34-105-21995

Well Details

Well ID: 34-105-21995
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1984-02-01
Unconventional:
Horizontal:
Producing: No
Violations: 7
Latitude: 39.0625041824
Longitude: -82.0814807212

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1005487630 2012-09-04 Arrived on location with Josh Garland and Jake Glascock. JD Drilling's Service rig and water truck were on location. They were rigged up waiting on a tool to lift the production tubing packer, R4, to reseat it before the mechanical integrity test was performed. According to Josh they have already tried once on an earlier date to conduct this test and it did not pass. Annular space was already loaded with fresh water on top of the packer before we arrived. Josh put his 1000 psi gauge on the annular space and they used air pressure to raise pressure on the water column to 505 psi to start the 15-minute integrity test. At the end of the test, the well pressure measured 481 psi and met compliance by 1.25 psi ( 505 X .95 = 479.75 psi & 481 - 479.75= 1.25 psi). Josh then measured the injection pressure at 0 psi.
-1005578184 2007-07-17 No violations were found at the time of inspection.
-1014963371 2009-05-05 There were no violations.
-101730823 2013-07-23 Mechanical integrity test of the annulus. Filled annulus with 30 gallons fresh water. Test was attempted multiple times. Unable to pass the test. Each time annulus leaked off more than 5 % in 15 minutes. Well master valve on the injection tubing is closed. Electric to the injection pump has been shut off. A random brine sample was collected and sent to the lab. Injection tubing was on vacuum during the testing of the annulus.
-107393345 2007-10-22 There were no violations at the time.
-1140019584 2012-05-04 Injection tubing and Annulus were both on vacuum. Mechanical Integrity Test Shall be performed. Well shall cease injection operations immediately. 9-5-10(H)
-116772739 2009-03-17 Unable to gauge the annulus pressure. There were no violations at the time of inspection.
-1209101016 2012-10-04 Inspector Jon Scott had cited JD Drilling for cracks in the dike needing to be sealed on 8/5/11. The cracks have been sealed. I also checked the pressures on the injection tubing and the annulus.
-1330542990 2004-05-03 Unable to measure the pressure on the tubing, because the valve is corroded shut. 9-5-09(A)(3)
-1390339643 2013-01-18 No violations.
-1454907603 2014-06-17 Lease road has been graded and gravel has been applied to 3/4 of the road. The lease road is still in use for production wells on the lease. The concrete containment dike, one 100 barrel steel tank, injection pump, lines, and electric service has not been removed. I called Spence Carpenter and Spence told me that they are not sure if they are going to remove the containment dike or reuse the dike and tank for production on the lease. I told Spence that He needs to remove the dike and equipment or submit a waiver form to the UIC section.
-1595126566 2014-01-02 Meeting at JD Drilling office with Spence Carpenter (JD Drilling), and Inspector Josh Garland. We discussed the plans for getting the well in compliance. Spence told us that the plan is to rebuild the R4 packer and install it with a string of new tubing some time next week between 6th and 10th of January 2014. Weather permitting.
-16800175 2004-02-05 Pressures were measured, while the pump was off.
-1683044888 2004-07-20 The previous violation of tubing/fitting requirements has been remedied. A new valve and gauge have been installed on the tubing. Unable to remove pressure gauge, on the tubing, with an adjustable wrench. This gauge is showing a pressure of 0 psi., however this may actually be a vacuum.
-1687047299 2007-02-16 Liner will need replaced.
-1770751467 2012-05-07 Annulus is on vacuum. Filled annulus with 15 barrels fresh water and inhibitor, and attempted to test. Unable to pressure up on annulus. Spence Carpenter said it could be up to two months before they could get a rig on the well to pull the tubing and packer. Injection is shut down.
-17872069 2013-07-23 Follow up to -2075986878. Roughly 30 gallons of fresh water used to fill the annular space. Multiple MIT tests were performed, the well was unable to hold the required pressures for the allowed times. Further remedial actions will be taken and well will remain shut in untill mechanical integrity is proven.
-1879729485 2013-06-06 No violations.
-1897236552 2005-06-16 Upon arrival, the pump was not operating and there was no pressure on the tubing.

