If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 1: | Line 1: | ||
− | __TOC__ | + | __TOC__ |
== Well Details == | == Well Details == | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 34-167-29726 | | Well ID: 34-167-29726 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 39.616418252, -81.41782719 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: | + | | State: Ohio |
+ | |- | ||
+ | | County: [[Washington_County,_Ohio|Washington]] | ||
+ | |- | ||
+ | | Municipality: [[Aurelius_Township,_Washington_County,_Ohio|Aurelius Township]] | ||
|- | |- | ||
| Operator Name: [[TRIAD HUNTER LLC]] | | Operator Name: [[TRIAD HUNTER LLC]] | ||
Line 13: | Line 17: | ||
| Well Pad ID: | | Well Pad ID: | ||
|- | |- | ||
− | | Farm/Lease Name: | + | | Farm/Lease Name: MURPHY WATER SUPPLY WELL |
|- | |- | ||
− | | | + | | License Status: Producing |
|- | |- | ||
− | | | + | | License Date: 2013-06-21 |
|- | |- | ||
| Spud Date: 2013-06-21 | | Spud Date: 2013-06-21 | ||
|- | |- | ||
− | | | + | | Spud Drilling Contractor: [[OTHER]] |
+ | |- | ||
+ | | Final Drill Date: 2013-07-07 | ||
+ | |- | ||
+ | | Well Total Depth: 1550 ft | ||
|- | |- | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | Well Status: Well | + | | Latitude: 39.616418252 |
+ | |- | ||
+ | | Longitude: -81.41782719 | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2019-05-07 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Well Status | ||
+ | !scope="col" style="width: 15%;text-align: center"| Well Status Date | ||
+ | !scope="col" style="text-align: center"| Comment | ||
+ | |- | ||
+ | | APP | ||
+ | | 2013-06-13 | ||
+ | | Proposed Formations:BIG INJUN, Issued Date:6/13/2013, Expired Date:6/13/2015 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OTH, Proposed Well Class:O | ||
+ | |- | ||
+ | | Reached Total Depth | ||
+ | | 2013-07-07 | ||
+ | | | ||
+ | |- | ||
+ | | Completion Report Received | ||
+ | | 2014-01-13 | ||
+ | | | ||
+ | |- | ||
+ | | APP | ||
+ | | 2017-05-09 | ||
+ | | Proposed Formations:BIG INJUN SANDSTONE, Issued Date:5/9/2017, Expired Date:5/9/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:WS, Proposed Well Class:TI | ||
+ | |- | ||
+ | | APP | ||
+ | | 2018-07-11 | ||
+ | | Proposed Formations:BIG INJUN SANDSTONE, Issued Date:7/11/2018, Expired Date:7/10/2020 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:WS, Proposed Well Class: | ||
+ | |- | ||
+ | | Record Last Modified | ||
+ | | 2018-08-24 | ||
+ | | | ||
+ | |- | ||
+ | | Construction Permit Expires | ||
+ | | 2020-07-10 | ||
+ | | | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - Well and WellHistry Tables | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2019-05-07 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | <!--== Perforation Treatments == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Perforation Date | ||
+ | !scope="col" style="text-align: center"| Interval Top (ft) | ||
+ | !scope="col" style="text-align: center"| Interval Base (ft) | ||
+ | !scope="col" style="text-align: center"| Number of Shots | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--== Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Job Number | ||
+ | !scope="col" style="text-align: center"| Job Start Date | ||
+ | !scope="col" style="text-align: center"| Job End Date | ||
+ | !scope="col" style="text-align: center"| True Vertical Depth (ft) | ||
+ | !scope="col" style="text-align: center"| Total Water Volume (gal) | ||
+ | !scope="col" style="text-align: center"| Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" style="width: 100%" | ||
+ | !scope="col" style="text-align: center"| Job Number | ||
+ | !scope="col" style="text-align: center"| Trade Name | ||
+ | !scope="col" style="text-align: center"| Supplier | ||
+ | !scope="col" style="text-align: center"| Purpose | ||
+ | !scope="col" style="text-align: center"| Ingredient Name | ||
+ | !scope="col" style="white-space: nowrap;text-align: center"| CAS Number | ||
