X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-129-20157

Well Details

Well ID: 34-129-20157
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1997-02-06
Unconventional:
Horizontal:
Producing: No
Violations: 11
Latitude: 39.788168261
Longitude: -82.8984449887

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1101562881 2011-03-17 - Operator has posted ID at well, sign also posted at tank and unloading pad.

- Annulus pressure 420 injection pressure 0 Vacuum - The week of March 7, 2011 the operator had acidize well, when the service truck enter onto the lease road they drove off of the road and across an agricultural field, their ruts were back bladed with a dozer. It's unknown if there were any field drainage tiles damage. - Tank area - dike has a small amount of water.

-1114350244 2005-08-29 - On site for well conversion to UIC.

- Operator cemented 4-1/2 casing in on 8/24/2005, Halliburton contactor for cement job. - Appalachian Well Service doing bond log on well, witness logging of well, by Jeff Fry, Bob Master, and myself. Phone call to Tom Tomastik to approve cement job, cement not at top of requirement on application permit. OK was given, because of the total amount of cement used above the required amount.

-123286240 2005-08-08 - On site for well conversion to UIC well. Bob Master of Cortland Energy Co. contact me at 9:00 AM. Operator unable to get service rig in until next week ( week of 9-15-2005)
-1247131704 2005-11-17 Injection on vacuum, annulus has 0 pressure. Dike 1/3 full of water.

- Phone call to Bob Master and left message, and met with Bob Atha and ask to have well pressure by next week and to pump out dike area.

-12771364 2005-10-04 - Water tank has been set in place, dike is completed. Water line lay to injection well, but not connected to tank.

- Operator still needs to install reducer and fitting for pressure gauge.

-1482888133 2013-10-23 - ID on well, tank battery area and at the unloading pad. Dike area has some water in it due to recent rain fall.

- Injection pressure 0 vacuum, annulus pressure 460 water meter reading 479301 gallons = 11,411 barrels. Unloading vault about 1/2 of water.

-1595224255 2007-04-11 - ID on well and tank. Well injection 0 (vacuum) annulus 240 PSI Water meter reading 552140 gallons = 13,146 barrels Dike has small amount of water.
-1709295524 2013-01-17 - ID on well and tank, dike area has water in it. Unloading pad free of water and debris, unloading vault has been pumped out.

- Annulus pressure 500 Injection pressure 0 on vacuum water meter reading 560763 gallons = 13,351 barrels - Weather condition cloudy temp 30

-1755565710 2009-06-10 - Injection pressure 0 / on vacuum, injection pump operating. Annulus pressure 500 psi. ID posted at well no sign on tank contacted operator and request new sign to be posted at tank. Unloading pad free of water, Vault has a small amount of fluid in it. Water meter reading 19304 gal. = 459barrels
-1762344688 2012-08-08 - ID on well and tank, Dike area free of water. Unloading pad free of water and debris. Unloading pad vault has some water in it.

- Annulus pressure 580 injection pressure 0 vacuum. Water meter reading 331029 gallons = 7,881 barrels. Flow rate 13.03 gallons.

-1873390939 2009-01-06 - Ball valve broken on annulus side of well, valve has frozen in the past weeks. Small valve on injection unable to open.

- iD at well and tank. - Unloading pad clean of debris.

-19261335 2014-06-03 - On site for UIC inspection, ID on well and tank

- Annulus pressure 500 psi Injection pressure 0 on vacuum - Unloading pad free of debris - Tank dike area has a small amount of water in it. - Weather condition heavy rainfall, windy Temp 74 Wet ground conditions

-47721659 2011-06-29 - ID at well and tank area, Unloading pad free of water, overflow vault full contacted Bob Atha on this matter. Annulus pressure 520 Injection pressure 0 vacuum. Water meter 785555 gallons = 18,703 barrels.
-505501759 2008-12-23 - ID on well and tank. Ball valve broken on annuls where gauge mount for reading, unable to check annulus pressure.

- Dike area has water frozen in it, unable to read water meter. - Mr. Jeff McCray landowner ask if a letter could be sent to operator for repairs to drainage tiles that were damage when water line from tank to well was installed. This has caused damage to other field tiles. Also Mr. McCray want production line from where production tank was located to well remove.

