X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-029-20358"

m
m
 
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-029-20358
 
| Well ID: 34-029-20358
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.785606694, -81.02549624 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.78, -81.02 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 29: Line 29:
 
| Final Drill Date: 1951-10-26
 
| Final Drill Date: 1951-10-26
 
|-
 
|-
| Well Total Depth: 858 ft
+
| Well Total Depth: 858.00 ft
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Latitude: 40.785606694
+
| Latitude: 40.780000
 
|-
 
|-
| Longitude: -81.02549624
+
| Longitude: -81.020000
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
 
  | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 
  | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Well History ==
 
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 93: Line 93:
 
  | title = Risk Based Data Management System - Well and WellHistry Tables
 
  | title = Risk Based Data Management System - Well and WellHistry Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2019-05-07
+
  | date = 2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
<!--== Perforation Treatments ==
 
<!--== Perforation Treatments ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 149: Line 149:
 
| 2014
 
| 2014
 
| [[FOLTZ & FOLTZ LTD PARTNERSHIP]]
 
| [[FOLTZ & FOLTZ LTD PARTNERSHIP]]
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 365
 
| style="text-align: right;" | 365
 
|-
 
|-
 
| 2015
 
| 2015
 
| [[FOLTZ & FOLTZ LTD PARTNERSHIP]]
 
| [[FOLTZ & FOLTZ LTD PARTNERSHIP]]
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 365
 
| style="text-align: right;" | 365
 
|-
 
|-
 
| 2016
 
| 2016
 
| [[FOLTZ & FOLTZ LTD PARTNERSHIP]]
 
| [[FOLTZ & FOLTZ LTD PARTNERSHIP]]
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 365
 
| style="text-align: right;" | 365
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[FOLTZ & FOLTZ LTD PARTNERSHIP]]
 
| [[FOLTZ & FOLTZ LTD PARTNERSHIP]]
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
| style="text-align: right;" | 0
+
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 365
 
| style="text-align: right;" | 365
 
|-
 
|-
Line 175: Line 175:
 
  | title = Risk Based Data Management System - Production Table - Oil and Gas Data
 
  | title = Risk Based Data Management System - Production Table - Oil and Gas Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
<ref>{{cite web
 
<ref>{{cite web
 
  | title = Combined Production - Oil and Gas Data
 
  | title = Combined Production - Oil and Gas Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2019-05-07
+
  | date = 2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable"
 
{| class="wikitable sortable"
Line 220: Line 220:
 
  | title = Risk Based Data Management System - Production Table - Brine Data
 
  | title = Risk Based Data Management System - Production Table - Brine Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
<ref>{{cite web
 
<ref>{{cite web
 
  | title = Combined Production - Brine Data
 
  | title = Combined Production - Brine Data
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2019-05-07
+
  | date = 2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 
==== Inspections Performed ====
 
==== Inspections Performed ====
Line 237: Line 237:
 
!scope="col" style="text-align: center"| Inspection Result
 
!scope="col" style="text-align: center"| Inspection Result
 
!scope="col" style="text-align: center"| Inspection Comments
 
!scope="col" style="text-align: center"| Inspection Comments
 +
|-
 +
| -157819360
 +
| 2017-9-19 0:00:
 +
| PB
 +
| No Violations
 +
| 11.00
 +
|-
 +
| -500271752
 +
| 2005-7-5 0:00:0
 +
| PB
 +
| No Violations
 +
| 1.00
 +
|-
 +
| -966987525
 +
| 2017-9-18 0:00:
 +
| PB
 +
| No Violations
 +
| 6.00
 
|-
 
|-
 
| 0157819360
 
| 0157819360
Line 281: Line 299:
 
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
 
  |publisher = [[Ohio Department of Natural Resources]]
 
  |publisher = [[Ohio Department of Natural Resources]]
  | date =  2019-05-07
+
  | date =  2020-11-16
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2019-05-21 }}</ref>
+
  | accessdate = 2020-11-16 }}</ref>
 
==References==
 
==References==
 
<references/>
 
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Ohio Wells]]
 
[[Category:Ohio Wells]]

