{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.65200263,"lon":-81.22126639,"icon":""}]} |
County: Lake | |
Municipality: | |
Operator Name: OSAIR INC | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 2008-12-03 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Producing | |
Violations: 0 | |
Latitude: 41.65200263 | |
Longitude: -81.22126639 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2009-0 | 10031.0 | 0.0 | ||||
2010-0 | 5048.0 | 51.0 | ||||
2011-0 | 3607.0 | 17.0 | ||||
2012-0 | 5433.0 | 0.0 | ||||
2013-0 | 4623.0 | 0.0 | ||||
2014-0 | 5341.0 | 365.0 | 0.0 | 365.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
-1085885649 | 2009-09-10 | Preliminary restoration was completed. | Phone Call | |||
1200044498 | 2008-12-04 | cementing conductor. Good returns to surface. | ||||
1203482542 | 2014-02-20 | The unit is producing with no changes observed since the last inspection. No violations. | ||||
-1497252784 | 2008-12-08 | drilling in shale | ||||
1922538297 | 2010-04-06 | Preliminary restoration was completed. | ||||
1975572914 | 2013-10-09 | The producing unit consists of a wellhead and aboveground storage tank (AST) battery in separate chain-link and board-on-board enclosures, respectively. The wellhead is a mechanical plunger lift unit and is producing. The battery is comprised of 1 210-barrel and 1 140-barrel steel tank and separator. Secondary containment, spacing, and signage is good. Process safety equipment (spark arrestor, carbon filter, and low-pressure relief valve) are present. Gates are locked. No problems noted. | ||||
-314137541 | 2015-04-22 | I inspected this producing unit as part of routine inspection activity. The wellhead is located behind the referenced house on Ravenna Road. The wellhead and battery are located in a mostly wooded area with small clearings for the wellhead and battery. The well is comprised of a mechanical plunger-lift system in a chain-link enclosure. Fittings and connections at the wellhead are secure. The battery is comprised of one 210-barrel steel production tank and one 100-barrel brine tank and separator unit in a separate board-on-board enclosure. Fittings are secure. Load-outs are locked. The containment dike is intact and dry. I walked the areas outside of the wellhead and battery including areas down gradient topographically and did not observe any signs of impact or drainage problems associated with the unit. The access road is unpaved by well drained and passable. | ||||
-318231415 | 2012-11-07 | The unit is comprised of a 2-tank battery (1 210-barrel production tank and 1 100-barrel brine tank) and mechanical separator in an 8-foot wooden enclosure. The wellhead includes a mechanical plunger lift located in a 6-foot wooden enclosure. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination. No violations noted. | ||||
-348662293 | 2008-12-05 | cementing surface. good returns to surface. | ||||
-898871877 | 2011-07-28 | Dike,ID, and spacing in compliance. Vent hatches installed and closed. No fencing. No lighting arrestor or charcoal filter installed. |