-524833284 2007-06-07 Working on unloading facility. Pad with curb has been poured. Was to Mike Mitchell on setting vault. Per Mike hole was too deep and waiting for contractor to show up later today to fill some of hole in. Checked well pressures.
-52891304 2012-06-14 - ID at well and tank. Dike area free of water and debris. Unloading pad clean, overflow vault about half full of water.

- Annulus pressure 540 PSI injection 0 on vacuum water meter reading 234015 gallons flow rate 18 gpm.

-544219635 2013-07-03 - ID at well and tank, Annulus pressure 520 Injection pressure 0

- Water meter reading 247992 gallons = 5,904 barrels - unloading pad vault is about 1/2 full of water.

-750792555 2006-10-26 - ID on well and tank.

- Injection on vacuum, annulus 280 psi. - Water meter 341537 gallons = 8,131 barrels

-877425916 2008-06-11 - No ID at well or tank, contacted Bob Atha.

- Annuls 600 psi injection 0 on vacuum. Water meter 394965 gallons = 9,403 barrels.

1007953166 2010-01-05 - ID at well and tank, Annulus pressure 380 injection 0 on vacuum. Debris at well area.

- Water meter reading 451398 gallons = 10,747 barrels. Unloading pad vault 1/2 full of water. Small amount of water in dike area. - Weather Condition - Temp 16 ground snow covered.

1036076006 2002-10-31 Inspection conducted at the request of Tom Tomastik UIC section. Review of the well site and production tank battery revealed surrounding area is rolling farm land. Walnut Creek is located to the west of the site and Mud creek to the south. There is no water wells located within a 1000' radius of the location. The lease road leading from Perrill Rd. go past a residence and four (4) out buildings, and is constructed of lime stone and old road materials. WEATHER CONDITIONS: Cloudy and 40 degrees. CC: Tom Tomastik.
1057196202 2003-07-02 - On site for inspection, joint inspection with Jeff Fry, status check of well may be converted into injection well. Well looks capable to produce.
1078930886 2004-03-10 - On site for inspection ID at House.

- Well is shut in all ball valves are closed, pulley are heavy rusted. - Tank area 1 tank valve is closed GPS taken at well and tank. - No ID at well or tank. Well not n production. - Contacted operator on 3/11/2004

9-9-05(A)10
1127223210 2005-09-20 - On site for well construction progress, water line has been laid on top of ground from propose storage tank area to well, line is connected to well.

- Operator will need to install fittings and 1/4" valve to check annuals pressure. - Dike area is being constructed, inspector wasn't notify, call in to Bob Master to question why he didn't notify. - Pump unit has been removed from well area. Operator still needs to clean old production equipment from well area.

1127240890 2005-09-20 - on site for inspection of well, well is producing gas. Tank and separator is northwest of well along Morris Liest Rd. on the east side.

- ID at pumping and tank area. - Operator has filled in pits, pits are mounded up, bentonite still visible, area will need to be regraded for agriculture use. - Will pass preliminary inspection when grading is completed.

1127240890177644 2005-09-20 - on site for inspection of well, well is producing gas. Tank and separator is northwest of well along Morris Liest Rd. on the east side.

- ID at pumping and tank area. - Operator has filled in pits, pits are mounded up, bentonite still visible, area will need to be regraded for agriculture use. - Will pass preliminary inspection when grading is completed.

1129055395 2005-10-06 - On site for testing of pipe line from tank to well.

- Pipeline is SDR 7 2" diameter, operator has 1,350 feet of line laying on top of ground, operator plans trench line in as so as possible. - Test started at 8:27 AM @ 240 PSI 8:32 AM @ 240 PSI 8:39AM @ 240 PSI 8:44 AM @ 240 PSI. - 10/06/2005 pass line test, operator started to inject into well.

1131023795 2005-11-03 - Well has 0 psi on annulus injection 0 psi ( vacuum). Operator has trench in water disposal line from tank to well.

- Tank area grass has vegetated, operator is keeping water pump from dike area.

1133961601 2005-12-07 - Annulus pressure 500 , injection 0 (vacuum) operator still has old pipe fitting and some tubing at well area, will need to remove.

- Tank area, operator has pump water from dike. Water meter reading 3480.11 gal. = 82 barrels - Weather overcast temp. low 20's, ground snow cover.

1136900655 2006-01-10 Injection pressure 0 line in under vacuum annulus 480 pressure.

