Well ID: 34-105-22738 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.0532160619,"lon":-82.0955970568,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 2006-07-05 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 18 | |
Latitude: 39.0532160619 | |
Longitude: -82.0955970568 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1015311589 | 2006-08-10 | No one on site. | ||||
-1019772435 | 2006-05-17 | The needle valve was replaced. However, the 2 inch valve on the annulus will not open. The dike needs further cleanup. | ||||
-1031969427 | 2004-02-05 | Well pressures were measured just after pump had shut off. No violations at the time of inspection. | ||||
-1134615602 | 2011-10-25 | Accompanied J. Scott on SWIW inspection. No violations, loading pad may need have cement and drain installed. | ||||
-1253271848 | 2003-03-05 | No violations, unable to check pressures need small wrench. | ||||
-1496623811 | 2014-05-20 | Follow up to 935681809. Dike patched. No noted violations. Flow meter read 7256 Barrels at 15 gallons/minutes. | ||||
-1618094538 | 2013-01-18 | Pump running during inspection. The upper dike with the 210 Barrel steel tank is developing small cracks in the bottom. The dike shall be repaired or replaced so that it is water tight. | 9-3-08(A) | |||
-1649795380 | 2012-08-22 | No violations. | ||||
-1680881677 | 2005-06-16 | The owner's representative increased the pressure on the annulus to 1220 psi. The pressures on both sides were monitored for 30 minutes. As the tubing pressure dropped, the annular pressure increased 25 psi. Overall, the well demonstrated mechanical integrity.
(Injection: start 758 psi / stop 738 psi Annulus: start 1220 psi / stop 1245 psi) |
||||
-1685942370 | 2008-12-03 | There were no violations at the time of inspection. | ||||
-1689183921 | 2007-09-10 | There were no violations at the time of inspection. Pump was operating. | ||||
-216142501 | 2005-01-13 | There were no violations at the time of inspection. | ||||
-309365208 | 2013-10-28 | Inspected containment dike, tanks, annulus pressure, injection pressure and injection pump. Dike is free of water. Identification is on tank. | ||||
-314250351 | 2011-03-08 | Dike free of fresh water. | ||||
-403589900 | 2013-07-17 | No violations. | ||||
-458835377 | 2004-07-15 | NOV FOLLOW-UP The well is in noncompliance. The valve on the annulus needs replaced. Spoke with the well tender regarding the required remedy. | ||||
-468537078 | 2014-02-20 | Follow up to 935681809. Dike repairs not made yet. | ||||
-479986209 | 2006-06-27 | The well was in compliance. | ||||
-492626496 | 2006-08-11 | Preformed a mechanical integrity test on the well. Started the test with an annular pressure of 836 psi.. The well passed with a 0.6% loss in pressure, over a 15 minute period. | ||||
-753672285 | 2006-07-31 | |||||
-760721356 | 2008-02-25 | An inspection found that there was no fittings to monitor the annulus pressure. All other conditions were acceptable. | 9-3-07(F) | |||
-895875091 | 2006-03-29 | Oil and water pooling inside the dike. The threads, inside the 1/4 inch needle valve on the backside, were corroded and no longer operational. | 9-3-04(A) | |||
-895875091 | 2006-03-29 | Oil and water pooling inside the dike. The threads, inside the 1/4 inch needle valve on the backside, were corroded and no longer operational. | 9-3-05(A)3 | |||
-954425920 | 2006-07-14 | No one onsite. | ||||
-954425920193713 | 2006-07-14 | No one onsite. | ||||
-954425920196463 | 2006-07-14 | No one onsite. | ||||
-966095518 | 2005-05-06 | Measured pressures while pump was off. The well was pumping at 830 psi.. | 9-3-04(A) | |||
-966095518 | 2005-05-06 | Measured pressures while pump was off. The well was pumping at 830 psi.. | 9-3-05(B)4 | |||
-966095518 | 2005-05-06 | Measured pressures while pump was off. The well was pumping at 830 psi.. | 9-3-07(G) | |||
-97918536 | 2007-02-16 | There were no violations at the time of inspection. | ||||