+ | !scope="col" style="text-align: center"| Additive Percentage by Mass | ||
+ | !scope="col" style="text-align: center"| Job Percentage by Mass | ||
+ | !scope="col" style="text-align: center"| Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--== Stimulations Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Stimulation Date | ||
+ | !scope="col" style="text-align: center"| Chemical Agent | ||
+ | !scope="col" style="text-align: center"| Chemical Agent Concentration (%) | ||
+ | !scope="col" style="text-align: center"| Fracking Fluid Volume | ||
+ | !scope="col" style="text-align: center"| Mass of Proppant Used (lb) | ||
+ | !scope="col" style="text-align: center"| Fracking Company | ||
+ | !scope="col" style="text-align: center"| Comments | ||
|- | |- | ||
− | | | + | |}--> |
+ | == Production Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Period | ||
+ | !scope="col" style="text-align: center"| Operator Name | ||
+ | !scope="col" style="text-align: center"| Gas Quantity (mcf) | ||
+ | !scope="col" style="text-align: center"| Oil Quantity (bbl) | ||
+ | !scope="col" style="text-align: center"| Production Days | ||
|- | |- | ||
− | | | + | | 2018 |
+ | | [[TRIAD HUNTER LLC]] | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | |} |
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - Production Table - Oil and Gas Data | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2019-05-07 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | <ref>{{cite web | ||
+ | | title = Combined Production - Oil and Gas Data | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2019-05-07 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Waste Data == | ||
+ | {| class="wikitable sortable" | ||
+ | !scope="col" style="text-align: center"| Period | ||
+ | !scope="col" style="text-align: center"| Operator Name | ||
+ | !scope="col" style="text-align: center"| Waste Type | ||
+ | !scope="col" style="text-align: center"| Quantity (bbl) | ||
+ | !scope="col" style="text-align: center"| Production Days | ||
+ | |- | ||
+ | | 2018 | ||
+ | | [[TRIAD HUNTER LLC]] | ||
+ | | Brine | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Risk Based Data Management System - Production Table - Brine Data | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2019-05-07 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | <ref>{{cite web | ||
+ | | title = Combined Production - Brine Data | ||
+ | |publisher = [[Ohio Department of Natural Resources]] | ||
+ | | date = 2019-05-07 | ||
+ | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" style="text-align: center"| Inspection ID |
− | !scope="col" | | + | !scope="col" style="text-align: center"| Inspection Date |
− | !scope="col" | | + | !scope="col" style="text-align: center"| Inspection Type |
− | !scope="col" | + | !scope="col" style="text-align: center"| Inspection Result |
− | + | !scope="col" style="text-align: center"| Inspection Comments | |
− | !scope="col" | + | |- |
− | + | | 0160498910 | |
+ | | 2018-10-22 | ||
+ | | Preliminary Restoration | ||
+ | | No Violations | ||
+ | | According to the last inspection on this well it has been put into the temporary inactive status. I am on location today to complete the preliminary restoration on the well. The restoration meets 1509.072(A) requirements. | ||
+ | |- | ||
+ | | 0650619460 | ||
+ | | 2016-02-11 | ||
+ | | Production Wells | ||
+ | | Violations Noted | ||
+ | | *THIS IS A WATER SUPPLY WELL WHICH WAS USED FOR OIL/GAS WELL DRILLING/COMPLETION.* Upon inspection, it was observed that this well is currently not in production for any type of oilfield water use. Photos were taken of the location. The water well shall be properly plugged and abandoned. Triad Hunter LLC shall submit a written plugging schedule within 30 days to Inspector Lynn Parkins at 5880 Memory Rd. Zanesville, OH 43701 and plug the well within 180 days. Triad Hunter LLC will be notified if the plugging schedule is approved or denied. | ||
+ | |- | ||
+ | | 0744108991 | ||