Water meter 14809 gallons = 325 barrels Dike area has about 4 inches of water in it.

1141739452 2006-03-07 - On site for inspection, Injection on Vacuum annulus 400 psi.

- Water meter 196.20 gallons = 4.6 barrels - Old production line has been removed, still several valves, pipe fitting, and pipe on site. - Temp 30's Sunny

1150290209 2006-06-07 - On site for inspection, ID at well not legible, Annulus pressure 400 injection 0 (vacuum)

- Met with Mr. McCray, he indicated that when water line was laid operator cut two field tiles and never fixed them. - Will request operator to make repairs and move water meter from top of tank.

1165293646 2005-08-17 - Well being converted to UIC well. Joint inspection with Jeff Fry.

- On site, wait for driller to show, drill place jars down well to tag sand. Sand bridge off at 1570' driller leaving to retrieve tubing and supply to drill out sand bridge. Will be back on site 8/18/2005

1176310687 2007-04-11 - Operator has place ID on Tank and well, operator has place ladder at water tank so water meter on be read.
1190295307 2007-09-20 - Inspection of well, well has lost mechanical integrity annulus 0 psi on vacuum, injection 0 psi vacuum Violation code 1501:9-3-07 (H)

- Water meter has been removed. Line at water tank to well has been disconnected. - Contacted operator of violation.

9-3-05[C]
1190895706 2007-09-26 - On site for inspection of well service, no rig on site. Call service company. Killbarger service company change schedule to service well next week.

- Well is out of operating, and will remain out of service until well integrity is comply with.

1191498069 2007-10-03 - 10/01 pull tubing and packer from well, unable to have service truck until Wed. 10/03.

- 10/02 install packer and 5 joints of tubing in well. Power tongs blowed hydraulic hose, shut down for repairs. 10/03 install tubing, Halliburton service truck pumped a total of 33 barrels of fresh water with 5 gallons of inhibitor. Robert Hoffee and Shawn Whitacre Halliburton truck service crew. Chris from Halliburton West Virginia office on site and set Halliburton G-6 packer in compression. Packer set at 2652' at GL, 2646 tubing tally plus 6' for sub. Packer had 25,000 lbs of string weight pulled on it after it was set, pressure released and tubing weight set on packer of about 11,000 lbs. - Pressure test started at 10:41 AM with 920 PSI on ODNR gauge, tested for 15 minutes with no loss of pressure. Tested passed, bleed pressure down on annulus to about 350 psi,

1200509013 2008-01-16 - ID at well and tank. Annulus pressure 260 psi injection on vaccum. Water meter 159926 gallons = 3807 barrels
1221502404 2008-09-10 - Inspection of well, No ID posted. Must have ID at well and tank.

- Over flow water vault for unloading pad full, needs to be pumped. - Liner for dike area needs to be repaired, liner sliding down. - Water meter inoperable. - Injection pressure 0 psi on vaccum, Annulus 600 ps

9-3-06(G)
1221502404 2008-09-10 - Inspection of well, No ID posted. Must have ID at well and tank.

- Over flow water vault for unloading pad full, needs to be pumped. - Liner for dike area needs to be repaired, liner sliding down. - Water meter inoperable. - Injection pressure 0 psi on vaccum, Annulus 600 ps

9-3-07(E)
1221502404 2008-09-10 - Inspection of well, No ID posted. Must have ID at well and tank.

- Over flow water vault for unloading pad full, needs to be pumped. - Liner for dike area needs to be repaired, liner sliding down. - Water meter inoperable. - Injection pressure 0 psi on vaccum, Annulus 600 ps

9-3-08(A)
1223383047 2008-10-07 - Follow up inspection to NOV

1. Operator has posted ID at well and on water tank. 2. Dike liner has been repaired, operator has pulled liner back on top of dike and relined outside berm. 3. Water meter repaired 4. Unloading pad vault pumped down and inlet pipe seal repaired, area around vault cleaned. Annulus pressure 560 injection 0 on vacuum water meter reading 105761 gallons = 2518 barrels.

1233251426 2012-09-09 - Joint inspection with Jon Scott of MRM. ID on well and tank. Dike area has some water in it. Unloading pad free of debris, pad vault about 1/3 full of water.

- Annulus pressure 520 injection pressure 0 vacuum water meter reading 385896 gallons = 9,188 barrels.

