Well History

Date Event
2009-07-29 New Permit Application
2010-05-14 Performed Spud Operation
2010-07-23 Drilling Completion
2010-09-03 Perforation
2011-01-21 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2010 ANADARKO E&P ONSHORE LLC 307,186.00 92 0.00 0 0.00 0
2011 ANADARKO E&P ONSHORE LLC 696,693.00 365 0.00 0 0.00 0
2012 ANADARKO E&P ONSHORE LLC 409,584.00 269 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 382,577.00 327 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 297,961.00 324 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 85,416.00 113 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 350,512.00 309 0.00 0 0.00 0
2017 ARD OPR LLC 248,138.74 352 0.00 0 0.00 0
2018 ARD OPR LLC 210,222.99 324 0.00 0 0.00 0
2019 ARD OPR LLC 217,603.20 355 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 ANADARKO E&P ONSHORE LLC Drilling Fluid Waste 160.50 Bbl IDENTIFY METHOD IN COMMENTS
2011 ANADARKO E&P ONSHORE LLC Drill Cuttings 42.09 Tons LANDFILL 101397
2012 ANADARKO E&P ONSHORE LLC Produced Fluid 469.13 Bbl REUSE OTHER THAN ROAD SPREADING
2013 ANADARKO E&P ONSHORE LLC Produced Fluid 1,215.73 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ANADARKO E&P ONSHORE LLC Produced Fluid 1,030.78 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 1,034.13 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 71.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 86.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 258.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 300.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 71.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 ARD OPR LLC Produced Fluid 49.63 Bbl REUSE (AT WELL PAD)
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 81.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 ARD OPR LLC Drilling Fluid Waste 54.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 ARD OPR LLC Produced Fluid 51.88 Bbl REUSE (AT WELL PAD)
2018 ARD OPR LLC Produced Fluid 54.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 ARD OPR LLC Produced Fluid 19.18 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1895694 Primary Facility 2010-06-30 Drilling/Alteration No Violations Noted Precision 531 was tripping in to drill out 13 3/8" plug. Broke hydraulic hose, on down time.
1914151 Primary Facility 2010-09-17 Routine/Complete Inspection No Violations Noted Bobcat on location with coil tubing rigged up, but not currently connected to well. Frac tanks on location.
1920088 Primary Facility 2010-10-15 Routine/Partial Inspection No Violations Noted
1941582 Primary Facility 2011-01-07 Routine/Partial Inspection Violation(s) Noted No well tag, pit fence fallen down around half of pit, hose with flowback on ground with discharge to soil
1963694 Primary Facility 2011-04-06 Follow-up Inspection No Violations Noted
2039705 Primary Facility 2012-01-04 Routine/Complete Inspection No Violations Noted
2104439 Primary Facility 2012-09-11 Routine/Complete Inspection No Violations Noted
2182918 Primary Facility 2013-07-12 Routine/Complete Inspection No Violations Noted
2313830 Primary Facility 2014-10-17 Routine/Complete Inspection No Violations Noted
2629514 Primary Facility 2017-08-23 Routine/Complete Inspection No Violations Noted Routine inspection of of ARD Operating LLC's COP TRACT 653 Pads B&C on August 24, 2017. No one was onsite during my inspection. This ESCGP (ESG29-035-16-0001) covers both Marcellus well pads B&C.

Pad B: There are two active Marcellus wells on this pad (035-21162 and 035-21174). Each well is tagged with the permit number. Both cellars are full of water. Each well is plumbed to its own production unit. In addition there are (3) 400 BBL produced fluids tanks located in secondary containment. No water was observed within the containment.

Pad C: There are three active Marcellus wells on this pad (035-21161, 035-21264, and 035-21273). Each well is tagged with the permit number. All cellars were full of water. Each well is plumbed to its own production unit. In addition there are (4) 400 BBL produced fluids tanks stationed in secondary containment. Just a trace of water was observed within the containment.

Vegetation exceeds 70% around both well pads and both pads appear stable. No PCSMs were observed at eithe

2806204 Primary Facility 2018-11-20 Routine/Complete Inspection No Violations Noted On November 5, 2018, Department representative Brad Kline conducted a routine site inspection at ARD Operating , LLC. COP Tract 653 Pad B. Temporary E&S controls and site restoration could not be evaluated due to snow cover. ESG29-035-16-0001 covers both Pad B and Pad C in the permit.

There are a total of 2 producing wells located on this well pad. All wells are tagged with API/well permit numbers. No bubbling within the cellars was observed. There are 2 GPU’s and 2 steel vertical production fluids tanks onsite. Both GPUs and production fluid tanks were stationed in secondary containment. The steel production fluid tanks had some minor corrosion occurring (Photo 3). The Department recommends monitoring the condition of the tanks.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1941582 602605 01/07/2011 2011-01-07 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative
1941582 602606 01/07/2011 2011-01-07 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. Administrative
1941582 602607 01/07/2011 2011-01-07 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative 78.56(a)
1941582 602608 01/07/2011 2011-01-07 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
1941582 602609 01/07/2011 2011-01-07 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
602605 266967 NOV - Notice of Violation Comply/Closed 2011-04-06
602606 266967 NOV - Notice of Violation Comply/Closed 2011-04-06
602607 266967 NOV - Notice of Violation Comply/Closed 2011-04-06
602608 266967 NOV - Notice of Violation Comply/Closed 2011-04-06
602609 266967 NOV - Notice of Violation Comply/Closed 2011-04-06

For data sources see[7]