flow back and subsequent flaring. I contacted Derek Smith of R.E. Gas Development and discussed notification requirements of flaring and informed the company that failure to do so in the future will result in enforcement action. |
1286823114 | 2017-08-14 | Drill / Deepen / Reopen | No Violations | I was on site with DOGRM Steve Ochs. The Yost#8 rig was in the process of being moved on site to drill the surface and intermediate sections of the seven permitted wells on the Goebeler B pad. We had a pre-spud meeting with Aaron Wilhite, the Rex consultant on site. Talking points included casing points and notifications. No violations were noted while at the time of inspection. |
1502382307 | 2017-08-09 | Drill / Deepen / Reopen | No Violations | |
1503539240 | 2017-08-23 | Drill / Deepen / Reopen | No Violations
-around inspection of the rig while on site, and no violations were found at the time of inspection. | |
1516216022 | 2018-01-04 | Drill / Deepen / Reopen | No Violations | I conducted a status check of the pad while the operator was in preparations to complete the well. Stacks were being set on the well while I was on site. I spoke to the consultant from Rex, who informed me that pressure testing for the well will take place during the weekend of 01/06/2018. I performed a walk-around inspection of the site and no violations were observed at the time of inspection. |
1761763048 | 2018-01-16 | Drill / Deepen / Reopen | No Violations | I was on site to pick up a copy of the bond logs ran on the seven Goebeler wells drilling during 2017. Rex was in the process of installing isolation valves on the stacks. I spoke to the company man who anticipated completion operations to commence during the week of 1/21/18. I performed a walk-around inspection of the pad and no violations were observed during the time of inspection. |
1882003943 | 2017-09-13 | Drill / Deepen / Reopen | No Violations | |
1957025821 | 2018-02-15 | Drill / Deepen / Reopen | No Violations | I was on site during completion operations. I performed a walk-around inspection of the site and no violations were observed at the time of inspection. |
For data sources see[10]