Attempted to increase the annular pressure. However, the pressure would not exceed 80 psi.. Instructed the well owner's representative (Spencer Carpenter) to shut down the operation and requested a suspension order.

-2075986878 2013-07-17 The injection tubing was on vacuum. Gauges read no pressure on the annular space, but after opening the needle valve it was noticed the annular space was full of pressurized gas, not fluid. Pressure differential exists between injection tubing and annular space, mechanical integrtiy is still intact. However annular space should be full of fluid. 9-3-07(H)
-466558000 2011-03-08 1.5' water in dike. Water level is over the lower portion of the pump wheel. Pumper was on site pumping out water into tank when I arrived on location. Pump failed and allowed rain event to fill dike. I was unable to test well due to water level in dike. I called Jonathan Reese and talked to him about the pump.
-482192148 2010-03-18 Id on tank. Water in dike. 10" I called pumper and he came to site and turned on the sump pump to drain the dike.
-598432561 2004-04-08 Bad valve on tubing.
-614040655 2006-10-17 No violations. Accompanied by Jon Scott.
-715095397 2012-08-31 10-12 gallons of fresh water were used to fill the annular space. A fresh water mechanical integrity test was administered to attempt to prove mechanical integrity. The test was administered three times, each time the annular space was unable to hold pressure for the required times. The well was shut in.
-756312217 2006-03-29 Pressures were measured while the pump was off.
-778393604 2009-08-18 Good id. Concrete dike needs patched. I informed Spence Carpenter.
-787117375 2007-04-04 Concrete dike was completed. Dimensions were measured at 43 by 24 feet.

Both tanks (400 and 100 bbl.) were set. All was according to the approved plan.