-985386220 | 2003-07-11 | FOLLOW UP TO NOV # 1058282884 An inspection of the well site revealed the following:
A storage tank was leaking a stream of brine. The dike was half full of brine. There were several cracks in the dike walls. The two 1/4 inch valves on the well were inoperative. R |
9-9-05(A)9 | |||
-985386220 | 2003-07-11 | FOLLOW UP TO NOV # 1058282884 An inspection of the well site revealed the following:
A storage tank was leaking a stream of brine. The dike was half full of brine. There were several cracks in the dike walls. The two 1/4 inch valves on the well were inoperative. R |
NONE(B) | |||
1009030321 | 2009-11-24 | Has identification. No violations observed during inspection. | ||||
1013875276 | 2011-08-24 | Water truck on site. | ||||
1051658233 | 2007-06-04 | No violations were found at the time. | ||||
1058282884 | 2003-07-11 | An inspection of the well site revealed the following:
A storage tank was leaking a stream of brine. The dike was half full of brine. There were several cracks in the dike walls. The two 1/4 inch valves on the well were inoperative. Repair or replace leaking storage tank. Remove brine and oil from inside the dike. Seal cracks in order to make the dike watertight. Repair or replace the valves to allow monitoring. |
9-9-05(A)9 | |||
1058282884 | 2003-07-11 | An inspection of the well site revealed the following:
A storage tank was leaking a stream of brine. The dike was half full of brine. There were several cracks in the dike walls. The two 1/4 inch valves on the well were inoperative. Repair or replace leaking storage tank. Remove brine and oil from inside the dike. Seal cracks in order to make the dike watertight. Repair or replace the valves to allow monitoring. |
NONE(B) | |||
1132155442 | 2005-11-15 | Unable to screw gauge into the needle valve on annulus. | 9-3-05(B)4 | |||
1159462003 | 2006-09-28 | Plumbing in the flow lines. | ||||
1166557908 | 2006-12-18 | The pressures were measured, while the pump was operating. | ||||
1186407148 | 2007-04-12 | No violations were found. | ||||
1223813687 | 2004-07-20 | NOV FOLLOW-UP The well has a new needle valve, on the annulus. The dike will require some clean-up work. | ||||
1260645893 | 2009-03-11 | The two inch annulus valve froze and broke. Therefore, the annulus pressure was not gauged. | ||||
1279819432 | 2010-07-14 | Pump is dripping. 2" steel line is leaking between 90 and hammer union. I have talked to Jonathan Reese and it will be repaired next week. Parts have to be ordered. All brine drips are being contained with in the dike. | 9-3-07(H) | |||
1313315948 | 2010-09-27 | New 2" pipe from the union to "flex" line has multiple leaks. One major leak is on the welded 90 ELL. The Other major leak has a rag (held in place with black tape) covering the leak. The leaks must be fixed. All materials used on the line must be able to with stand the max injection pressures of 1245 psi. Please provide documentation on the "flex stainless steel line" as to pressure rating. | 9-3-07(H) | |||
1391522268 | 2014-02-04 | Follow up to 935681809. Unable to verify dike repairs due to frozen conditions. No noted violations, pump running at time of inspection. | ||||
1406232116 | 2014-07-24 | No noted violations. | ||||
1440344665 | 2009-06-08 | There were no violations at the time. | ||||
1484468400 | 2004-04-08 | Bad valve on annulus. | ||||
1488255564 | 2008-06-02 | There were no violations found at the time of inspection. | ||||
1574195057 | 2013-11-26 | Accompanied Inspector Josh Garland on inspection. He checked pressures on the well. Water was flowing into tank battery containment via a crack in the concrete. The pumper stopped by and we talked with him about repair options. | ||||
1621905531 | 2010-09-30 | Replaced leaking fittings and pipe with yellow flex pipe. Writing on side of yellow flex pipe is: 4805 wire air 600 psi wp 40 bar. No leaks observed. | ||||
