34-099-22930

Well Details

Well ID: 34-099-22930
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Boardman Township
Operator Name: OHIO VALLEY ENERGY SYSTEM CORP
Well Pad ID:
Farm/Lease Name: LOCKWOOD UNIT
License Status: Producing
License Date: 2003-01-29
Spud Date: 2002-08-07
Spud Drilling Contractor: LANDOGS DRILLING
Final Drill Date: 2002-08-14
Well Total Depth: 5726 ft
Configuration: Directional
Latitude: 41.027006725
Longitude: -80.71064512

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2002-07-29 Proposed Formations:CLINTON, Issued Date:7/29/2002, Expired Date:7/29/2003 6:00:00 AM, Drilling unit acres:42.76, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2002-08-07 Surface hole drilled on fluid to 200'. Remainder of surface hole drilled on air. No problems encountered. Show of gas in the Berea. Pits lined. Good cemenet returns.
Completed 2002-08-14 Surface hole drilled on fluid to 200'. Remainder of surface hole drilled on air. No problems encountered. Show of gas in the Berea. Pits lined. Good cemenet returns.
Reached Total Depth 2002-08-14 Surface hole drilled on fluid to 200'. Remainder of surface hole drilled on air. No problems encountered. Show of gas in the Berea. Pits lined. Good cemenet returns.
Correction to Well 2002-08-23 ADDED TARGET INFORMATION: 932'SL & 780'EL OF LOT 21, CANFIELD TWP.; X= 2,492,799 AND Y= 500,744.
Completion Report Received 2002-09-09 Surface hole drilled on fluid to 200'. Remainder of surface hole drilled on air. No problems encountered. Show of gas in the Berea. Pits lined. Good cemenet returns.
Correction to Well 2003-03-28 CORRECTION TO LOCATION INFORMATION: 999'SL & 840'EL OF LOT 21,DIV. 3 (E), CANFIELD TWP. X= 2,492,739 AND Y= 500,817.
Construction Permit Expires 2003-07-29 Surface hole drilled on fluid to 200'. Remainder of surface hole drilled on air. No problems encountered. Show of gas in the Berea. Pits lined. Good cemenet returns.
Record Last Modified 2017-02-15 Surface hole drilled on fluid to 200'. Remainder of surface hole drilled on air. No problems encountered. Show of gas in the Berea. Pits lined. Good cemenet returns.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2002-10-22 5476 5520 88

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2750 Bbl 80000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 OHIO VALLEY ENERGY SYSTEM CORP 39972 87 295
2004 OHIO VALLEY ENERGY SYSTEM CORP 25307 58 364
2005 OHIO VALLEY ENERGY SYSTEM CORP 18056 38 336
2006 OHIO VALLEY ENERGY SYSTEM CORP 12553 0 364
2007 OHIO VALLEY ENERGY SYSTEM CORP 14774 0 364
2008 OHIO VALLEY ENERGY SYSTEM CORP 17008 53 365
2009 OHIO VALLEY ENERGY SYSTEM CORP 11283 0 365
2010 OHIO VALLEY ENERGY SYSTEM CORP 10905 0 365
2011 OHIO VALLEY ENERGY SYSTEM CORP 7714 0 365
2012 OHIO VALLEY ENERGY SYSTEM CORP 11236 0 366
2013 OHIO VALLEY ENERGY SYSTEM CORP 8758 0 365
2014 OHIO VALLEY ENERGY SYSTEM CORP 7429 0 365
2015 OHIO VALLEY ENERGY SYSTEM CORP 7595 0 365
2016 OHIO VALLEY ENERGY SYSTEM CORP 6999 0 365
2017 OHIO VALLEY ENERGY SYSTEM CORP 6813 0 365
2018 OHIO VALLEY ENERGY SYSTEM CORP 6542 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 OHIO VALLEY ENERGY SYSTEM CORP Brine 139 295
2004 OHIO VALLEY ENERGY SYSTEM CORP Brine 31 364
2005 OHIO VALLEY ENERGY SYSTEM CORP Brine 86 336
2006 OHIO VALLEY ENERGY SYSTEM CORP Brine 54 364
2007 OHIO VALLEY ENERGY SYSTEM CORP Brine 35 364
2008 OHIO VALLEY ENERGY SYSTEM CORP Brine 47 365
2009 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365
2010 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365
2011 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365
2012 OHIO VALLEY ENERGY SYSTEM CORP Brine 69 366
2013 OHIO VALLEY ENERGY SYSTEM CORP Brine 60 365
2014 OHIO VALLEY ENERGY SYSTEM CORP Brine 42 365
2015 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365
2016 OHIO VALLEY ENERGY SYSTEM CORP Brine 36 365
2017 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
001216i979 2002-10-18 Preliminary Restoration No Violations Pits closed.
0089877686 2002-08-29 Preliminary Restoration No Violations Pits are now closed.
1130182546 2003-06-04 Preliminary Restoration No Violations Meets requirements for preliminary restoration. There is a dike, 1-100bbl and 1-separator.
1140708046 2007-05-03 Production Wells No Violations This inspection was due to the Boardman Township Fire Departments request. Well and tank battery were GPSd Pine trees surround the tank battery. ID sign was posted. No violations at this time
1328902096 2012-02-07 UrbanProduction Wells No Violations I conducted a status check on this site and found that the well head was fenced with chain link, and it is equipped with a plunger lift system. The tank battery consists of one 100 barrel stock tank equipped with flash arrestor and charcoal filter, and one separator, no brine storage tank present. The thief hatch was closed and there was a bull plug installed in the draw valve. The tank battery was fenced with chain link, and the dike was free of vegetation and debris. Proper identification was posted, and I found no leaks or spills at the well head or tank battery. I took new GPS coordinates of the well head and tank battery. No violations at this time.
1356366439 2012-12-19 Production Wells No Violations On 12/19/2012, I performed a status check on the above location. The tank battery consist of one 140 barrel tank, one horizontal separator. The well is a 1.5 plunger lift. I D. signs are posted, dike is in good condition. No violations were noticed at this time.
1705791064 2010-10-13 Preliminary Restoration No Violations I performed a random field inspection. I GPSd both the tank battery and the wellhead. I continued to walk around both the wellhead and the tank battery. This inspection satisfies 1501:9-9-05. There were no violations at this time.

For data sources see[9]