37-035-21174

Well Details

Well ID: 37-035-21174
Loading map...
Country: United States
State: Pennsylvania
County: Clinton
Municipality: Beech Creek Township
Operator Name: ARD OPR LLC
Well Pad ID: 148083
Farm/Lease Name: COP TRACT 653 B 1005H
License Status: Active
Spud Date: 2010-05-14
Permit Date: 2009-07-29
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.196696
Longitude: -77.683025

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 0.00 0 0.00 0 0.00 0
2010 ANADARKO E&P ONSHORE LLC 307,186.00 92 0.00 0 0.00 0
2011 ANADARKO E&P ONSHORE LLC 696,693.00 365 0.00 0 0.00 0
2012 ANADARKO E&P ONSHORE LLC 409,584.00 269 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 382,577.00 327 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 297,961.00 324 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 85,416.00 113 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 350,512.00 309 0.00 0 0.00 0
2017 ANADARKO E&P ONSHORE LLC 248,138.74 352 0.00 0 0.00 0
2018 ARD OPR LLC 210,222.99 324 0.00 0 0.00 0
2019 ARD OPR LLC 63,680.49 84 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-A01 Drilling Fluid Waste (in Barrels) 321.00 Bbl IDENTIFY METHOD IN COMMENTS
2010-S01 Drilling Fluid Waste (in Barrels) 160.50 Bbl IDENTIFY METHOD IN COMMENTS
2011-S01 Drill Cuttings (in Tons) 42.09 Tons LANDFILL 101397
2012-S02 Produced Fluid (in Barrels) 469.13 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S01 Produced Fluid (in Barrels) 884.33 Bbl REUSE OTHER THAN ROAD SPREADING
2013-S02 Produced Fluid (in Barrels) 331.40 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 577.57 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 453.21 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 1,034.13 Bbl REUSE OTHER THAN ROAD SPREADING
2016-M10 Produced Fluid (in Barrels) RWC 802 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016-M11 Produced Fluid (in Barrels) RWC 802 86.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016-M12 Produced Fluid (in Barrels) RWC 802 71.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016-S01 Produced Fluid (in Barrels) RWC 802 300.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016-S02 Produced Fluid (in Barrels) RWC 802 258.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2017-M01 Produced Fluid (in Barrels) RWC 802 71.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M05 Produced Fluid (in Barrels) RWC 802 81.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017-M12 Produced Fluid (in Barrels) RWC 802 49.63 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 24.00 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 27.88 Bbl REUSE (AT WELL PAD)
2018-M10 Drilling Fluid Waste (in Barrels) RWC 803 54.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-M10 Produced Fluid (in Barrels) RWC 802 54.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1895694 Primary Facility 2010-06-30 Drilling/Alteration No Violations Noted Precision 531 was tripping in to drill out 13 3/8" plug. Broke hydraulic hose, on down time.
1914151 Primary Facility 2010-09-17 Routine/Complete Inspection No Violations Noted Bobcat on location with coil tubing rigged up, but not currently connected to well. Frac tanks on location.
1920088 Primary Facility 2010-10-15 Routine/Partial Inspection No Violations Noted
1941582 Primary Facility 2011-01-07 Routine/Partial Inspection Violation(s) Noted No well tag, pit fence fallen down around half of pit, hose with flowback on ground with discharge to soil
1963694 Primary Facility 2011-04-06 Follow-up Inspection No Violations Noted
2039705 Primary Facility 2012-01-04 Routine/Complete Inspection No Violations Noted
2104439 Primary Facility 2012-09-11 Routine/Complete Inspection No Violations Noted
2182918 Primary Facility 2013-07-12 Routine/Complete Inspection No Violations Noted
2313830 Primary Facility 2014-10-17 Routine/Complete Inspection No Violations Noted
2629514 Primary Facility 2017-08-23 Routine/Complete Inspection No Violations Noted Routine inspection of of ARD Operating LLC's COP TRACT 653 Pads B&C on August 24, 2017. No one was onsite during my inspection. This ESCGP (ESG29-035-16-0001) covers both Marcellus well pads B&C.

Pad B: There are two active Marcellus wells on this pad (035-21162 and 035-21174). Each well is tagged with the permit number. Both cellars are full of water. Each well is plumbed to its own production unit. In addition there are (3) 400 BBL produced fluids tanks located in secondary containment. No water was observed within the containment.

Pad C: There are three active Marcellus wells on this pad (035-21161, 035-21264, and 035-21273). Each well is tagged with the permit number. All cellars were full of water. Each well is plumbed to its own production unit. In addition there are (4) 400 BBL produced fluids tanks stationed in secondary containment. Just a trace of water was observed within the containment.

Vegetation exceeds 70% around both well pads and both pads appear stable. No PCSMs were observed at eithe

2806204 Primary Facility 2018-11-20 Routine/Complete Inspection No Violations Noted On November 5, 2018, Department representative Brad Kline conducted a routine site inspection at ARD Operating , LLC. COP Tract 653 Pad B. Temporary E&S controls and site restoration could not be evaluated due to snow cover. ESG29-035-16-0001 covers both Pad B and Pad C in the permit.

There are a total of 2 producing wells located on this well pad. All wells are tagged with API/well permit numbers. No bubbling within the cellars was observed. There are 2 GPU’s and 2 steel vertical production fluids tanks onsite. Both GPUs and production fluid tanks were stationed in secondary containment. The steel production fluid tanks had some minor corrosion occurring (Photo 3). The Department recommends monitoring the condition of the tanks.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1941582 602605 01/07/2011 2011-01-07 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative
1941582 602606 01/07/2011 2011-01-07 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. Administrative
1941582 602607 01/07/2011 2011-01-07 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative 78.56(a)
1941582 602608 01/07/2011 2011-01-07 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
1941582 602609 01/07/2011 2011-01-07 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
602605 266967 NOV - Notice of Violation Comply/Closed 2011-04-06
602606 266967 NOV - Notice of Violation Comply/Closed 2011-04-06
602607 266967 NOV - Notice of Violation Comply/Closed 2011-04-06
602608 266967 NOV - Notice of Violation Comply/Closed 2011-04-06
602609 266967 NOV - Notice of Violation Comply/Closed 2011-04-06

For data sources see[6]