Latest revision as of 17:18, 11 January 2021

Well Details

Well ID: 34-029-20358
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: West Township
Operator Name: FOLTZ & FOLTZ LTD PARTNERSHIP
Well Pad ID:
Farm/Lease Name: SANOR DELMAR UNIT
License Status: Final Restoration
License Date: 2017-09-11
Spud Date: 1951-10-08
Spud Drilling Contractor:
Final Drill Date: 1951-10-26
Well Total Depth: 858.00 ft
Configuration: Vertical
Latitude: 40.780000
Longitude: -81.020000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1951-10-08
Completed 1951-10-26
Reached Total Depth 1951-10-26
CO 1977-07-11 475 R & E ENTERPRISES GeoDate 7/11/77
Change of Owner 2004-10-28 Operator changed from 475, R & E ENTERPRISES to 146, FOLTZ & FOLTZ ENTP
APP 2005-05-18 Proposed Formations:BEREA, Issued Date:5/18/2005, Expired Date:5/18/2006 6:00:00 AM, Drilling unit acres:123.85, Proposed Well Type:OG, Proposed Well Class:
APP 2017-09-11 Proposed Formations:BEREA, Issued Date:9/11/2017, Expired Date:9/11/2019 12:00:00 PM, Drilling unit acres:123.85, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2017-09-20
Record Last Modified 2018-06-16
Construction Permit Expires 2019-09-11

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 365
2015 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 365
2016 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 365
2017 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2015 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2016 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2017 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-157819360 2017-9-19 0:00: PB No Violations 11.00
-500271752 2005-7-5 0:00:0 PB No Violations 1.00
-966987525 2017-9-18 0:00: PB No Violations 6.00
0157819360 2017-09-19 Plug / Plug Back No Violations The purpose of my inspection was to witness the plug and abandonment of well #2-0358. Due to fluid conditions in the well, a tremie line of 2steel tubing was placed in the well. Approximately 1.2 yards of 9 sack grout was poured in the annular space of the tremie line followed by additional freshwater to fully displace the plug. After the tremie line stopped flowing, the tremie line was removed and 490 of 4.875 production/intermediate casing was removed from the well. After removing the casing the top of cement was measured at 549. The well remained static. No conductor or drive pipe was present at this location and the 6.25 surface casing remained in place. The well bore volume was calculated and the tremie line re-installed into the well. A total of 4.75 yards of 9 sack grout was ordered and placed in the annular space of the tremie line. The grout was brought to surface and the tremie line was removed and the displaced volume was topped off. The pit maintained free board at the end of the job. I will schedule to witness the top of cement the following day.
0500271752 2005-07-05 Plug / Plug Back No Violations Dropped a weighted line into the hole and stopped at 18. No one present at this time.
0966987525 2017-09-18 Plug / Plug Back No Violations The purpose of my inspection was to witness plug and abandonment activies on well #2-0358. Operator Bob Foltz was on location and removed the rods and tubing. Mr. Foltz measured the static water level at 15 feet below surface and then began to remove fluid from the well. After failing to advance on drying the well up, the decision was made to run tubing back into the well to act as a tremie line to faciliate setting the bottom plug. Fluid removed from the well contained little to no oil and was mostly black colored water. The fluid was transferred to a lined earthen pit that maintained free board. The location remained stable. I will schedule to return to witness the setting of the bottom 9 sack grout plug.
1371659722 2018-06-12 Final Restoration No Violations The purpose of my inspection was to determine the status of final restoration on well #2-0358. At the time of my inspection, the working pit was backfilled and the location graded to local contour. The location was within a woodland. Vegetation was established. No signs of erosion or sedimentation were observed. All equipment and debris utilized in plug and abandonment was removed. The access road was reclaimed. The location has passed the requirements for final restoration.
2103172464 2017-09-20 Plug / Plug Back No Violations The purpose of my inspection was to document the status of second grout plug on well #2-0358. The grout remained at the surface and had not dropped. The location remained stable. The lined earthen pit wsa still holding fluid. No violations were observed during this inspection.

For data sources see[7]