34-085-21091

Well Details

Well ID: 34-085-21091
Loading map...
County: Lake
Municipality:
Operator Name: BROAD STREET ENERGY COMPANY
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2004-01-08
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.72837483
Longitude: -81.05679907

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2003-0 0.0 0.0
2004-0 698.0 558.0
2005-0 977.0 309.0
2006-0 689.0 124.0
2007-0 304.0 100.0
2008-0 234.0 110.0
2009-0 192.0 54.0
2010-0 134.0 37.0
2011-0 94.0 0.0
2012-0 224.0 0.0
2013-0 288.0 0.0
2014-0 185.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1049920048 2013-02-11 The producing unit consists of the following: a wellhead with pumpjack system, a 4 tank battery (2 210 barrel, 2 100 barrel), 3 mechanical separators, and associated piping and mechanicals. The tank battery is shared with the #1092 and #0865 units. The tank battery is partially enclosed in a 6-foot chainlink fence. The tank battery secondary containment is adequate. The unit spacing is in accordance with the rule. I did not observe any signs of leaks, releases, or other problems. The unit ID does not indicate permit numbers. There is no ID at the wellhead. I called Matt Sisson and notified him of the need for ID.
-1217164465 2014-03-13 The unit is producing. The unit identification placard is not compliant. The placard at the tank battery is missing the API #s. The placard indicates the Lake County Rod & Gun Club #4 and #5 produce into the battery. Inspection indicates the Klemenc (#20865) is also producing into this battery but not identified. I will contact Broadstreet about adressing the issue.
1469543205 2015-03-25 I inspected this producing well as part of routine inspection activity. The wellhead and are located on a larger farmstead parcel with access via an unpaved, dedicated access road from E. Loveland Road. The road is mostly grown-over with field grass but is passable when dry. The wellhead is comprised of a pump jack system. Fittings and connections are secure. The tank battery is comprised of 1 210-barrel steel production tanks, 2 100-barrel steel brine tanks and 3 separator units. The battery is shared with the #2-0865 and the #2-1092 wells. Elements of the system are aged and show some signs of minor to moderate corrosion but are intact. Fittings and connections are secure and free from signs of leakage at the time of this inspection. The load-outs are plugged and secure. ID signage and secondary containment are present. Areas surrounding the wellhead and battery are reasonably well drained and free from signs of adverse impact from the on-going production activity associated with this well.
-177165220 2013-06-18 The producing unit consists of a wellhead with pump jack and storage tank battery. The wellhead and battery are not enclosed. There is a partially dismantled chain-link enclosure at the battery. The battery is comprised of three above-ground storage tanks (ASTs), 1 140 barrel, 1 100 barrel, and a mechanical separator. The battery is shared with the LC Rod & Gun 5 Unit. The battery is also shared with the Klemenc #1 Unit (20865), but is not identified on the tank battery ID. The tank battery ID is lacking any API #'s. I called the pumper (Ron Slother) and advised him about the need for maintenance.
-729197504 2004-08-19

For data sources see[2]

References

  1. ↑ "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. ↑ "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.