+ | | 2018-12-19 | ||
+ | | Production Wells | ||
+ | | No Violations | ||
+ | | The well is identified with a metal tag that is stamped. The well was not connected. This well was drilled to provide water in order to complete the wells on the Farley Pad. | ||
|- | |- | ||
| 1173292565 | | 1173292565 | ||
| 2013-07-03 | | 2013-07-03 | ||
− | | | + | | Drill / Deepen / Reopen |
+ | | No Violations | ||
| Witnessed the cementing of the 13.375 casing. Universal did the cementing. Good circulation and good returns were observed at the surface. Mr. Ray Decker and Mr. Sparky Bare were on site. | | Witnessed the cementing of the 13.375 casing. Universal did the cementing. Good circulation and good returns were observed at the surface. Mr. Ray Decker and Mr. Sparky Bare were on site. | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1285088614 |
− | |||
| 2013-08-05 | | 2013-08-05 | ||
− | | | + | | Drill / Deepen / Reopen |
+ | | No Violations | ||
| Company has been pumping water out of this well to use for fracing. They have a mega tank assembled on the pad. It is about 2/3 full. Accompanied on inspection by permitting geologist Rick Cisler, Kenny Brown, and intern Andrew Destocki. | | Company has been pumping water out of this well to use for fracing. They have a mega tank assembled on the pad. It is about 2/3 full. Accompanied on inspection by permitting geologist Rick Cisler, Kenny Brown, and intern Andrew Destocki. | ||
− | |||
− | |||
− | |||
|- | |- | ||
+ | | 1289088289 | ||
+ | | 2016-12-27 | ||
+ | | Administrative Inspection | ||
+ | | No Violations | ||
+ | | Inspection of this well for Temporary Inactive Status found no items on the checklist that would prevent such status being granted. The tank that was on the location was disassembled. Well was disconnected and had a bull plug in place as to prevent any incidents affecting the environment. Good Identification was found at the wellhead. The well site is a large open pad style layout that has gravel. No safety issues were found to be present. At this time no reason is found to not find this well an acceptable candidate for temporary inactive status. | ||
|- | |- | ||
| 1372081252 | | 1372081252 | ||
| 2013-06-22 | | 2013-06-22 | ||
− | | | + | | Casing String Witnessed |
− | | Express energy drill a | + | | No Violations |
− | + | | Express energy drill a 36open hole to 42 and then a 32 on to 100. The rig then installed 26casing at 100lb/ft. Ran to a depth of 100. Mixed 355 sacks of class A cement . Displaced with 55 barrel of fersh water. Good slurry returns. | |
− | |||
− | |||
|- | |- | ||
− | | | + | | 1475387545 |
− | |||
| 2013-07-11 | | 2013-07-11 | ||
− | | | + | | Drill / Deepen / Reopen |
+ | | No Violations | ||
| Rig and support completely moved off of site. Tank battery not constructed yet. Panels are on site and ready to put together for tank battery. New GPS taken at well head. | | Rig and support completely moved off of site. Tank battery not constructed yet. Panels are on site and ready to put together for tank battery. New GPS taken at well head. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1960432084 |
| 2013-06-29 | | 2013-06-29 | ||
− | | | + | | Drill / Deepen / Reopen |
+ | | No Violations | ||
| Witnessed the cementing of the surface casing. 375 feet of 20 inch pipe was ran in 390 feet of 24 inch hole. Good circulation was achieved throughout the whole job. Good returns were observed at the surface. There were no chlorides detected in the mix water. | | Witnessed the cementing of the surface casing. 375 feet of 20 inch pipe was ran in 390 feet of 24 inch hole. Good circulation was achieved throughout the whole job. Good returns were observed at the surface. There were no chlorides detected in the mix water. | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 1987766182 |
− | |||
| 2013-07-02 | | 2013-07-02 | ||
− | | | + | | Drill / Deepen / Reopen |
+ | | No Violations | ||