-791723429 2004-10-08 There were no violations at the time of inspection.
-944743234 2006-05-17 There were no violations.
-965405149 2004-03-09 Dike full of water. Notified operator.
1113347954 2005-05-13 9-5-09(A)(3)
1131384446 2005-10-26 Overall findings were acceptable.
116357224 2008-08-22 No violations were found at the time of inspection.
1172314155 2007-04-18 Facility construction was completed. The area around the well site will require seed and mulch.
1189433151 2007-09-10 No violations were found.
1202734941 2008-06-02 No violations were found at the time of inspection.
1212214396 2009-11-24 Good identification. Well is in compliance.
1311950937 2012-06-11 Injection tubing and annulus have communication. Company attempting to reset packer with service rig. Was unable to fill annulus with fresh water and inhibitor. Pulled tubing and packer. 20th tubing joint had holes in side of tubing. Pulled packer out.
1319554638 2011-10-25 Concrete dike cracks have been sealed. No violations observed during inspection.
1339444875 2012-06-11 Packer was released and then reset two feet higher. Freshwater and corrosion inhibitor was placed in the annular space above the packer. When pressurized water flowed out of the tubing. Tubing was pulled and a large hole was found in one of the joints.
1386926567 2012-09-04 Administered fresh water Mechanical Integrity Test. Less than 5 gallons fresh water used to fill the annular space. Annular space was able to hold the required pressure with the allowed decrease in psi for the test period.
1387301668 2013-12-17 Follow up to -2075986878. Well has been shut in since last inspection 7/17/13. Haliburton R4 packer is currently set under tension at 1629 feet on 2 3/8" tubing inside 4 1/2" casing. 17.1 Barrels (Bbl) required to fill annular space. 1.3 gallons corrosion inhibitor mixed with 3 Bbl fresh water was used to top off annulus. Company pulled up to 10,500 lbs on packer and tested annulus three times, each test resulted in a failure to demonstrat Mechanical Integrity. Company pulled up to 19,000 lbs on packer and tested a fourth time, resulting in failure. Company unseated packer and reset at 1628 then tested a fifth time. The company was unable to pass the test.
1387386870 2013-12-18 Follow up to -2075986878. Testing yesterday indicated possible lek in tubing high in hole. Pulled 5 joints of 2 3/8" tubing and reset packer. The annular space was filled with fresh water and a Mechanical Integrity Test was performed. Annular space unable to hold pressure. Company will pull another 5 joints and test again.
1387544517 2013-12-17 Mechanical Integrity Test. Added 1 gallon inhibitor and 3 barrels of fresh water to annulus. Pulled additional 3,000 lbs on tubing tension. Tested 3 times each test lost more than 5% in 15 minutes. Pulled more tension for a total of 19,000 lbs. Retest annulus, test lost more than 5% in 15 minutes. Released packer and pulled up 18" and reset the packer with 21,000 lbs. filled annulus with fresh water and inhibitor. Tested the annulus, test failed. Lost more than 5% in 15 minutes.
1387817951 2013-12-23 Follow up to -2075986878. A rebuilt Haliburton R-4 packer was installed and set under tension at 11,000 pounds using the same tubing at 1626 feet. The annular sapce was tested three times and the well was unable to pass any of the MIT tests.
1387824519 2013-12-23 I accompanied Josh Garland to witness JD Drilling reset packer and perform an annular test.
1392754897 2014-02-18 Witnessed new 2 3/8" tubing and a rebuilt Halliburton R-4 packer being installed in the well. Set packer at 1665' and filled annulus with fresh water and inhibitor. Tested annulus 4 times. All lost more than 5% in 15 minutes. Released packer and pulled 2 joints tubing and set packer at 1607' and filled annulus with fresh water and inhibitor. Tested 2 times both lost more than 5% in 15 minutes. Rig pulled more tension on tubing and sheared the pins in the packer. Pulled tubing and packer back out of the well. Company plans to rebuild the packer and also expose the top of the 7" well head to look for any signs of leaks.
1392917453 2014-02-20 Follow up to -2075986878. Packer was set on tubing inside 4 1/2 last night and 570 psi was placed in side annulus according to company. This morning I tested the annulus and recorded 575 psi. Today 10 more joints of tubing ran and packer reset at 1212 feet. A MIT was administered with 550 psi on the anulus. The well was not able to hold pressure and the MIT failed.
1396323234 2013-12-18 Released packer and pulled 5 joints of tubing out of the well. Set packer filled annulus and tested annulus to determine cause of leak. Test failed. Pulled additional 10 joints (15 total) and set packer , filled annulus with fresh water and tested. Test failed. Pulled all tubing and packer out of well.