162411494 | 2006-09-12 | Old tanks and concrete dike have been removed. Approximately half the site was graded. Upper concrete pad was constructed with a new 210 bbl tank in place. Work on hold due to rain. | ||||
1681259005 | 2006-10-04 | Surface facility construction was complete. | ||||
1723700535 | 2013-12-19 | Inspected the containment dike, tanks, injection pump, injection line, injection pressure, and annulus pressure. Identification is posted on the 1st tank. Dike is free of water. | ||||
1752871480 | 2006-09-21 | Concrete dike completed. In the process of setting the tanks (a 210 bbl knockout, two 210 bbl brine tanks and one 100 bbl oil tank.) | ||||
184754198 | 2006-08-03 | Witnessed a cement squeeze job on the 4 1/2 inch casing. Wiper plug sent to 2630 feet. | ||||
1847702381 | 2011-08-09 | Vegetation reestablished, no erosion, no drilling equipment, good ID. PR passed. | ||||
1902001620 | 2013-04-08 | Inspected containment dike, injection pressure and annulus pressure. Good identification on tank. Dike is free of water. | ||||
2018145642 | 2006-07-27 | Tested the well (bottom plug) with 1810 psi. on the 4 1/2 inch casing. The well passed, losing 5 psi. total over a 15 minutes period. | ||||
2025019888 | 2004-05-03 | Unable to measure the pressure on the annulus, because the valve is corroded shut. | 9-3-05(A)3 | |||
2025019888 | 2004-05-03 | Unable to measure the pressure on the annulus, because the valve is corroded shut. | 9-3-07(F) | |||
208058352 | 2005-07-28 | Oil and water inside dike. Notified the operator that the dike needed cleaned-up. | ||||
2083295145 | 2006-10-18 | No violations at the time. Spoke with Spence Carpenter, regarding the rainwater run-off. | ||||
26148579 | 2006-07-11 | The wire line tool (tubing cutter) got hung inside the tubing and lost at approximately 1120 feet. The job was postponed. | ||||
264255952 | 2006-06-14 | No action has been taken to remedy the violations. | ||||
266102610 | 2004-08-17 | Oil pooling inside dike. Notified well tender. | 9-3-04(A) | |||
348166438 | 2007-07-17 | No violations were found at the time of inspection. | ||||
34888376 | 2006-06-30 | Pumped cement plug through the tubing into the injection zone. | ||||
405495453 | 2010-11-24 | Dike is free of water. New injection line connections are not leaking. | ||||
434129276 | 2006-08-30 | Work on the surface facility progressing. | ||||
447604848 | 2006-10-17 | No violations. Accompanied by Jon Scott. | ||||
532289267 | 2006-07-26 | Completed the plug-back of the well. | ||||
546468863 | 2006-09-07 | Work on the surface facility progressing. | ||||
560004650 | 2008-09-11 | No violations were found at the time of inspection. | ||||
584938746 | 2010-03-18 | Good identification. Dike is clean with no water in it. | ||||
586316528 | 2008-04-21 | There were no violations at the time at the time of inspection. | ||||
606662405 | 2007-10-22 | There were no violations. | ||||
612619482 | 2006-07-18 | Washing out the tubing (just below 900 feet) in order to retrieve the wire line tool at 1120 feet. | ||||
734557798 | 2013-06-06 | Follow up to -1618094538. The cracks in the dikes have been sealed. | ||||
780271050 | 2012-06-25 | No violations. | ||||
7890950 | 2003-12-04 | No violations at the time of inspection. | ||||
905121282 | 2004-10-08 | There were no violations at the time of inspection. | ||||
908607114 | 2009-08-18 | Good identification. No violations at the time of inspection. | ||||
915878355 | 2008-11-06 | Notified the well tender that the gauge on the annulus was started to round-off. | ||||
935681809 | 2013-11-26 | Flow meter at well read 2242 Barrels. A small crack was noticed in the dike and water was flowing into dike. Dike shall be repaired or replaced in order to be water tight. Spoke with field manager on site and discussed repairs. | 9-3-08(A) | |||
994581678 | 2011-10-25 | No violations observed during inspection. | ||||
UIC119 | 1987-03-09 | 1501:9-3-07(E)&(F) |