| Rig was shut down again due to the waste handlers. Depth at the time of inspection was 1080 feet. Spoke with Mr. Ray Decker on site. I tested the mix water for the upcoming cement job. It tested at 5.4 with a low range quantab. That means 336 parts per million chlorides. I notified Mr. Decker of this, and he opted to bring different freshwater haulers and test their water for chlorides. | | Rig was shut down again due to the waste handlers. Depth at the time of inspection was 1080 feet. Spoke with Mr. Ray Decker on site. I tested the mix water for the upcoming cement job. It tested at 5.4 with a low range quantab. That means 336 parts per million chlorides. I notified Mr. Decker of this, and he opted to bring different freshwater haulers and test their water for chlorides. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2020751561 | | 2020751561 | ||
| 2013-06-26 | | 2013-06-26 | ||
− | | | + | | Drill / Deepen / Reopen |
+ | | No Violations | ||
| Rig modifications and repairs were being made at the time of inspection. Spoke with Mr Ray Decker on site. He stated that rig had sat for 6 months and the hoses needed replaced. They also had to plumb everything up for the closed loop system. | | Rig modifications and repairs were being made at the time of inspection. Spoke with Mr Ray Decker on site. He stated that rig had sat for 6 months and the hoses needed replaced. They also had to plumb everything up for the closed loop system. | ||
+ | |- | ||
+ | |} | ||
+ | ==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" style="text-align: center"| Inspection ID | ||
+ | !scope="col" style="text-align: center"| Violation ID | ||
+ | !scope="col" style="text-align: center"| Violation Date | ||
+ | !scope="col" style="text-align: center"| Violation Code | ||
+ | !scope="col" style="text-align: center"| Violation Comments | ||
+ | |- | ||
+ | | 0650619460 | ||
+ | | US-OH-127372 | ||
+ | | 2016-10-20 | ||
| | | | ||
− | | | + | | Well shall be plugged |
− | |||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = | + | | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables |
− | | publisher = [ | + | |publisher = [[Ohio Department of Natural Resources]] |
− | | date = | + | | date = 2019-05-07 |
− | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
− | == References == | + | ==References== |
− | + | <references/> | |
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Ohio Wells]] |
Well ID: 34-167-29726 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.616418252,"lon":-81.41782719,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Aurelius Township | |
Operator Name: TRIAD HUNTER LLC | |
Well Pad ID: | |
Farm/Lease Name: MURPHY WATER SUPPLY WELL | |
License Status: Producing | |
License Date: 2013-06-21 | |
Spud Date: 2013-06-21 | |
Spud Drilling Contractor: OTHER | |
Final Drill Date: 2013-07-07 | |
Well Total Depth: 1550 ft | |
Configuration: Vertical | |
Latitude: 39.616418252 | |
Longitude: -81.41782719 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-06-13 | Proposed Formations:BIG INJUN, Issued Date:6/13/2013, Expired Date:6/13/2015 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OTH, Proposed Well Class:O |
Reached Total Depth | 2013-07-07 | |
Completion Report Received | 2014-01-13 | |
APP | 2017-05-09 | Proposed Formations:BIG INJUN SANDSTONE, Issued Date:5/9/2017, Expired Date:5/9/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:WS, Proposed Well Class:TI |
APP | 2018-07-11 | Proposed Formations:BIG INJUN SANDSTONE, Issued Date:7/11/2018, Expired Date:7/10/2020 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:WS, Proposed Well Class: |
Record Last Modified | 2018-08-24 | |
Construction Permit Expires | 2020-07-10 |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2018 | TRIAD HUNTER LLC | 0 | 0 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2018 | TRIAD HUNTER LLC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0160498910 | 2018-10-22 | Preliminary Restoration | No Violations | According to the last inspection on this well it has been put into the temporary inactive status. I am on location today to complete the preliminary restoration on the well. The restoration meets 1509.072(A) requirements. |