1398371181 2014-04-24 Plug Job. JD Drilling service rig and water trucks. Formation Cementing. Ran tubing to 1727'. Berea perfs are from 1704' to 1712'. Pumped 25 sacks class A cement with 2% gel and 4% Cacl. Mixed in Cotton seed hulls as lost circulation material. Tag top of 1st plug at 1318'. Attempted to rip 4.5" casing at 1298' and again at 1264' there was no telegraph at surface (holes were cut in 4.5") Pulled up 100' and attempted to find free point, continued at 100' intervals with no success. Free point was established at 272'. Fluid level at approximately 400'. Attempted to circulate water around 4.5" casing to surface. Pumped 50 barrels fresh water with no returns to surface (air could be felt flowing around 4.5" while pumping water). Bullheaded a 500' cement plug down 4.5" from 1298' to 798'. Displaced 13 barrels inside 4.5". Locked in and waited for cement to set. Ripped 4.5" at 375'. Circulate fresh water to surface. Circulated a large amount of sand and small gravel water was a red brown color. Conditioned the well with Super Mud and was able to circulate and free the 4.5" casing. Pump cement plug from 375' to surface (in two stages 1st 200' then 175' to surface). Water circulated and stayed at the surface during the entire process. Cement returns to surface.
1555336820 2007-04-10 No action has taken place since the last inspection.
1722711926 2008-02-25 There were no violations at the time of inspection.
1841817771 2011-08-05 Good Identification. Concrete dike has cracks that need to be filled. Photos were taken. I called Jonathan Reese and he will have the cracks filled next week then call me for re-inspection.
1848304136 2006-12-18 No violations were found at the time.
1863526457 2005-07-19 Performed a mechanical integrity test on the well.
1866627840 2005-01-14 Could not remove the gauge on the tubing.
1898392404 2005-08-02 Making repairs to the pump and dike.
2016226726 2012-06-12 Install new Halliburton R-4 packer on a different string of used tubing. 3 shear pins were installed on packer (19,000 and 20,000). Packer set at 1629' pulled 7500 lbs over string weight to set packer. Fill annulus with fresh water and inhibitor. Test at 495 psi for 15 minutes. Lost 10 psi. Passed test.
2070615580 2006-07-11 There were no violations at the time of inspection.
217052405 2007-04-12 Flow lines were plumbed and buried.
297114270 2008-04-21 There were no violations at the time.
333909462 2014-07-24 Final restoration requirements met. The tanks, lines, and dike are to be left and used as a transfer tank for two other wells on the lease.
404719357 2010-09-27 Brine in dike. 12 inches deep. 100 bbl tank overflowing. Pump has broken belts. Electric lines at the dike are a hazard. Yellow romex # 12 wires are ran through the air and spliced with tape. Power lines run into dike and are exposed to water. Wiring needs to be redone by an licensed Electrician. Swedge is leaking brine and has been covered with a rag. Replace all leaking fittings and pump out dike into tank. Identification is not legible. Well must have identification: Well owner, lease name, well number, permit number, county, emergency telephone number. 9-5-10(H)
404719357 2010-09-27 Brine in dike. 12 inches deep. 100 bbl tank overflowing. Pump has broken belts. Electric lines at the dike are a hazard. Yellow romex # 12 wires are ran through the air and spliced with tape. Power lines run into dike and are exposed to water. Wiring needs to be redone by an licensed Electrician. Swedge is leaking brine and has been covered with a rag. Replace all leaking fittings and pump out dike into tank. Identification is not legible. Well must have identification: Well owner, lease name, well number, permit number, county, emergency telephone number. NONE(H)
508593066 2011-03-30 Dike is free of water.
573965713 2004-08-17 No violations.
621678957 2008-09-11 There were no violations found at the time of inspection.
628429454 2003-08-14 No violations at the time of inspection.
65299480 2005-07-18 Witnessed the packer installation.
657333446 2007-06-04 There were no violations at the time of inspection.
673232016 2012-05-07 Administered Mechanical Integrity Test with Jon Scott. 15-18 Barrels of fresh water run down annulus. Unable to pressure up on annular space. Test Failed.
706649979 2013-12-19 Well is shut in. Rebuilding packer.
71815089 2006-01-10 No violations at the time.
73686839 2011-10-25 Accompanied J. Scott on SWIW inspection. No violations.
762638953 2003-02-26
776235991 2012-08-22 Upon inspection it was noted the injection tubing and the annular space were both on vacuum. Injection operations shall cease immediately and a mechanical integrity test shall be performed. 9-5-10(H)
840121334 2012-08-29 I spoke with Spence Carpenter about the companies plans to make corrective actions to the well. he has asked to perform the actions 8/31/12. An extension was granted because the company is currently drilling a new well.
882914956 2010-11-24 Good identification on tank. Rewired pumps and electric box. Removed yellow # 12 Romex wire and replaced with Grey # 12 AWG Type UFB Sunlight Resistant wire. Brine leak is fixed. Dike is free of water.
UIC1802 1999-10-20 1501:9-9-05 (A) (9) DIKE MAINTAINENCE
UIC1803 1999-10-20 1501:9-3-04 DIKE NEEDS EMPTY