| County: [[Portage_County,_Ohio|Portage]] | | County: [[Portage_County,_Ohio|Portage]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Atwater_Township,_Portage_County,_Ohio|Atwater Township]] |
|- | |- | ||
| Operator Name: [[PEP DRILLING LLC]] | | Operator Name: [[PEP DRILLING LLC]] |
Well ID: 34-133-20227 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.060440374,"lon":-81.18238979,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Portage | |
Municipality: Atwater Township | |
Operator Name: PEP DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: FECUCH P & M | |
License Status: Producing | |
License Date: 1997-07-10 | |
Spud Date: 1963-10-08 | |
Spud Drilling Contractor: | |
Final Drill Date: 1963-10-16 | |
Well Total Depth: 4770 ft | |
Configuration: Vertical | |
Latitude: 41.060440374 | |
Longitude: -81.18238979 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1963-10-08 | |
Completed | 1963-10-16 | |
Reached Total Depth | 1963-10-16 | |
CO | 1990-08-31 | 139 MB OPERATING CO INC |
APP | 1997-07-10 | 139 MB OPERATING CO INC Proposed Formation CLINTON Issued Date 7/10/97 Expired Date 7/10/98 6:00:00 AM |
Change of Owner | 2000-06-30 | Operator changed from 139, MB OPERATING CO INC to 6674, GREAT LAKES ENERGY PTNSHP LLC |
Change of Owner | 2010-04-08 | Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC |
Change of Owner | 2018-11-20 | Operator changed from 7578, ENERVEST OPERATING LLC to 9640, PEP DRILLING LLC |
Record Last Modified | 2018-11-20 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4619 | 4621 | 5 |
2006-09-11 | 4606 | 4608 | 5 |
2006-09-11 | 4638 | 4684 | 93 |
2006-09-11 | 4715 | 4717 | 0 |
2006-09-11 | 4706 | 4708 | 5 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 938 Bbl | 34000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1092051619 | 2018-05-09 | Production Wells | No Violations | Status check inspection of this Clinton Sandstone well. My inspection found the wellhead consisting of 4.5 production casing and set up to operate as an open flow, swab well. The valve on the production casing flow line is currently closed and a gauge indicates a pressure of 350psi on the wellhead. This well produces to a diked and fenced tank battery on location and contains one (1) 100 barrel tank, a 50 barrel poly tank, and a horizontal separator with an associated meter run. There is a domestic tap on the sales line that is not in operation. The required ID is posted on the 100 barrel tank. No violations. |
1268419015 | 2003-09-25 | Production Wells | Violations Noted | The well is still idle. According to John Fleming, Great Lakes intends to pull the rods and tubing and open flow the well. He also acknowledged that the tank battery needs to be rebuilt. This should occur within 60 days. |
1271544242 | 2003-04-01 | Production Wells | Violations Noted | Status check inspection. The pump jack has been removed and the tank battery is in various stages of disassembly. The last reported production from this well was 1999 when the well was operated by MB. It is possible that the well is being used by the landowner. I am waiting for verification from Great Lakes. Otherwise, the well must either be placed back into production or properly plugged and abandoned. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1268419015 | US-OH-107206 | 2003-04-06 | Well shall be plugged | |
1271544242 | US-OH-107567 | 2003-04-06 | Well shall be plugged |
For data sources see[9]