0650619460 | 2016-02-11 | Production Wells | Violations Noted | *THIS IS A WATER SUPPLY WELL WHICH WAS USED FOR OIL/GAS WELL DRILLING/COMPLETION.* Upon inspection, it was observed that this well is currently not in production for any type of oilfield water use. Photos were taken of the location. The water well shall be properly plugged and abandoned. Triad Hunter LLC shall submit a written plugging schedule within 30 days to Inspector Lynn Parkins at 5880 Memory Rd. Zanesville, OH 43701 and plug the well within 180 days. Triad Hunter LLC will be notified if the plugging schedule is approved or denied. |
0744108991 | 2018-12-19 | Production Wells | No Violations | The well is identified with a metal tag that is stamped. The well was not connected. This well was drilled to provide water in order to complete the wells on the Farley Pad. |
1173292565 | 2013-07-03 | Drill / Deepen / Reopen | No Violations | Witnessed the cementing of the 13.375 casing. Universal did the cementing. Good circulation and good returns were observed at the surface. Mr. Ray Decker and Mr. Sparky Bare were on site. |
1285088614 | 2013-08-05 | Drill / Deepen / Reopen | No Violations | Company has been pumping water out of this well to use for fracing. They have a mega tank assembled on the pad. It is about 2/3 full. Accompanied on inspection by permitting geologist Rick Cisler, Kenny Brown, and intern Andrew Destocki. |
1289088289 | 2016-12-27 | Administrative Inspection | No Violations | Inspection of this well for Temporary Inactive Status found no items on the checklist that would prevent such status being granted. The tank that was on the location was disassembled. Well was disconnected and had a bull plug in place as to prevent any incidents affecting the environment. Good Identification was found at the wellhead. The well site is a large open pad style layout that has gravel. No safety issues were found to be present. At this time no reason is found to not find this well an acceptable candidate for temporary inactive status. |
1372081252 | 2013-06-22 | Casing String Witnessed | No Violations | Express energy drill a 36open hole to 42 and then a 32 on to 100. The rig then installed 26casing at 100lb/ft. Ran to a depth of 100. Mixed 355 sacks of class A cement . Displaced with 55 barrel of fersh water. Good slurry returns. |
1475387545 | 2013-07-11 | Drill / Deepen / Reopen | No Violations | Rig and support completely moved off of site. Tank battery not constructed yet. Panels are on site and ready to put together for tank battery. New GPS taken at well head. |
1960432084 | 2013-06-29 | Drill / Deepen / Reopen | No Violations | Witnessed the cementing of the surface casing. 375 feet of 20 inch pipe was ran in 390 feet of 24 inch hole. Good circulation was achieved throughout the whole job. Good returns were observed at the surface. There were no chlorides detected in the mix water. |
1987766182 | 2013-07-02 | Drill / Deepen / Reopen | No Violations | Rig was shut down again due to the waste handlers. Depth at the time of inspection was 1080 feet. Spoke with Mr. Ray Decker on site. I tested the mix water for the upcoming cement job. It tested at 5.4 with a low range quantab. That means 336 parts per million chlorides. I notified Mr. Decker of this, and he opted to bring different freshwater haulers and test their water for chlorides. |
2020751561 | 2013-06-26 | Drill / Deepen / Reopen | No Violations | Rig modifications and repairs were being made at the time of inspection. Spoke with Mr Ray Decker on site. He stated that rig had sat for 6 months and the hoses needed replaced. They also had to plumb everything up for the closed loop system. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0650619460 | US-OH-127372 | 2016-10-20 | Well shall be plugged |
For data sources see[7]