1238508109 2009-03-31 - Inspection of well. ID at well and tank.

- Well annulus valve has not been replaced, annulus has lost pressure, Injection valve unable to open and install gauge. - Water meter on water tank not operable. - Water in dike area, unloading pad holding water and vault about halve full. - Contacted owner pumper at last inspection about valve needing to be replace. Will contact owner and issue Chief Order to suspend operation.

9-3-05(B)4
1238508109 2009-03-31 - Inspection of well. ID at well and tank.

- Well annulus valve has not been replaced, annulus has lost pressure, Injection valve unable to open and install gauge. - Water meter on water tank not operable. - Water in dike area, unloading pad holding water and vault about halve full. - Contacted owner pumper at last inspection about valve needing to be replace. Will contact owner and issue Chief Order to suspend operation.

9-3-05[C]
1239045325 2009-04-01 - On site for test and repairs to well head. Timco Service Company and Bob Atha on site for repairs.

- Replace 2 inch ball valve on annulus and Small 1/4 inch valve on injection line. Pressure annulus to 480 psi and test well for 15 minutes. Well passed cancel NOV and called Tom Tomastik of repairs and test to well.

1239524538 2008-04-08 - ID on tank and well

- Annulus pressure 0 injection pressure 0 on vacuum. - 2 inch ball valve on annulus broken appears to have frozen. - Contacted Bob Atha on this and he will replace valve and contact me when they pressure annulus back up. - Water meter 303467 gallons = 7,225 barrels

1248i228 2002-02-19 WEATHER CONDITIONS: Cloudy and 45 degrees. Inspection reveled No ID posted at the well head and/or the storage tank. On 01/29/2002 well was transferred from Altheirs Oil, Inc. to Cortland Energy Co., Inc. 9-9-05(A)10
1256645706 2009-10-27 - ID on well, No ID on tank. Injection pump not operating while on site. Annulus pressure 420 injection 0 on vacuum. Water meter 288830 gallons = 6,876 Barrels.

Tank dike has water standing, needs to be pump. - Unloading pad clean of debris, unloading pad vault full of water needs to be pump out.

1283878770 2010-08-10 - New metal ID sign at well location, emergency phone number (614) 436-4813.

- Injection on vacuum, annulus pressure 520 Water meter 224987 gallons = 5,356 barrels. - Unloading pad clean of debris and vault about 1/2 full of water. Water tank about 3/4 full. New sign needed at tank area.

1291658865 2010-12-06 - No ID at well, 1501:9-3-06 (H)

- Annulus pressure 480 injection pressure 260 - Water meter reading 491523 gallons = 11,702 barrels - Dike area has water contained in it, 1501:9-9-05 (A) (9) - plastic liner has slid down on the east end of the dike. 1501:9-3-05 (A) (6) - Unloading pad free of debris and vault about 1/2 full of water - Weather Cloudy Temp 19 frozen ground

9-3-06(G)
1295884888 2011-01-20 - Inspection of well, no ID at well, ID at tank and unloading pad.

- Injection pressure 0 Vacuum, Annulus pressure 460 - Liner has been fix at tank dike, most of the water has been removed from the dike area. - Weather Temp. 20's frozen ground and snow covered. - Contacted Mr. Bob Master that the UIC well need to have ID at the well and tank.

1301156927 2010-06-15 - On site for meeting with landowner Mr. David Strawer, landowner where well is located Mr. Jeff McCray, well owner Mr. Bob Master well caretaker Mr. Bob Atha, ODNR MRM Supervisor Jeff Fry and Mr. Doug Kohli of Pickaway County Soil and Water Conservation District. Mr. McCray has complainted in past years that when Cortland Energy installed the injection line from the tank to the well that several field drainage tiles were cut and not reconnected which has caused several other field tiles to blowout. A site review was conducted and several sink hole and blowout were noted and GPS. The Grass waterway contains the main drainage tile to a small tributary. The repairs may be eligible for a Grant under the Soil and Water Conservation, the cost will be agreed between Cortland Energy and the landowner.
1316622893 2011-09-21 - ID at well and tank, water in dike area.

- Injection pressure 0 Vac. Annulus pressure 500 water meter 938232 gallons = 22,338 barrels. Unloading pad free of water, over flow vault full of water. - Weather condition overcast light rain Temp 70's

1328625815 2012-02-07 - Annulus pressure 440 psi, injection pressure 0 on vacuum. ID at well and tank. Dike area free of water. Unloading pad free of water, unloading pad vault full of water, phone call to owner to have vault pump out.

- Water meter not operable during inspection. - Weather conditions: overcast Temp 30's frozen ground.

1364401320 2013-03-27 - ID at well and tank. Annulus pressure 480 Injection pressure 0 vacuum.

- Water meter reading 43655 gallons = 1,039 barrels. - Unloading pad free of water and debris, unloading pad overflow vault less than half full. - Weather condition partly sunny Temp low 40's

1365304941 2010-03-17 - ID at well and tank. Annulus pressure 420 Injection pressure 0 on Vacuum Water Meter reading 547326 gal. = 13,031 Barrels.

- Unloading pad free of water and debris, vault about I/2 full of water. - Weather Sunny Temp 40's in AM, ground condition wet.

1393520269 2014-02-27 - ID on well and tank.

- Annulus pressure 440 Injection pressure 0 on vacuum - Water meter reading 62724 gallons - Tank entry location 39.78435 -82.89987 - Unloading pad free of water and debris - Weather condition partly cloudy temp 22 ground condition frozen

1556517660 2012-03-20 - On site for inspection of well and tank/dike facility, ID at well and tank. Annulus pressure 500 Injection 0 Vacuum Water Meter 3815 gallons = 90.8 barrels. Vault is about 1/4 full of water.

- The liner on the dike needs to be repaired, photo taken. Will send to operator inspection report and photo.

1742062946 2004-10-12 - On site for inspection, release NOV signs posted at well and tank area. Well area and tank area clean . Well is capable to produce.

- Weather Mid 50' in the AM Sunny.

182374055 2005-08-31 - On site for installing packer and 2-3/8 tubing, witness packer and tubing going into well, check tubing tally. Packer set at 2671 string length.

- Halliburton on site to set packer and to fill annulus with fluid and anhib. - Pressure check well at 900 psi, held pressure for 15 minutes with no loss.

1978940821 2012-09-06 Accompanied Mike Mitchell MRI 3 on inspection of the injection well facilities and checking injection and annulus pressures.
2093719040 2007-06-07 - On site for placement of vault. Operator has dug hole on 6/6, JK Precast set tank into hole, but hole to deep. Tank was set on ground and operator will need to backfill hole.

- Arrive back on site in the afternoon for reset of tank. operator has backfilled hole with crushed limestone, place tank into hole. Seam of tank now above graded. Pipe connected from unloading pad to tank, check pipe for down grade, backfill around pipe. - Photos taken.

326351540 2007-06-06 - ID on well and tank. Injection pressure 0 (vacuum) Annulus pressure 280 water meter reading 639602 gallons = 15,228 barrels.
354708329 2005-02-16 - ID to Jeff McCray property owner.

- Well not operating, gasoline motor locked up. Well valve are open. - Oil truck was on site on 2/15/2005 accordingly by land owner. - Operator has been approved to convert this well to injection well.

436765281 2008-04-22 - inspection of well to check if 2 inch ball valve has been replace. At the time of inspection valve has not been replace, annulus pressure has leaked off because of this broken valve. Injection pressure is on vacuum.
456153229 2007-01-10 - Well injection pressure 0 ( vacuum) annulus pressure 220 ID on well No ID on tank will contact operator. Dike area free of water. Unable to read water meter. Meter is located on top of water tank.

- Landowner question if operator is aloud to bring water from other well and pump into tank for disposal.

9-3-06(G)
667247170 2007-05-31 - Received phone call from Bob Atha today, operator is stating to construct loading / unloading pad for the well. Phone call to Tom Tomastik on condition of well construction to UIC for pad. Pad was listed in UIC permit.

- Operator plans to place form for pad first of next week and to set vault next Wednesday June 6.

757395589 2004-10-12 On site for preliminary inspection, well clear of drilling debris and tank area clear. Preliminary was approved by previous inspector on paper report.
966577825 2005-08-16 - Rig moved on 8/12/2005 operator has dug pit, and rig up. Joint inspection with Jeff Fry.

- Driller putting sand into well to protect injection zone. Wait for sand to settle, operator is leaving to retrieve tools to use tomorrow. Off site at 10:15 AM

CENA998 1999-07-30 1509.12 12